Pulse wave velocity and digital volume pulse as indirect estimators of blood pressure: pilot study on healthy volunteers.

Juan M Padilla, Enrique J Berjano, Javier Sáiz, Rafael Rodriguez, Lorenzo Fácila
{"title":"Pulse wave velocity and digital volume pulse as indirect estimators of blood pressure: pilot study on healthy volunteers.","authors":"Juan M Padilla,&nbsp;Enrique J Berjano,&nbsp;Javier Sáiz,&nbsp;Rafael Rodriguez,&nbsp;Lorenzo Fácila","doi":"10.1007/s10558-009-9080-5","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of the study was to asses the potential use of pulse wave velocity (PWV) and digital volume pulse (DVP) as estimators of systolic (SBP) and diastolic (DPB) blood pressure. Single and multiple correlation studies were conducted, including biometric parameters and risk factors. Brachial-ankle PWV (baPWV) and DVP signals were obtained from a Pulse Trace PWV and Pulse Trace PCA (pulse contour analysis), respectively. The DVP (obtained by photoplethysmography), allowed stiffness (SI) and reflection indexes (RI) to be derived. The first study on 47 healthy volunteers showed that both SBP and DPB correlated significantly both with baPWV and SI. Multiple regression models of the baPWV and the waist-to-hip ratio (WHR) allowed SBP and DBP to be modeled with r = 0.838 and r = 0.673, respectively. SI results also employed WHR and modeled SBP and DBP with r = 0.852 and r = 0.663, respectively. RI did not correlate either with SBP or DBP. In order to avoid the use of ultrasound techniques to measure PWV, we then developed a custom-built system to measure PWV by photoplethysmography and validated it against the Pulse Trace. With the same equipment we conducted a second pilot study with ten healthy volunteers. The best SBP multiple regression model for SBP achieved r = 0.997 by considering the heart-finger PWV (hfPWV measured between R-wave and index finger), WHR and heart rate. Only WHR was significant in the DBP model. Our findings suggest that the hfPWV photoplethysmography signal could be a reliable estimator of approximate SBP and could be used, for example, to monitor cardiac patients during physical exercise sessions in cardiac rehabilitation.</p>","PeriodicalId":55275,"journal":{"name":"Cardiovascular Engineering (dordrecht, Netherlands)","volume":" ","pages":"104-12"},"PeriodicalIF":0.0000,"publicationDate":"2009-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s10558-009-9080-5","citationCount":"23","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Engineering (dordrecht, Netherlands)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10558-009-9080-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2009/8/6 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

Abstract

The purpose of the study was to asses the potential use of pulse wave velocity (PWV) and digital volume pulse (DVP) as estimators of systolic (SBP) and diastolic (DPB) blood pressure. Single and multiple correlation studies were conducted, including biometric parameters and risk factors. Brachial-ankle PWV (baPWV) and DVP signals were obtained from a Pulse Trace PWV and Pulse Trace PCA (pulse contour analysis), respectively. The DVP (obtained by photoplethysmography), allowed stiffness (SI) and reflection indexes (RI) to be derived. The first study on 47 healthy volunteers showed that both SBP and DPB correlated significantly both with baPWV and SI. Multiple regression models of the baPWV and the waist-to-hip ratio (WHR) allowed SBP and DBP to be modeled with r = 0.838 and r = 0.673, respectively. SI results also employed WHR and modeled SBP and DBP with r = 0.852 and r = 0.663, respectively. RI did not correlate either with SBP or DBP. In order to avoid the use of ultrasound techniques to measure PWV, we then developed a custom-built system to measure PWV by photoplethysmography and validated it against the Pulse Trace. With the same equipment we conducted a second pilot study with ten healthy volunteers. The best SBP multiple regression model for SBP achieved r = 0.997 by considering the heart-finger PWV (hfPWV measured between R-wave and index finger), WHR and heart rate. Only WHR was significant in the DBP model. Our findings suggest that the hfPWV photoplethysmography signal could be a reliable estimator of approximate SBP and could be used, for example, to monitor cardiac patients during physical exercise sessions in cardiac rehabilitation.

脉搏波速度和数字容积脉冲作为血压的间接估计:对健康志愿者的初步研究。
该研究的目的是评估脉搏波速度(PWV)和数字体积脉冲(DVP)作为收缩压(SBP)和舒张压(DPB)血压估计值的潜在用途。进行了单因素和多因素相关研究,包括生物特征参数和危险因素。分别通过脉冲跟踪PWV和脉冲跟踪PCA(脉冲轮廓分析)获得肱-踝关节PWV (baPWV)和DVP信号。DVP(通过光体积脉搏图获得)允许导出刚度(SI)和反射指数(RI)。第一项对47名健康志愿者的研究表明,收缩压和DPB与baPWV和SI均显著相关。baPWV和腰臀比(WHR)的多元回归模型使收缩压和舒张压的模型分别为r = 0.838和r = 0.673。SI结果也采用WHR,模型收缩压和舒张压分别为r = 0.852和r = 0.663。RI与收缩压和舒张压均无相关性。为了避免使用超声技术来测量PWV,我们随后开发了一个定制的系统,通过光电体积脉搏波测量PWV,并根据Pulse Trace对其进行验证。我们用同样的设备对10名健康志愿者进行了第二次试点研究。考虑心指PWV (r波与食指之间测量的hfPWV)、WHR和心率,最佳收缩压多元回归模型r = 0.997。在DBP模型中,只有WHR具有显著性。我们的研究结果表明,hfPWV光容积脉搏波信号可能是一个可靠的近似收缩压估计值,可以用于监测心脏康复运动期间的心脏患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信