Cardiac Pacing a Rare Cause of Ventilator Auto Triggering.

IF 1.5
M Nithish Mukunthan, Vimal Bhardwaj
{"title":"Cardiac Pacing a Rare Cause of Ventilator Auto Triggering.","authors":"M Nithish Mukunthan,&nbsp;Vimal Bhardwaj","doi":"10.5005/jp-journals-10071-24219","DOIUrl":null,"url":null,"abstract":"<p><p>Ventilator auto triggering is an avoidable complication in ventilators, if left unnoticed can lead to deleterious effects. There are various causes for ventilator auto triggering. Though rare, there are some cardiac causes for inadvertent ventilator triggering. We report a case of 44-years-old male paced with atrial epicardial wires postcoronary artery bypass. The wires were close to the right phrenic nerve, causing the right diaphragm to contract in synchronization with the heartbeat. This caused ventilator auto triggering and ended up delivering inadvertent breaths. The pacemaker output was immediately reduced to the required minimum to continue pacing the heart and decrease phrenic nerve stimulation. This caused immediate changes in ventilator waveform and auto triggering was completely stopped and the patient could be successfully weaned off the ventilator. This case report emphasizes he need for timely recognition of alteration in ventilator waveforms and early intervention to avert any untoward events.</p><p><strong>How to cite this article: </strong>Mukunthan MN, Bhardwaj V. Cardiac Pacing a Rare Cause of Ventilator Auto Triggering. Indian J Crit Care Med 2022;26(5):643-645.</p>","PeriodicalId":520643,"journal":{"name":"Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine","volume":" ","pages":"643-645"},"PeriodicalIF":1.5000,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/0f/b4/ijccm-26-643.PMC9160607.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/jp-journals-10071-24219","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Ventilator auto triggering is an avoidable complication in ventilators, if left unnoticed can lead to deleterious effects. There are various causes for ventilator auto triggering. Though rare, there are some cardiac causes for inadvertent ventilator triggering. We report a case of 44-years-old male paced with atrial epicardial wires postcoronary artery bypass. The wires were close to the right phrenic nerve, causing the right diaphragm to contract in synchronization with the heartbeat. This caused ventilator auto triggering and ended up delivering inadvertent breaths. The pacemaker output was immediately reduced to the required minimum to continue pacing the heart and decrease phrenic nerve stimulation. This caused immediate changes in ventilator waveform and auto triggering was completely stopped and the patient could be successfully weaned off the ventilator. This case report emphasizes he need for timely recognition of alteration in ventilator waveforms and early intervention to avert any untoward events.

How to cite this article: Mukunthan MN, Bhardwaj V. Cardiac Pacing a Rare Cause of Ventilator Auto Triggering. Indian J Crit Care Med 2022;26(5):643-645.

Abstract Image

Abstract Image

Abstract Image

心脏起搏是呼吸机自动触发的罕见原因。
呼吸机自动触发是呼吸机可避免的并发症,如果不注意可能导致有害影响。通风机自动触发的原因有多种。虽然罕见,但也有一些心脏原因导致误触发呼吸机。我们报告一例44岁男性冠状动脉搭桥术后心房心外膜导线。导线靠近右侧膈神经,导致右侧膈肌与心跳同步收缩。这导致呼吸机自动触发,并最终提供无意的呼吸。起搏器输出立即减少到所需的最小值,以继续心脏起搏并减少膈神经刺激。这导致呼吸机波形立即发生变化,自动触发完全停止,患者可以成功脱离呼吸机。本病例报告强调需要及时识别呼吸机波形的改变和早期干预以避免任何不良事件。Mukunthan MN, Bhardwaj V.心脏起搏是呼吸机自动触发的罕见原因。中华检验医学杂志;2009;26(5):643-645。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信