Comparison of Ex-PRESS implantation versus trabeculectomy combined with phacoemulsification in primary open-angle glaucoma: a retrospective in vivo confocal microscopy study.

Yuqiao Zhang, Beiting He, Yulin Zhang, Jin Zeng, Yanlei Chen, Yongyi Niu, Honghua Yu, Yongjie Qin, Hongyang Zhang
{"title":"Comparison of Ex-PRESS implantation versus trabeculectomy combined with phacoemulsification in primary open-angle glaucoma: a retrospective in vivo confocal microscopy study.","authors":"Yuqiao Zhang,&nbsp;Beiting He,&nbsp;Yulin Zhang,&nbsp;Jin Zeng,&nbsp;Yanlei Chen,&nbsp;Yongyi Niu,&nbsp;Honghua Yu,&nbsp;Yongjie Qin,&nbsp;Hongyang Zhang","doi":"10.1186/s40662-022-00278-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To compare the efficacy of Ex-PRESS implantation versus trabeculectomy combined with phacoemulsification.</p><p><strong>Methods: </strong>A retrospective 12-month study on patients with coincident primary open-angle glaucoma (POAG) and cataract. The patients underwent combined phacoemulsification and Ex-PRESS implant (Phaco-ExPRESS, n = 35) or phacotrabeculectomy (Phaco-Trab, n = 35). The morphological structures of the filtering bleb were examined by slit-lamp, anterior segment optical coherence tomography (AS-OCT) and in vivo confocal microscopy (IVCM). Complete success was defined as postoperative intraocular pressure (IOP) < 18 mmHg without the use of anti-glaucoma medication. Qualified success was defined as postoperative IOP < 18 mmHg with or without anti-glaucoma medications. The data were collected preoperatively and postoperatively at 2 weeks, 1 month, 3 months, 6 months, and 12 months.</p><p><strong>Results: </strong>No significant difference in the variables such as age, IOP and perimetry was found between the groups of Phaco-ExPRESS and Phaco-Trab. At the one-year postoperative visit for filtering blebs, Phaco-ExPRESS increased the mean area of epithelial microcysts significantly from 0.10 ± 0.05 to 0.20 ± 0.09 μm<sup>2</sup> per μm<sup>2</sup>, while Phaco-Trab decreased the mean area significantly from 0.08 ± 0.04 to 0.04 ± 0.06 μm<sup>2</sup> per μm<sup>2</sup>. Notably, the hyperreflective dots detected by IVCM decreased by 84.9% in Phaco-ExPRESS but increased by 36.3% in Phaco-Trab. The hyperreflective dots were further identified as neutrophil- and monocyte-like cells. The number of these cells were negatively correlated with the microcysts area (r =  - 0.7, P < 0.01) but positively associated with the grade of connective tissue (r = 0.5, P < 0.01). By creating different microstructural changes in the filtering blebs, Phaco-ExPRESS produced a higher complete success rate (84.9% vs. 41.2%, P < 0.01) and significant decrease in the number of anti-glaucoma medications (P < 0.01) when compared with those in Phaco-Trab. However, the qualified success showed no significant difference between the two groups (100.0% vs. 91.2%, P = 0.24).</p><p><strong>Conclusions: </strong>At the one-year follow-up, Phaco-ExPRESS generated better filtering bleb with larger area of microcysts, looser connective tissues, and less inflammation than that of Phaco-Trab, providing adequate IOP control and less IOP-lowering medications. These findings indicate that Phaco-ExPRESS could be more preferred than Phaco-Trab for the treatment of patients with coincident POAG and cataract.</p>","PeriodicalId":520624,"journal":{"name":"Eye and vision (London, England)","volume":" ","pages":"7"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8841063/pdf/","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye and vision (London, England)","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40662-022-00278-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Background: To compare the efficacy of Ex-PRESS implantation versus trabeculectomy combined with phacoemulsification.

Methods: A retrospective 12-month study on patients with coincident primary open-angle glaucoma (POAG) and cataract. The patients underwent combined phacoemulsification and Ex-PRESS implant (Phaco-ExPRESS, n = 35) or phacotrabeculectomy (Phaco-Trab, n = 35). The morphological structures of the filtering bleb were examined by slit-lamp, anterior segment optical coherence tomography (AS-OCT) and in vivo confocal microscopy (IVCM). Complete success was defined as postoperative intraocular pressure (IOP) < 18 mmHg without the use of anti-glaucoma medication. Qualified success was defined as postoperative IOP < 18 mmHg with or without anti-glaucoma medications. The data were collected preoperatively and postoperatively at 2 weeks, 1 month, 3 months, 6 months, and 12 months.

Results: No significant difference in the variables such as age, IOP and perimetry was found between the groups of Phaco-ExPRESS and Phaco-Trab. At the one-year postoperative visit for filtering blebs, Phaco-ExPRESS increased the mean area of epithelial microcysts significantly from 0.10 ± 0.05 to 0.20 ± 0.09 μm2 per μm2, while Phaco-Trab decreased the mean area significantly from 0.08 ± 0.04 to 0.04 ± 0.06 μm2 per μm2. Notably, the hyperreflective dots detected by IVCM decreased by 84.9% in Phaco-ExPRESS but increased by 36.3% in Phaco-Trab. The hyperreflective dots were further identified as neutrophil- and monocyte-like cells. The number of these cells were negatively correlated with the microcysts area (r =  - 0.7, P < 0.01) but positively associated with the grade of connective tissue (r = 0.5, P < 0.01). By creating different microstructural changes in the filtering blebs, Phaco-ExPRESS produced a higher complete success rate (84.9% vs. 41.2%, P < 0.01) and significant decrease in the number of anti-glaucoma medications (P < 0.01) when compared with those in Phaco-Trab. However, the qualified success showed no significant difference between the two groups (100.0% vs. 91.2%, P = 0.24).

Conclusions: At the one-year follow-up, Phaco-ExPRESS generated better filtering bleb with larger area of microcysts, looser connective tissues, and less inflammation than that of Phaco-Trab, providing adequate IOP control and less IOP-lowering medications. These findings indicate that Phaco-ExPRESS could be more preferred than Phaco-Trab for the treatment of patients with coincident POAG and cataract.

Abstract Image

Abstract Image

Abstract Image

Ex-PRESS植入术与小梁切除术联合超声乳化术治疗原发性开角型青光眼的比较:回顾性体内共聚焦显微镜研究。
背景:比较Ex-PRESS植入术与小梁切除术联合超声乳化术的疗效。方法:对原发性开角型青光眼合并白内障患者进行为期12个月的回顾性研究。患者行超声乳化联合Ex-PRESS假体(Phaco-ExPRESS, n = 35)或超声小梁切除术(Phaco-Trab, n = 35)。采用裂隙灯、前段光学相干断层扫描(AS-OCT)和体内共聚焦显微镜(IVCM)观察滤泡的形态结构。结果:Phaco-ExPRESS组与Phaco-Trab组在年龄、IOP、视界等指标上无显著差异。在滤过泡术后1年随访时,Phaco-ExPRESS使上皮微囊的平均面积从0.10±0.05显著增加到0.20±0.09 μm2 / μm2, Phaco-Trab使上皮微囊的平均面积从0.08±0.04显著减少到0.04±0.06 μm2 / μm2。值得注意的是,IVCM检测到的高反射点在Phaco-ExPRESS中减少了84.9%,而在Phaco-Trab中增加了36.3%。高反射点进一步被鉴定为中性粒细胞和单核细胞样细胞。这些细胞的数量与微囊面积呈负相关(r = - 0.7, P)。结论:在1年的随访中,Phaco-ExPRESS比Phaco-Trab产生了更好的滤泡,微囊面积更大,结缔组织更疏松,炎症反应更少,提供了充分的IOP控制和更少的降眼压药物。这些结果表明Phaco-ExPRESS比Phaco-Trab更适合POAG合并白内障的患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信