Evaluation of Orthokeratology Lens Fitting Assisted by Sagittal Height Simulation Software.

Zhen Yi, Shen Jing, Wang Wenhua, Li Qian, Wang Ningli
{"title":"Evaluation of Orthokeratology Lens Fitting Assisted by Sagittal Height Simulation Software.","authors":"Zhen Yi,&nbsp;Shen Jing,&nbsp;Wang Wenhua,&nbsp;Li Qian,&nbsp;Wang Ningli","doi":"10.1097/ICL.0000000000000861","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate a novel sagittal height fitting algorithm for estimation of alignment curve (AC) radius during Euclid orthokeratology lens trial.</p><p><strong>Methods: </strong>Chinese myopic children were recruited in this study and were randomly divided into two groups. The AC radius of one group was calculated by the novel fitting algorithm. The AC radius of the other group was decided by the optometrist using flat K readings and eccentricity values. The number of lens trials was recorded for each patient, and the consistencies of AC radius between the first trial lenses and the final ordered lenses were tested by Pearson correlations and Bland-Altman plots.</p><p><strong>Results: </strong>One hundred three adolescent patients (103 eyes) were enrolled, including 57 boys and 46 girls. The numbers of trials for the novel algorithm and traditional method were 1.2±0.4 times versus 1.4±0.5 times, respectively, and the difference between the two methods was significant (t=2.404, P=0.018). The difference of AC value between the first trial lens and the lens to be produced for the novel algorithm and traditional method 0.000±0.020 mm and 0.003±0.028 mm separately. There was no statistical difference between the two methods (t=0.748, P=0.456).</p><p><strong>Conclusions: </strong>The new sagittal height simulation software can accurately calculate the AC value of the orthokeratology lens suitable for the Chinese patients.</p>","PeriodicalId":502139,"journal":{"name":"Eye & Contact Lens","volume":" ","pages":"78-82"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000000861","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To evaluate a novel sagittal height fitting algorithm for estimation of alignment curve (AC) radius during Euclid orthokeratology lens trial.

Methods: Chinese myopic children were recruited in this study and were randomly divided into two groups. The AC radius of one group was calculated by the novel fitting algorithm. The AC radius of the other group was decided by the optometrist using flat K readings and eccentricity values. The number of lens trials was recorded for each patient, and the consistencies of AC radius between the first trial lenses and the final ordered lenses were tested by Pearson correlations and Bland-Altman plots.

Results: One hundred three adolescent patients (103 eyes) were enrolled, including 57 boys and 46 girls. The numbers of trials for the novel algorithm and traditional method were 1.2±0.4 times versus 1.4±0.5 times, respectively, and the difference between the two methods was significant (t=2.404, P=0.018). The difference of AC value between the first trial lens and the lens to be produced for the novel algorithm and traditional method 0.000±0.020 mm and 0.003±0.028 mm separately. There was no statistical difference between the two methods (t=0.748, P=0.456).

Conclusions: The new sagittal height simulation software can accurately calculate the AC value of the orthokeratology lens suitable for the Chinese patients.

矢状面高度模拟软件辅助角膜塑形镜配合术的评价。
目的:评价一种新的矢状高度拟合算法,用于欧几里得角膜塑形镜试验中对准曲线半径的估计。方法:选取中国近视儿童为研究对象,随机分为两组。采用新的拟合算法计算了其中一组的交流半径。另一组的交流半径由验光师使用平K读数和偏心值决定。记录每位患者的晶状体试验次数,并通过Pearson相关性和Bland-Altman图检验首次试验晶状体与最终订购晶状体之间的交流半径的一致性。结果:入选青少年患者103只眼,其中男生57只,女生46只。新算法与传统方法的试验次数分别为1.2±0.4次和1.4±0.5次,两种方法的试验次数差异有统计学意义(t=2.404, P=0.018)。新算法与传统方法的第一次试镜与待生产透镜的AC值之差分别为0.000±0.020 mm和0.003±0.028 mm。两种方法比较差异无统计学意义(t=0.748, P=0.456)。结论:新型矢状面高度模拟软件能准确计算出适合我国患者的角膜塑形镜的AC值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书