Dual-Layer Spectral Detector CT in Comparison with FDG-PET/CT for the Assessment of Lymphoma Activity.

IF 1.7
Kim Gehling, Theresa Mokry, Thuy Duong Do, Frederik Lars Giesel, Sascha Dietrich, Uwe Haberkorn, Hans-Ulrich Kauczor, Tim Frederik Weber
{"title":"Dual-Layer Spectral Detector CT in Comparison with FDG-PET/CT for the Assessment of Lymphoma Activity.","authors":"Kim Gehling,&nbsp;Theresa Mokry,&nbsp;Thuy Duong Do,&nbsp;Frederik Lars Giesel,&nbsp;Sascha Dietrich,&nbsp;Uwe Haberkorn,&nbsp;Hans-Ulrich Kauczor,&nbsp;Tim Frederik Weber","doi":"10.1055/a-1735-3477","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>In patients with malignant lymphoma, disease activity is recommended to be assessed by FDG-PET/CT and the Deauville five-point scale (5-PS). The purpose of this study was to explore the potential of iodine concentration measured in contrast-enhanced dual-layer spectral detector CT (SDCT) as an alternative surrogate parameter for lymphoma disease activity by investigating its correlation with maximum standardized uptake values (SUV<sub>max</sub>) and 5-PS.</p><p><strong>Materials and methods: </strong>25 patients were retrospectively analyzed. Contrast-enhanced SDCT and FDG-PET/CT were performed in the same treatment interval within at most 3 months. CT attenuation values (AV), absolute iodine concentrations (aIC), and normalized iodine concentrations (nIC) of lymphoma lesions were correlated with SUV<sub>max</sub> using Spearman's rank correlation coefficient. The performance of aIC and nIC to detect lymphoma activity (defined as 5-PS > 3) was determined using ROC curves.</p><p><strong>Results: </strong>60 lesions were analyzed, and 31 lesions were considered active. AV, aIC, and nIC all correlated significantly with SUV<sub>max</sub>. The strongest correlation (Spearman ρ = 0.71; p < 0.001) and highest area under the ROC curve (AUROC) for detecting lymphoma activity were observed for nIC normalized to inferior vena cava enhancement (AUROC = 0.866). The latter provided sensitivity, specificity, and diagnostic accuracy of 87 %, 75 %, and 80 %, respectively, at a threshold of 0.20. ROC analysis for AV (AUROC = 0.834) and aIC (AUROC = 0.853) yielded similar results.</p><p><strong>Conclusion: </strong>In malignant lymphomas, there is a significant correlation between metabolic activity as assessed by FDG-PET/CT and iodine concentration as assessed by SDCT. Iodine concentration shows promising diagnostic performance for detecting lymphoma activity and may represent a potential imaging biomarker.</p><p><strong>Key points: </strong>· Iodine concentration correlates significantly with SUVmax in lymphoma patients. · Iodine concentration may represent a potential imaging biomarker for detecting lymphoma activity. · Normalization of iodine concentration improves diagnostic performance of iodine concentration.</p><p><strong>Citation format: </strong>· Gehling K, Mokry T, Do TD et al. Dual-Layer Spectral Detector CT in Comparison with FDG-PET/CT for the Assessment of Lymphoma Activity. Fortschr Röntgenstr 2022; 194: 747 - 754.</p>","PeriodicalId":520772,"journal":{"name":"RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin","volume":" ","pages":"747-754"},"PeriodicalIF":1.7000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-1735-3477","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/2/24 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Purpose: In patients with malignant lymphoma, disease activity is recommended to be assessed by FDG-PET/CT and the Deauville five-point scale (5-PS). The purpose of this study was to explore the potential of iodine concentration measured in contrast-enhanced dual-layer spectral detector CT (SDCT) as an alternative surrogate parameter for lymphoma disease activity by investigating its correlation with maximum standardized uptake values (SUVmax) and 5-PS.

Materials and methods: 25 patients were retrospectively analyzed. Contrast-enhanced SDCT and FDG-PET/CT were performed in the same treatment interval within at most 3 months. CT attenuation values (AV), absolute iodine concentrations (aIC), and normalized iodine concentrations (nIC) of lymphoma lesions were correlated with SUVmax using Spearman's rank correlation coefficient. The performance of aIC and nIC to detect lymphoma activity (defined as 5-PS > 3) was determined using ROC curves.

Results: 60 lesions were analyzed, and 31 lesions were considered active. AV, aIC, and nIC all correlated significantly with SUVmax. The strongest correlation (Spearman ρ = 0.71; p < 0.001) and highest area under the ROC curve (AUROC) for detecting lymphoma activity were observed for nIC normalized to inferior vena cava enhancement (AUROC = 0.866). The latter provided sensitivity, specificity, and diagnostic accuracy of 87 %, 75 %, and 80 %, respectively, at a threshold of 0.20. ROC analysis for AV (AUROC = 0.834) and aIC (AUROC = 0.853) yielded similar results.

Conclusion: In malignant lymphomas, there is a significant correlation between metabolic activity as assessed by FDG-PET/CT and iodine concentration as assessed by SDCT. Iodine concentration shows promising diagnostic performance for detecting lymphoma activity and may represent a potential imaging biomarker.

Key points: · Iodine concentration correlates significantly with SUVmax in lymphoma patients. · Iodine concentration may represent a potential imaging biomarker for detecting lymphoma activity. · Normalization of iodine concentration improves diagnostic performance of iodine concentration.

Citation format: · Gehling K, Mokry T, Do TD et al. Dual-Layer Spectral Detector CT in Comparison with FDG-PET/CT for the Assessment of Lymphoma Activity. Fortschr Röntgenstr 2022; 194: 747 - 754.

双层光谱检测CT与FDG-PET/CT评估淋巴瘤活动性的比较。
目的:在恶性淋巴瘤患者中,推荐使用FDG-PET/CT和Deauville五点评分(5-PS)评估疾病活动性。本研究的目的是通过研究对比增强双层光谱检测器CT (SDCT)测量的碘浓度与最大标准化摄取值(SUVmax)和5-PS的相关性,探讨其作为淋巴瘤疾病活动性替代参数的潜力。材料和方法:对25例患者进行回顾性分析。对比增强SDCT和FDG-PET/CT在最多3个月内的同一治疗间隔内进行。CT衰减值(AV)、绝对碘浓度(aIC)、归一化碘浓度(nIC)与SUVmax的相关性采用Spearman秩相关系数。采用ROC曲线确定aIC和nIC检测淋巴瘤活动性(定义为5-PS > 3)的性能。结果:共分析病变60个,其中31个为活动性病变。AV、aIC、nIC与SUVmax均有显著相关。相关性最强(Spearman ρ = 0.71;结论:在恶性淋巴瘤中,FDG-PET/CT评估的代谢活性与SDCT评估的碘浓度之间存在显著相关性。碘浓度在检测淋巴瘤活动性方面显示出有希望的诊断性能,并可能代表一种潜在的成像生物标志物。·碘浓度与淋巴瘤患者SUVmax显著相关。·碘浓度可能是检测淋巴瘤活动性的潜在成像生物标志物。·碘浓度正常化可提高碘浓度的诊断效能。引用格式:·Gehling K, Mokry T, Do TD等。双层光谱检测CT与FDG-PET/CT评估淋巴瘤活动性的比较。Fortschr Röntgenstr 2022;194: 747 - 754。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书