{"title":"Improvement in Ionization Efficiency Using Metal Oxide Nanoparticles in Laser Desorption/Ionization Mass Spectrometry of a Cancer Drug.","authors":"Hiroki Kannen, Yuto Miyoshi, Hisanao Hazama, Kunio Awazu","doi":"10.5702/massspectrometry.A0099","DOIUrl":null,"url":null,"abstract":"<p><p>Mass spectrometry imaging (MSI) without labeling has the potential for faster screening in drug development. Matrix-assisted laser desorption/ionization (MALDI) is typically used, but it has a large matrix size and uneven drug distribution. Surface-assisted laser desorption/ionization (SALDI) using nanoparticles (NPs) may overcome these issues. Here, the influence of NPs, solvent ratio, and order of dropping of NPs on SALDI-MSI of protoporphyrin IX (PpIX), a cancer drug, are reported. A solution of PpIX in a 50% aqueous solution of 50% acetonitrile at a concentration of 10 μM was used. The NPs include ZnO, Fe<sub>3</sub>O<sub>4</sub>, and four types of TiO<sub>2</sub>. The NPs were fabricated by dissolving them on an aqueous 90% acetonitrile solution. Mass spectra were obtained with a time-of-flight mass spectrometer using a Nd:YAG laser at a 355-nm wavelength. The signal intensity using TiO<sub>2</sub> at a 0.5 mg/mL concentration in 50% acetonitrile was increased by 1.6-fold compared to that without TiO<sub>2</sub>. Changing the solvent to 90% acetonitrile gave a uniform TiO<sub>2</sub> distribution and a 9-fold increase in the signal intensity for PpIX. Among the four types of TiO<sub>2</sub> with different particle sizes and crystal structures, TiO<sub>2</sub> with a smaller particle size and a rutile crystal structure produced the highest signal intensity. Forming a layer on top of the PpIX also resulted in an increased signal intensity. Hence, SALDI using TiO<sub>2</sub> provides effective ionization of the drug. In the future, we plan to investigate a spray method for the ionization of PpIX using TiO<sub>2</sub> for the MSI of various drugs.</p>","PeriodicalId":18243,"journal":{"name":"Mass spectrometry","volume":"10 1","pages":"A0099"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8697360/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mass spectrometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5702/massspectrometry.A0099","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/12/23 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Physics and Astronomy","Score":null,"Total":0}
引用次数: 0
Abstract
Mass spectrometry imaging (MSI) without labeling has the potential for faster screening in drug development. Matrix-assisted laser desorption/ionization (MALDI) is typically used, but it has a large matrix size and uneven drug distribution. Surface-assisted laser desorption/ionization (SALDI) using nanoparticles (NPs) may overcome these issues. Here, the influence of NPs, solvent ratio, and order of dropping of NPs on SALDI-MSI of protoporphyrin IX (PpIX), a cancer drug, are reported. A solution of PpIX in a 50% aqueous solution of 50% acetonitrile at a concentration of 10 μM was used. The NPs include ZnO, Fe3O4, and four types of TiO2. The NPs were fabricated by dissolving them on an aqueous 90% acetonitrile solution. Mass spectra were obtained with a time-of-flight mass spectrometer using a Nd:YAG laser at a 355-nm wavelength. The signal intensity using TiO2 at a 0.5 mg/mL concentration in 50% acetonitrile was increased by 1.6-fold compared to that without TiO2. Changing the solvent to 90% acetonitrile gave a uniform TiO2 distribution and a 9-fold increase in the signal intensity for PpIX. Among the four types of TiO2 with different particle sizes and crystal structures, TiO2 with a smaller particle size and a rutile crystal structure produced the highest signal intensity. Forming a layer on top of the PpIX also resulted in an increased signal intensity. Hence, SALDI using TiO2 provides effective ionization of the drug. In the future, we plan to investigate a spray method for the ionization of PpIX using TiO2 for the MSI of various drugs.