[Evaluation of Screening Performance and Detection Time of Carbapenemase-Producing Enterobacterales Using RAISUS S4 in a Antimicrobial Sensitivity Test].

Yumiko Funashima, Hiroki Hanaiwa, Taeko Narita, Zenzo Nagasawa
{"title":"[Evaluation of Screening Performance and Detection Time of Carbapenemase-Producing <i>Enterobacterales</i> Using RAISUS S4 in a Antimicrobial Sensitivity Test].","authors":"Yumiko Funashima,&nbsp;Hiroki Hanaiwa,&nbsp;Taeko Narita,&nbsp;Zenzo Nagasawa","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Rapid detection of carbapenemase-producing <i>Enterobacterales</i> (CPE) is important in infection control, since it transmits plasmids carrying resistance genes. Here, we evaluated the rapid detection of CPE using the fully automated antimicrobial susceptability testing system \"RAISUS S4\". Sixty-two CPE strains including carbapenem-resistant <i>Enterobacterales</i> and 100 carbapenemase-non-producing <i>Enterobacterales</i> strains were used. RAISUS S4 was performed using both 18 hr and rapid methods. The sensitivity of CPE detection and decision time were evaluated using Meropenem results. The results showed that the sensitivity for CPE detection was 100% for both methods, with specificity of 97% for the 18 hr method and 95% for the rapid method. The mean CPE detection time for the 18 hr method was 7.2 hrs and 8.8 hrs for the rapid method. The mean MIC determination time of the 18 hr method for all 162 strains was 17.2 hrs and 8.8 hrs for the rapid method. In addition, we analyzed the absorbance values of the 18 hr method. Checking the growth curve at a drug concentration of 0.125 µg/ml and determining it to be positive when its absorbance reached 0.8 Abs, CPE could be detected in an average of 5.8 hrs with in sensitivity of 100% and specificity of 92%. The 18 hr method of RAISUS S4 allowed rapid detection of CPE, and the rapid method allowed earlier MIC determination, including sensitive isolates. These results suggest that RAISUS S4 can detect CPE rapidly without missing CPE by routine test even in Japan where the frequency of CPE isolation is low.</p>","PeriodicalId":74740,"journal":{"name":"Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM : Journal of the Association for Rapid Method and Automation in Microbiology","volume":"31 1","pages":"7-13"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM : Journal of the Association for Rapid Method and Automation in Microbiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Rapid detection of carbapenemase-producing Enterobacterales (CPE) is important in infection control, since it transmits plasmids carrying resistance genes. Here, we evaluated the rapid detection of CPE using the fully automated antimicrobial susceptability testing system "RAISUS S4". Sixty-two CPE strains including carbapenem-resistant Enterobacterales and 100 carbapenemase-non-producing Enterobacterales strains were used. RAISUS S4 was performed using both 18 hr and rapid methods. The sensitivity of CPE detection and decision time were evaluated using Meropenem results. The results showed that the sensitivity for CPE detection was 100% for both methods, with specificity of 97% for the 18 hr method and 95% for the rapid method. The mean CPE detection time for the 18 hr method was 7.2 hrs and 8.8 hrs for the rapid method. The mean MIC determination time of the 18 hr method for all 162 strains was 17.2 hrs and 8.8 hrs for the rapid method. In addition, we analyzed the absorbance values of the 18 hr method. Checking the growth curve at a drug concentration of 0.125 µg/ml and determining it to be positive when its absorbance reached 0.8 Abs, CPE could be detected in an average of 5.8 hrs with in sensitivity of 100% and specificity of 92%. The 18 hr method of RAISUS S4 allowed rapid detection of CPE, and the rapid method allowed earlier MIC determination, including sensitive isolates. These results suggest that RAISUS S4 can detect CPE rapidly without missing CPE by routine test even in Japan where the frequency of CPE isolation is low.

[RAISUS S4抗菌敏感性试验对产碳青霉烯酶肠杆菌筛选性能及检测时间的评价]。
产碳青霉烯酶肠杆菌(CPE)的快速检测对感染控制具有重要意义,因为它传播携带抗性基因的质粒。在这里,我们评估了全自动抗菌药物敏感性试验系统“RAISUS S4”对CPE的快速检测。采用62株CPE菌株,包括耐碳青霉烯类肠杆菌和100株不产碳青霉烯类肠杆菌。RAISUS S4采用18小时和快速两种方法。用美罗培南的结果评价CPE检测的灵敏度和决策时间。结果表明,两种方法检测CPE的灵敏度均为100%,其中18小时法特异性为97%,快速法特异性为95%。18小时法检测CPE的平均时间为7.2小时,快速法为8.8小时。18小时法测定162株的平均MIC时间为17.2小时,快速法测定的平均MIC时间为8.8小时。此外,我们还分析了18hr法的吸光度值。在药物浓度为0.125µg/ml时检查生长曲线,吸光度达到0.8 Abs时判定为阳性,平均5.8 h即可检出CPE,灵敏度为100%,特异性为92%。RAISUS S4的18小时方法可以快速检测CPE,快速方法可以早期检测MIC,包括敏感分离株。这些结果表明,即使在CPE分离率较低的日本,RAISUS S4也能快速检测出CPE而不会遗漏CPE。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信