Martina Schmidbauer, Lars Grenacher, Markus S Juchems, Erik Memmel, Thomas Lauenstein, Andreas G Schreyer, Niklas Verloh, Claus Becker, Thomas J Vogl, Johannes Wessling, Frank K Wacker, Kristina Imeen Ringe
{"title":"Impact of the COVID 19 Pandemic on Radiological Imaging in Germany.","authors":"Martina Schmidbauer, Lars Grenacher, Markus S Juchems, Erik Memmel, Thomas Lauenstein, Andreas G Schreyer, Niklas Verloh, Claus Becker, Thomas J Vogl, Johannes Wessling, Frank K Wacker, Kristina Imeen Ringe","doi":"10.1055/a-1710-3767","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To analyze the impact of the COVID-19 pandemic in 2020 on the radiological imaging volume in Germany.</p><p><strong>Materials und methods: </strong>In this retrospective multicenter study, we analyzed CT and MRI examinations of 7 radiology institutes across Germany from January to December 2020. The imaging volume was compared to 2019 (Wilcoxon-Mann-Whitney test). Modality, patient service locations, and examined body parts were assessed in consideration of time periods of the pandemic. In addition, correlation with the incidence of SARS-CoV-2 cases and associated death was performed (Spearman-test).</p><p><strong>Results: </strong>In total, in 2020, imaging volume declined by 4 % (n = 8314) compared with 2019 (p < 0.05). The hard lockdown during the first pandemic wave (calendar week 12-16, March 22 - April 19) revealed the highest decrease with 29 % (n = 894, p < 0.01), with the greatest decrease in CT (36 % vs. MRI 26 %), outpatients (38 %, p < 0.01), and imaging of the spine and extremities (51-72 %, < 0.05 - p < 0.01). Examinations referred from the emergency department (-13 %, p < 0.05) and CT of the chest (-16 %, p < 0.05) were least affected. With the end of the first wave, gradual normalization of the imaging volume was observed and persisted until the end of the observation period. A reduction of imaging volume negatively correlated with the incidence of SARS-CoV-2-positive cases and associated deaths (r = 0.28 and 0.49, p < 0.05 and p < 0.001).</p><p><strong>Conclusion: </strong>The COVID-19 pandemic was associated with a significant temporary decline in imaging volume. After the first lockdown period, a quick recovery was observed with radiologic imaging examinations steadily approaching prior-year figures.</p><p><strong>Key points: </strong>· This study assesses the impact of dynamic pandemic activity on radiological imaging in a multicenter analysis in Germany.. · The COVID-19 pandemic was associated with a temporary decline in CT and MRI scans.. · Relaxation of restrictions was associated with fast normalization of imaging volumes to prior-year levels, which persisted until the end of the year.. · Significant catch-up effects were not observed..</p><p><strong>Citation format: </strong>· Schmidbauer M, Grenacher L, Juchems MS et al. Impact of the COVID 19 Pandemic on Radiological Imaging in Germany. Fortschr Röntgenstr 2022; 194: 625 - 633.</p>","PeriodicalId":520772,"journal":{"name":"RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin","volume":" ","pages":"625-633"},"PeriodicalIF":1.7000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-1710-3767","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/12/28 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
Purpose: To analyze the impact of the COVID-19 pandemic in 2020 on the radiological imaging volume in Germany.
Materials und methods: In this retrospective multicenter study, we analyzed CT and MRI examinations of 7 radiology institutes across Germany from January to December 2020. The imaging volume was compared to 2019 (Wilcoxon-Mann-Whitney test). Modality, patient service locations, and examined body parts were assessed in consideration of time periods of the pandemic. In addition, correlation with the incidence of SARS-CoV-2 cases and associated death was performed (Spearman-test).
Results: In total, in 2020, imaging volume declined by 4 % (n = 8314) compared with 2019 (p < 0.05). The hard lockdown during the first pandemic wave (calendar week 12-16, March 22 - April 19) revealed the highest decrease with 29 % (n = 894, p < 0.01), with the greatest decrease in CT (36 % vs. MRI 26 %), outpatients (38 %, p < 0.01), and imaging of the spine and extremities (51-72 %, < 0.05 - p < 0.01). Examinations referred from the emergency department (-13 %, p < 0.05) and CT of the chest (-16 %, p < 0.05) were least affected. With the end of the first wave, gradual normalization of the imaging volume was observed and persisted until the end of the observation period. A reduction of imaging volume negatively correlated with the incidence of SARS-CoV-2-positive cases and associated deaths (r = 0.28 and 0.49, p < 0.05 and p < 0.001).
Conclusion: The COVID-19 pandemic was associated with a significant temporary decline in imaging volume. After the first lockdown period, a quick recovery was observed with radiologic imaging examinations steadily approaching prior-year figures.
Key points: · This study assesses the impact of dynamic pandemic activity on radiological imaging in a multicenter analysis in Germany.. · The COVID-19 pandemic was associated with a temporary decline in CT and MRI scans.. · Relaxation of restrictions was associated with fast normalization of imaging volumes to prior-year levels, which persisted until the end of the year.. · Significant catch-up effects were not observed..
Citation format: · Schmidbauer M, Grenacher L, Juchems MS et al. Impact of the COVID 19 Pandemic on Radiological Imaging in Germany. Fortschr Röntgenstr 2022; 194: 625 - 633.