Computed Tomography-Derived Three-Dimensional Printed Models versus Two-Dimensional Transesophageal Echocardiography for Left Atrial Appendage Occlusion Device Planning: A Systematic Review and Meta-Analysis.

Q3 Medicine
Journal of atrial fibrillation Pub Date : 2020-12-31 eCollection Date: 2020-12-01 DOI:10.4022/jafib.2433
Garly Saint Croix, Syed Imran Zaidi, Viky S Loescher, Christos G Mihos
{"title":"Computed Tomography-Derived Three-Dimensional Printed Models versus Two-Dimensional Transesophageal Echocardiography for Left Atrial Appendage Occlusion Device Planning: A Systematic Review and Meta-Analysis.","authors":"Garly Saint Croix, Syed Imran Zaidi, Viky S Loescher, Christos G Mihos","doi":"10.4022/jafib.2433","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This systematic review and meta-analysis compared computed tomography (CT)-derived three-dimensional (3D) modeling versus two-dimensional transesophageal echocardiography (TEE) for left atrial appendage occluder (LAAO) device planning.</p><p><strong>Background: </strong>LAAO device planning is commonly performed with TEE. However, procedures often require multiple devices and deployments due to inaccurate sizing from TEE. The use of CT three-dimensional (3D) models for LAAO device planning may improve accuracy.</p><p><strong>Methods: </strong>Four clinical studies that reported procedural and clinical outcomes for CT-derived 3D modeling versus TEE for LAAO device planning were identified. End points were accurate device sizing, procedure failure, number of devices used per procedure, fluoroscopy time, and post-procedure leak. Risk ratio (RR) and mean difference (MD) with a 95% confidence interval (CI) were calculated by the Mantel-Haenszel and inverse variance methods.</p><p><strong>Results: </strong>A total of 166 participants were included. When compared with conventional imaging, the use of 3D printed models was associated with less fluoroscopy time (MD -6.98 minutes, 95% CI -12.68 to -1.28, p=0.02) and lower risk of occluder device peri-prosthetic leak (RR 0.23, 95% CI 0.07-0.73, p=0.01) for LAAO. There were signals towards lower number of devices per procedure (MD -0.56 devices, 95% CI -1.16-0.05, p=0.07) and less total procedure time (MD -13.50 minutes, 95% CI -28.14-1.14, p=0.07) with printed modeling for LAAO. There was no difference between modalities in rates of procedure failure.</p><p><strong>Conclusions: </strong>CT-derived 3D printed models for LAAO device planning may offer the advantages of lower LAAO device peri-prosthetic leak and less fluoroscopy time when compared with conventional TEE guidance.</p>","PeriodicalId":15072,"journal":{"name":"Journal of atrial fibrillation","volume":"13 4","pages":"2433"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8691300/pdf/jafib-13-02433.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of atrial fibrillation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4022/jafib.2433","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/12/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: This systematic review and meta-analysis compared computed tomography (CT)-derived three-dimensional (3D) modeling versus two-dimensional transesophageal echocardiography (TEE) for left atrial appendage occluder (LAAO) device planning.

Background: LAAO device planning is commonly performed with TEE. However, procedures often require multiple devices and deployments due to inaccurate sizing from TEE. The use of CT three-dimensional (3D) models for LAAO device planning may improve accuracy.

Methods: Four clinical studies that reported procedural and clinical outcomes for CT-derived 3D modeling versus TEE for LAAO device planning were identified. End points were accurate device sizing, procedure failure, number of devices used per procedure, fluoroscopy time, and post-procedure leak. Risk ratio (RR) and mean difference (MD) with a 95% confidence interval (CI) were calculated by the Mantel-Haenszel and inverse variance methods.

Results: A total of 166 participants were included. When compared with conventional imaging, the use of 3D printed models was associated with less fluoroscopy time (MD -6.98 minutes, 95% CI -12.68 to -1.28, p=0.02) and lower risk of occluder device peri-prosthetic leak (RR 0.23, 95% CI 0.07-0.73, p=0.01) for LAAO. There were signals towards lower number of devices per procedure (MD -0.56 devices, 95% CI -1.16-0.05, p=0.07) and less total procedure time (MD -13.50 minutes, 95% CI -28.14-1.14, p=0.07) with printed modeling for LAAO. There was no difference between modalities in rates of procedure failure.

Conclusions: CT-derived 3D printed models for LAAO device planning may offer the advantages of lower LAAO device peri-prosthetic leak and less fluoroscopy time when compared with conventional TEE guidance.

计算机断层扫描生成的三维打印模型与二维经食道超声心动图在左房阑尾闭塞装置规划中的对比:系统回顾与元分析》。
目的:本系统综述和荟萃分析比较了计算机断层扫描(CT)生成的三维(3D)建模与二维经食道超声心动图(TEE)在左心房阑尾封堵器(LAAO)装置规划中的应用:背景:通常使用 TEE 进行 LAAO 装置规划。背景:通常使用 TEE 进行 LAAO 装置规划。然而,由于 TEE 的尺寸不准确,手术通常需要多个装置和部署。使用 CT 三维(3D)模型进行 LAAO 装置规划可提高准确性:方法:确定了四项临床研究,这些研究报告了 CT 导出三维模型与 TEE 对 LAAO 装置规划的程序和临床结果。研究终点为准确的装置尺寸、手术失败、每次手术使用的装置数量、透视时间和手术后渗漏。采用曼特尔-海恩斯泽尔法和逆方差法计算风险比(RR)和平均差(MD)及95%置信区间(CI):结果:共纳入 166 名参与者。与传统成像相比,使用3D打印模型可减少透视时间(MD为-6.98分钟,95% CI为-12.68至-1.28,P=0.02),降低LAAO闭塞器假体周围泄漏的风险(RR为0.23,95% CI为0.07至0.73,P=0.01)。有迹象表明,LAAO 采用印刷建模后,每次手术的装置数量减少(MD -0.56 个装置,95% CI -1.16-0.05 ,P=0.07),手术总时间缩短(MD -13.50 分钟,95% CI -28.14-1.14 ,P=0.07)。不同模式的手术失败率没有差异:结论:与传统的 TEE 引导相比,用于 LAAO 装置规划的 CT 导出 3D 打印模型具有 LAAO 装置假体周围渗漏少、透视时间短的优点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of atrial fibrillation
Journal of atrial fibrillation Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信