Pilot study of the diagnostic utility of 89 Zr-df-IAB2M and 68 Ga-PSMA-11 PET imaging and multiparametric MRI in localized prostate cancer.

The Prostate Pub Date : 2022-03-01 Epub Date: 2022-01-05 DOI:10.1002/pros.24294
Panagiotis J Vlachostergios, Muhammad J Niaz, Charlene Thomas, Paul J Christos, Joseph R Osborne, Daniel J A Margolis, Francesca Khani, Neil H Bander, Douglas S Scherr, Scott T Tagawa
{"title":"Pilot study of the diagnostic utility of <sup>89</sup> Zr-df-IAB2M and <sup>68</sup> Ga-PSMA-11 PET imaging and multiparametric MRI in localized prostate cancer.","authors":"Panagiotis J Vlachostergios,&nbsp;Muhammad J Niaz,&nbsp;Charlene Thomas,&nbsp;Paul J Christos,&nbsp;Joseph R Osborne,&nbsp;Daniel J A Margolis,&nbsp;Francesca Khani,&nbsp;Neil H Bander,&nbsp;Douglas S Scherr,&nbsp;Scott T Tagawa","doi":"10.1002/pros.24294","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Accurate diagnosis of localized prostate cancer (PCa) is limited by inadequacy of multiparametric (mp) MRI to fully identify and differentiate localized malignant tissue from benign pathologies. Prostate-specific membrane antigen (PSMA) represents an excellent target for molecular imaging. IAB2M, an 85-kD minibody derived from a de-immunized monoclonal antibody directed at the extracellular domain of human PSMA (huJ591), and PSMA-11, a small molecule ligand have been previously tested as probes for visualization of recurrent/metastatic PCa with PET/CT. This pilot, non-randomized trial studied their diagnostic utility in patients (pts) with localized PCa.</p><p><strong>Methods: </strong>Pts planned for radical prostatectomy (RP) were enrolled and underwent mpMRI and PET/CT imaging with <sup>89</sup> Zr-df-IAB2M and/or <sup>68</sup> Ga-PSMA-PET/CT. Image results were read by a radiologist blinded to clinical information and pathology results, mapped and compared to corresponding histopathology findings from all lesions, both clinically significant and nonsignificant. The detection rates of all three imaging modalities were measured and correlated.</p><p><strong>Results: </strong>20 pts with median age of 64.5 (46-79) years and PSA level of 7.5 (1.6-36.56) ng/ml were enrolled. 19 pts underwent RP and were imaged pre-operatively with <sup>89</sup> Zr-Df-IAB2M PET/CT and mpMRI. Nine of those were imaged using <sup>68</sup> Ga-PSMA-11 as well. Out of 48 intraprostatic lesions verified on surgical pathology, IAB2M PET/CT was able to detect 36 (75%). A similar proportion of pathologically confirmed, clinically significant lesions (22/29, 76%) was detected. IAB2M PET/CT was also able to identify 14/19 (74%) extraprostatic lesions. The performance of mpMRI was inferior, with 24/48 detectable lesions (50%) and 18/29 clinically significant intraprostatic lesions (62%). Compared to the current standard (mpMRI), IAB2M PET/CT had a sensitivity of 88%, specificity 38%, positive predictive value 58%, and accuracy 63%. In 9 pts who underwent Ga-PSMA-11 as well, the latter yielded a detection rate of 70% (14/20), which was also seen in clinically significant lesions (10/14, 71%). Ga-PSMA-11 PET/CT also detected 4/6 (67%) extraprostatic lesions.</p><p><strong>Conclusions: </strong>In this pilot study, the performance of <sup>89</sup> Zr-df-IAB2M was superior to mpMRI and similar to <sup>68</sup> Ga-PSMA-11 PET/CT. The higher detection rate of PSMA-PET supports its use as a diagnostic tool with consequent management change implications in men with localized PCa.</p>","PeriodicalId":501684,"journal":{"name":"The Prostate","volume":" ","pages":"483-492"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Prostate","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/pros.24294","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/5 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

Background: Accurate diagnosis of localized prostate cancer (PCa) is limited by inadequacy of multiparametric (mp) MRI to fully identify and differentiate localized malignant tissue from benign pathologies. Prostate-specific membrane antigen (PSMA) represents an excellent target for molecular imaging. IAB2M, an 85-kD minibody derived from a de-immunized monoclonal antibody directed at the extracellular domain of human PSMA (huJ591), and PSMA-11, a small molecule ligand have been previously tested as probes for visualization of recurrent/metastatic PCa with PET/CT. This pilot, non-randomized trial studied their diagnostic utility in patients (pts) with localized PCa.

Methods: Pts planned for radical prostatectomy (RP) were enrolled and underwent mpMRI and PET/CT imaging with 89 Zr-df-IAB2M and/or 68 Ga-PSMA-PET/CT. Image results were read by a radiologist blinded to clinical information and pathology results, mapped and compared to corresponding histopathology findings from all lesions, both clinically significant and nonsignificant. The detection rates of all three imaging modalities were measured and correlated.

Results: 20 pts with median age of 64.5 (46-79) years and PSA level of 7.5 (1.6-36.56) ng/ml were enrolled. 19 pts underwent RP and were imaged pre-operatively with 89 Zr-Df-IAB2M PET/CT and mpMRI. Nine of those were imaged using 68 Ga-PSMA-11 as well. Out of 48 intraprostatic lesions verified on surgical pathology, IAB2M PET/CT was able to detect 36 (75%). A similar proportion of pathologically confirmed, clinically significant lesions (22/29, 76%) was detected. IAB2M PET/CT was also able to identify 14/19 (74%) extraprostatic lesions. The performance of mpMRI was inferior, with 24/48 detectable lesions (50%) and 18/29 clinically significant intraprostatic lesions (62%). Compared to the current standard (mpMRI), IAB2M PET/CT had a sensitivity of 88%, specificity 38%, positive predictive value 58%, and accuracy 63%. In 9 pts who underwent Ga-PSMA-11 as well, the latter yielded a detection rate of 70% (14/20), which was also seen in clinically significant lesions (10/14, 71%). Ga-PSMA-11 PET/CT also detected 4/6 (67%) extraprostatic lesions.

Conclusions: In this pilot study, the performance of 89 Zr-df-IAB2M was superior to mpMRI and similar to 68 Ga-PSMA-11 PET/CT. The higher detection rate of PSMA-PET supports its use as a diagnostic tool with consequent management change implications in men with localized PCa.

89 Zr-df-IAB2M和68 Ga-PSMA-11 PET成像和多参数MRI诊断局限性前列腺癌的初步研究
背景:多参数磁共振成像(mp)不足以充分识别和区分局部恶性组织与良性病理,限制了局部前列腺癌(PCa)的准确诊断。前列腺特异性膜抗原(PSMA)是分子成像的一个很好的靶点。IAB2M是一种85-kD的小体,来自于一种针对人PSMA细胞外结构域的去免疫单克隆抗体(huJ591), PSMA-11是一种小分子配体,此前已被用作PET/CT显示复发/转移性PCa的探针。这项非随机试验研究了它们在局限性前列腺癌患者中的诊断效用。方法:纳入计划行根治性前列腺切除术(RP)的患者,使用89 Zr-df-IAB2M和/或68 Ga-PSMA-PET/CT进行mpMRI和PET/CT成像。图像结果由不了解临床信息和病理结果的放射科医生读取,绘制并与所有病变的相应组织病理学结果进行比较,包括临床显著和不显著的病变。测量所有三种成像方式的检出率并进行相关性分析。结果:纳入20例患者,中位年龄为64.5(46-79)岁,PSA水平为7.5 (1.6-36.56)ng/ml。19例患者接受RP,术前进行89 Zr-Df-IAB2M PET/CT和mpMRI成像。其中9例也使用68ga - psma -11成像。在手术病理证实的48例前列腺内病变中,IAB2M PET/CT能够检测到36例(75%)。病理证实的临床显著病变比例相似(22/ 29,76 %)。IAB2M PET/CT也能识别14/19(74%)前列腺外病变。mpMRI表现较差,有24/48可检出病变(50%),18/29有临床意义的前列腺内病变(62%)。与现行标准(mpMRI)相比,IAB2M PET/CT的敏感性为88%,特异性为38%,阳性预测值为58%,准确性为63%。在接受Ga-PSMA-11治疗的9例患者中,后者的检出率为70%(14/20),在临床显著病变中也有发现(10/14,71%)。Ga-PSMA-11 PET/CT检出4/6(67%)前列腺外病变。结论:在本初步研究中,89 Zr-df-IAB2M的表现优于mpMRI,与68 Ga-PSMA-11 PET/CT相似。PSMA-PET较高的检出率支持其作为诊断工具的使用,从而对局限性前列腺癌患者的管理改变具有重要意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书