A novel synergistic device for joint inflammation - efficacy on ankle sprain cases.

Q3 Engineering
Mayank Shukla, S S Agrawal
{"title":"A novel synergistic device for joint inflammation - efficacy on ankle sprain cases.","authors":"Mayank Shukla,&nbsp;S S Agrawal","doi":"10.1080/03091902.2022.2039312","DOIUrl":null,"url":null,"abstract":"<p><p>Joint inflammation results from soft-tissue injuries and cartilage damage. PRICE is the standard treatment approach for acute soft tissue injuries like ankle sprain. Electrical stimulation, application of orthotic braces, etc. is also effective for this. In a synergistic device all these components are combined and applied simultaneously. This device was developed for joint inflammation and tested for grade I & II acute ankle joint sprain. To test a synergistic - semirigid device, combining PRICE & electrical stimulation for acute ankle sprains of grades I & II for pain, range of motion and swelling is a case series was the objective. Device was developed using novel concept of synergistic applications of PRICE with electrical stimulation. The joint contour of ankle and specific biomechanical bony surface landmarks were considered. Ethical approval was taken from NTCC committee, AIPT. Recordings were taken from eight patients of acute ankle sprain with - in two days of injury, after getting ethical approval. Elevation to the ankle was provided by keeping the part over the pillow and data was recorded with the help of: 1.VAS scale for pain; 2. Measuring tape; 3. Goniometry. <i>t</i>-test was used to find out the significant difference pre and post the application of device. There was a significant reduction in pain (<i>p</i> = 0.006), edema (<i>p</i> = 0.011), dorsi-flexion (<i>p</i> = 0.015), and plantar flexion (<i>p</i> =0.008). The synegistic device has been effective for acute ankle inflammation - grade I & II ankle sprains in 5 sessions; sufficient for the return of function.</p>","PeriodicalId":39637,"journal":{"name":"Journal of Medical Engineering and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/03091902.2022.2039312","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/2/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

Abstract

Joint inflammation results from soft-tissue injuries and cartilage damage. PRICE is the standard treatment approach for acute soft tissue injuries like ankle sprain. Electrical stimulation, application of orthotic braces, etc. is also effective for this. In a synergistic device all these components are combined and applied simultaneously. This device was developed for joint inflammation and tested for grade I & II acute ankle joint sprain. To test a synergistic - semirigid device, combining PRICE & electrical stimulation for acute ankle sprains of grades I & II for pain, range of motion and swelling is a case series was the objective. Device was developed using novel concept of synergistic applications of PRICE with electrical stimulation. The joint contour of ankle and specific biomechanical bony surface landmarks were considered. Ethical approval was taken from NTCC committee, AIPT. Recordings were taken from eight patients of acute ankle sprain with - in two days of injury, after getting ethical approval. Elevation to the ankle was provided by keeping the part over the pillow and data was recorded with the help of: 1.VAS scale for pain; 2. Measuring tape; 3. Goniometry. t-test was used to find out the significant difference pre and post the application of device. There was a significant reduction in pain (p = 0.006), edema (p = 0.011), dorsi-flexion (p = 0.015), and plantar flexion (p =0.008). The synegistic device has been effective for acute ankle inflammation - grade I & II ankle sprains in 5 sessions; sufficient for the return of function.

一种新型关节炎症协同治疗装置——对踝关节扭伤的疗效。
关节炎症是由软组织损伤和软骨损伤引起的。PRICE是治疗踝关节扭伤等急性软组织损伤的标准方法。电刺激、矫形牙套等也是有效的。在一个协同装置中,所有这些组件被组合并同时应用。该装置是为关节炎症而开发的,并对I级和II级急性踝关节扭伤进行了测试。为了测试一种协同-半刚性装置,结合PRICE和电刺激治疗I级和II级急性踝关节扭伤的疼痛,活动范围和肿胀是一个病例系列。该装置是利用PRICE与电刺激协同应用的新概念开发的。考虑了踝关节的关节轮廓和特定的生物力学骨表面标志。伦理批准由NTCC委员会,AIPT。在获得伦理批准后,对8名急性踝关节扭伤患者进行了记录,并在两天内受伤。将受试者置于枕头上方,以抬高至踝关节,并通过以下方法记录数据:1。疼痛VAS评分;2. 卷尺;3.测角术。采用t检验,比较器械使用前后的差异。疼痛(p = 0.006)、水肿(p = 0.011)、背屈(p = 0.015)和足底屈(p =0.008)均显著减轻。该器械对急性踝关节炎症I、II级踝关节扭伤有5次疗效;足以返回函数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Medical Engineering and Technology
Journal of Medical Engineering and Technology Engineering-Biomedical Engineering
CiteScore
4.60
自引率
0.00%
发文量
77
期刊介绍: The Journal of Medical Engineering & Technology is an international, independent, multidisciplinary, bimonthly journal promoting an understanding of the physiological processes underlying disease processes and the appropriate application of technology. Features include authoritative review papers, the reporting of original research, and evaluation reports on new and existing techniques and devices. Each issue of the journal contains a comprehensive information service which provides news relevant to the world of medical technology, details of new products, book reviews, and selected contents of related journals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信