Navigation and non-navigation CT scan of the sinuses: comparison of the effective doses of radiation in children and adults.

IF 2.2
Noémie Villemure-Poliquin, Mario Chrétien, Jacques E Leclerc
{"title":"Navigation and non-navigation CT scan of the sinuses: comparison of the effective doses of radiation in children and adults.","authors":"Noémie Villemure-Poliquin, Mario Chrétien, Jacques E Leclerc","doi":"10.1186/s40463-021-00541-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The advent of 3D navigation imaging has opened new borders to the endoscopic surgical approaches of naso-sinusal inflammatory and neoplastic disease. This technology has gained in popularity among otolaryngologists for endoscopic sinus and skull base surgeries in both adults and children. However, the increased tissue radiation required for data acquisition associated with 3D navigation protocols CT scans is a source of concern because of its potential health hazards. We aimed to compare the effective doses of radiation between 3D navigation protocols and standard protocols for sinus computed tomography (CT) scans for both the adult and pediatric population.</p><p><strong>Methods: </strong>We performed a retrospective cohort study through electronic chart review of patients undergoing sinus CT scans (standard and 3D navigation protocols) from May 2019 to December 2019 using a Siemens Drive (VA62A) CT scanner. The effective dose of radiation was calculated in mSv for all exams. Average irradiation doses were compared using a Student's T-Test or a Kruskall-Wallis test when appropriate.</p><p><strong>Results: </strong>A total of 115 CT scans were selected for analysis, of which 47 were standard protocols and 68 were 3D navigation protocols CT scans. Among these, 31 exams were performed on children and 84 exams on adults. For the total population, mean effective dose in the non-navigation CT scans was 0.37 mSv (SD: 0.16, N = 47) and mean effective dose in the 3D navigation sinus CT group was 2.33 mSv (SD: 0.45, N = 68). The mean difference between the two groups was statistically significant 1.97 mSv (CI 95% - 2.1 to - 1.83; P < 0.0001). There was a sixfold increase in radiation with utilization of 3D navigation protocols. The ratio was identical when the pediatric as well as the adult subset of patients were analyzed.</p><p><strong>Conclusion: </strong>In our center, utilization of 3D navigation sinus CT protocols significantly increases radiation exposure. Otolaryngologists should be aware of this significant increase and should attempt to decrease the radiation exposure of their patients by limiting unnecessary scan orders and by evaluating 3D acquisition protocols locally with radiation physicists.</p><p><strong>Level of evidence: </strong>Level IV.</p>","PeriodicalId":520683,"journal":{"name":"Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale","volume":" ","pages":"66"},"PeriodicalIF":2.2000,"publicationDate":"2021-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8605512/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s40463-021-00541-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The advent of 3D navigation imaging has opened new borders to the endoscopic surgical approaches of naso-sinusal inflammatory and neoplastic disease. This technology has gained in popularity among otolaryngologists for endoscopic sinus and skull base surgeries in both adults and children. However, the increased tissue radiation required for data acquisition associated with 3D navigation protocols CT scans is a source of concern because of its potential health hazards. We aimed to compare the effective doses of radiation between 3D navigation protocols and standard protocols for sinus computed tomography (CT) scans for both the adult and pediatric population.

Methods: We performed a retrospective cohort study through electronic chart review of patients undergoing sinus CT scans (standard and 3D navigation protocols) from May 2019 to December 2019 using a Siemens Drive (VA62A) CT scanner. The effective dose of radiation was calculated in mSv for all exams. Average irradiation doses were compared using a Student's T-Test or a Kruskall-Wallis test when appropriate.

Results: A total of 115 CT scans were selected for analysis, of which 47 were standard protocols and 68 were 3D navigation protocols CT scans. Among these, 31 exams were performed on children and 84 exams on adults. For the total population, mean effective dose in the non-navigation CT scans was 0.37 mSv (SD: 0.16, N = 47) and mean effective dose in the 3D navigation sinus CT group was 2.33 mSv (SD: 0.45, N = 68). The mean difference between the two groups was statistically significant 1.97 mSv (CI 95% - 2.1 to - 1.83; P < 0.0001). There was a sixfold increase in radiation with utilization of 3D navigation protocols. The ratio was identical when the pediatric as well as the adult subset of patients were analyzed.

Conclusion: In our center, utilization of 3D navigation sinus CT protocols significantly increases radiation exposure. Otolaryngologists should be aware of this significant increase and should attempt to decrease the radiation exposure of their patients by limiting unnecessary scan orders and by evaluating 3D acquisition protocols locally with radiation physicists.

Level of evidence: Level IV.

Abstract Image

Abstract Image

Abstract Image

鼻窦导航和非导航CT扫描:儿童和成人有效辐射剂量的比较。
背景:三维导航成像的出现为鼻-鼻窦炎症和肿瘤疾病的内镜手术入路开辟了新的边界。这项技术已经在耳鼻喉科医生中获得了普及,用于成人和儿童的内窥镜鼻窦和颅底手术。然而,与3D导航协议CT扫描相关的数据采集所需的组织辐射增加是一个令人担忧的问题,因为它具有潜在的健康危害。我们的目的是比较成人和儿童鼻窦计算机断层扫描的3D导航方案和标准方案之间的有效辐射剂量。方法:对2019年5月至2019年12月使用Siemens Drive (VA62A) CT扫描仪进行鼻窦CT扫描(标准和3D导航方案)的患者进行电子病历回顾,进行回顾性队列研究。所有检查的有效辐射剂量均以毫希沃特计算。在适当的情况下,使用学生t检验或Kruskall-Wallis检验比较平均辐照剂量。结果:共选择115张CT扫描图进行分析,其中47张为标准方案CT扫描图,68张为3D导航方案CT扫描图。其中,儿童31项,成人84项。总体而言,非导航CT组平均有效剂量为0.37 mSv (SD: 0.16, N = 47),三维导航窦CT组平均有效剂量为2.33 mSv (SD: 0.45, N = 68)。两组间的平均差异有统计学意义1.97 mSv (CI 95% - 2.1至- 1.83);P结论:在本中心,使用三维导航窦CT方案显著增加辐射暴露。耳鼻喉科医生应该意识到这种显著的增加,并应该通过限制不必要的扫描顺序和与放射物理学家评估当地的3D采集方案来减少患者的辐射暴露。证据等级:四级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书