A Comparison of Cardiac Computed Tomography, Transesophageal and Intracardiac Echocardiography, and Fluoroscopy for Planning Left Atrial Appendage Closure.
Pavel Osmancik, Dalibor Herman, Hana Linkova, Marek Hozman, Marek Labos
{"title":"A Comparison of Cardiac Computed Tomography, Transesophageal and Intracardiac Echocardiography, and Fluoroscopy for Planning Left Atrial Appendage Closure.","authors":"Pavel Osmancik, Dalibor Herman, Hana Linkova, Marek Hozman, Marek Labos","doi":"10.4022/jafib.20200449","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Left atrial appendage (LAA) closure (LAAC) is accompanied by a high risk of complications. Due to the complex anatomy of the LAA and the oval-shaped ostium, the proper sizing of the device is often difficult.</p><p><strong>Purpose: </strong>To assess individualized fluoroscopy viewing angles using pre-procedural CT analysis and to compare the results of landing zone measurements obtained from CT, transesophageal echocardiography (TEE), intracardiac echocardiography (ICE), and fluoroscopy.</p><p><strong>Methods: </strong>Patients with indications for LAAC were enrolled. Cardiac CT and TEE were done before the procedure; ICE and fluoroscopy measurements were done peri-procedurally. Multiplanar reconstruction of CT images, using FluoroCT software, was done, and optimal \"personalized\" viewing angles for fluoroscopy were determined. Moreover, a mean (using multiplanar CT reconstruction, derived from the LAA perimetr) amd maximum (using all four imaging modalitities) landing zone (LZ) of the LAA were masured.</p><p><strong>Results: </strong>Twenty-five patients were analyzed. Despite significant correlation between LZs obtained from different imaging modalities, the values of LZs differed significantly; the mean LZ diameter on CT was 20.60 ± 3.42 mm, the maximum diameters were 21.99 ± 4.03 mm (CT), 18.72 ± 2.44 mm (TEE), 18.20 ± 2.68 mm (ICE), and 17.76 ± 3.24 mm (fluoroscopy). The mean CT diameter matched with the final device selection in 92% patients, while fluoroscopy or TEE maximum diameters in only 72% patients. Optimal viewing angles differed significantly from the fluoroscopy projections usually recommended by the manufacturer in 3 patients.</p><p><strong>Conclusions: </strong>CT provides the best measurement of the LZ and the best prediction of the optimum fluoroscopy projections for the implantation procedure.</p>","PeriodicalId":15072,"journal":{"name":"Journal of atrial fibrillation","volume":"13 6","pages":"20200449"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8691285/pdf/jafib-13-20200449.pdf","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of atrial fibrillation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4022/jafib.20200449","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/4/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 7
Abstract
Background: Left atrial appendage (LAA) closure (LAAC) is accompanied by a high risk of complications. Due to the complex anatomy of the LAA and the oval-shaped ostium, the proper sizing of the device is often difficult.
Purpose: To assess individualized fluoroscopy viewing angles using pre-procedural CT analysis and to compare the results of landing zone measurements obtained from CT, transesophageal echocardiography (TEE), intracardiac echocardiography (ICE), and fluoroscopy.
Methods: Patients with indications for LAAC were enrolled. Cardiac CT and TEE were done before the procedure; ICE and fluoroscopy measurements were done peri-procedurally. Multiplanar reconstruction of CT images, using FluoroCT software, was done, and optimal "personalized" viewing angles for fluoroscopy were determined. Moreover, a mean (using multiplanar CT reconstruction, derived from the LAA perimetr) amd maximum (using all four imaging modalitities) landing zone (LZ) of the LAA were masured.
Results: Twenty-five patients were analyzed. Despite significant correlation between LZs obtained from different imaging modalities, the values of LZs differed significantly; the mean LZ diameter on CT was 20.60 ± 3.42 mm, the maximum diameters were 21.99 ± 4.03 mm (CT), 18.72 ± 2.44 mm (TEE), 18.20 ± 2.68 mm (ICE), and 17.76 ± 3.24 mm (fluoroscopy). The mean CT diameter matched with the final device selection in 92% patients, while fluoroscopy or TEE maximum diameters in only 72% patients. Optimal viewing angles differed significantly from the fluoroscopy projections usually recommended by the manufacturer in 3 patients.
Conclusions: CT provides the best measurement of the LZ and the best prediction of the optimum fluoroscopy projections for the implantation procedure.
背景:左心耳(LAA)闭合术(LAAC)伴有并发症的高风险。由于LAA和椭圆形开口的复杂解剖结构,设备的适当尺寸通常是困难的。目的:通过术前CT分析评估个体化透视视角,并比较CT、经食管超声心动图(TEE)、心内超声心动图(ICE)和透视获得的着陆区测量结果。方法:纳入符合LAAC适应症的患者。术前行心脏CT、TEE检查;术中进行ICE和透视测量。使用FluoroCT软件对CT图像进行多平面重建,并确定最佳的“个性化”透视视角。此外,测量了LAA的平均(使用多平面CT重建,由LAA周长导出)和最大(使用所有四种成像方式)着陆区(LZ)。结果:对25例患者进行分析。尽管不同成像方式的LZs之间存在显著相关性,但LZs的数值差异显著;CT上LZ平均直径为20.60±3.42 mm,最大直径分别为21.99±4.03 mm (CT)、18.72±2.44 mm (TEE)、18.20±2.68 mm (ICE)、17.76±3.24 mm(透视)。92%患者的平均CT直径与最终装置选择相匹配,而透视或TEE最大直径仅为72%。3例患者的最佳视角与制造商通常推荐的透视投影明显不同。结论:CT提供了最佳的LZ测量和最佳的透视投影预测。