THE NOVEL USE OF HIGH-FLOW POLYIMIDE CANNULAS TO IMPROVE SILICONE OIL INJECTABILITY IN VITREORETINAL SURGERY.

Maximilian Hammer, Sonja K Schickhardt, Donald Munro, Ramin Khoramnia, Alexander Scheuerle, Christian S Mayer, Gerd U Auffarth
{"title":"THE NOVEL USE OF HIGH-FLOW POLYIMIDE CANNULAS TO IMPROVE SILICONE OIL INJECTABILITY IN VITREORETINAL SURGERY.","authors":"Maximilian Hammer,&nbsp;Sonja K Schickhardt,&nbsp;Donald Munro,&nbsp;Ramin Khoramnia,&nbsp;Alexander Scheuerle,&nbsp;Christian S Mayer,&nbsp;Gerd U Auffarth","doi":"10.1097/IAE.0000000000003432","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The injection of high-viscosity silicone oil lengthens injection time. New polyimide cannulas offer a greater inner diameter than conventional metal cannulas at the same gauge. We compared the injection time for polyimide and metal cannulas at 23 G for a variety of silicone oils including a 12,500-mPas prototype oil.</p><p><strong>Methods: </strong>In this laboratory study, injection time was measured three times per cannula and per oil. Warming the oil before injection to up to 42°C was also evaluated. Finally, the feasibility of polyimide cannulas was tested in vitrectomized porcine eyes.</p><p><strong>Results: </strong>The 23-G polyimide cannula mostly decreased injection times. The time to inject 5 mL of Siluron Xtra and Siluron 5000 decreased by 6:02 (76.9%) minutes (483 vs. 121 seconds) and 12:01 (74.7%) minutes (973 vs. 252 seconds), respectively. Although the 23-G metal cannula failed to inject 12,500 mPas oil, 5 mL was injected in 10:21 minutes using the polyimide cannula. Prewarming Siluron 5000 to 42°C lowered the injection time by 9.0% and by 12.1% when using the metal or polyimide cannula, respectively.</p><p><strong>Conclusion: </strong>Polyimide cannulas allow a clinically relevant decrease in injection time. They may not only shorten surgery time but could also ease the use of next-generation ultra-high-viscosity silicone oils. Prewarming silicone oil leads to decreased injection times.</p>","PeriodicalId":377573,"journal":{"name":"Retina (Philadelphia, Pa.)","volume":" ","pages":"1170-1175"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Retina (Philadelphia, Pa.)","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/IAE.0000000000003432","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Purpose: The injection of high-viscosity silicone oil lengthens injection time. New polyimide cannulas offer a greater inner diameter than conventional metal cannulas at the same gauge. We compared the injection time for polyimide and metal cannulas at 23 G for a variety of silicone oils including a 12,500-mPas prototype oil.

Methods: In this laboratory study, injection time was measured three times per cannula and per oil. Warming the oil before injection to up to 42°C was also evaluated. Finally, the feasibility of polyimide cannulas was tested in vitrectomized porcine eyes.

Results: The 23-G polyimide cannula mostly decreased injection times. The time to inject 5 mL of Siluron Xtra and Siluron 5000 decreased by 6:02 (76.9%) minutes (483 vs. 121 seconds) and 12:01 (74.7%) minutes (973 vs. 252 seconds), respectively. Although the 23-G metal cannula failed to inject 12,500 mPas oil, 5 mL was injected in 10:21 minutes using the polyimide cannula. Prewarming Siluron 5000 to 42°C lowered the injection time by 9.0% and by 12.1% when using the metal or polyimide cannula, respectively.

Conclusion: Polyimide cannulas allow a clinically relevant decrease in injection time. They may not only shorten surgery time but could also ease the use of next-generation ultra-high-viscosity silicone oils. Prewarming silicone oil leads to decreased injection times.

新型高流量聚酰亚胺套管改善玻璃体视网膜手术中硅油的可注射性。
目的:注射高粘度硅油延长注射时间。新型聚酰亚胺套管比相同口径的传统金属套管具有更大的内径。我们比较了聚酰亚胺和金属套管在23 G下对各种硅油的注射时间,包括12500 - mpas的原型油。方法:在本实验室研究中,测量注射时间,每个套管和每个油三次。在注射前将油加热至42°C也进行了评估。最后,在玻璃体切除的猪眼中验证了聚酰亚胺套管的可行性。结果:23-G聚酰亚胺套管明显减少注射次数。注射5ml Siluron Xtra和Siluron 5000所需时间分别缩短了6:02 (76.9%)min (483 vs. 121 s)和12:01 (74.7%)min (973 vs. 252 s)。23-G金属套管虽然未能注入12500 mPas油,但聚酰亚胺套管在10:21分钟内注入了5 mL。将Siluron 5000预热至42℃,使用金属套管或聚酰亚胺套管时,注射时间分别缩短9.0%和12.1%。结论:聚酰亚胺套管可减少临床相关的注射时间。它们不仅可以缩短手术时间,还可以简化下一代超高粘度硅油的使用。预热硅油可减少注射次数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信