Julien Francisco Zaldivar-Jolissaint, François Lechanoine, Bernard Krummenacher, Rivus Ferreira Arruda, Lukas Bobinski, Emmanuel de Schlichting, John Michael Duff
{"title":"Using Smartphones for Clinical Assessment in Cervical Spondylotic Myelopathy a Feasibility Study.","authors":"Julien Francisco Zaldivar-Jolissaint, François Lechanoine, Bernard Krummenacher, Rivus Ferreira Arruda, Lukas Bobinski, Emmanuel de Schlichting, John Michael Duff","doi":"10.1115/1.4052609","DOIUrl":null,"url":null,"abstract":"<p><p>Degenerative cervical myelopathy (DCM) is characterized by a progressive deterioration in spinal cord function. Its evaluation requires subjective clinical examination with wide interobserver variability. Objective quantification of spinal cord function remains imprecise, even though validated myelopathy-grading scales have emerged and are now widely used. We created a Smartphone Application, the N-Outcome App, with the aim of quantifying accurately and reliably spinal cord dysfunction using a 5-minute Test. A patient suffering from DCM was clinically evaluated before surgery, at 3 and 6 months follow-up after surgical decompression of the cervical spinal cord. Standard scores (Nurick grade, modified Japanese Orthopedic Association (mJOA) score) were documented at these time points. A 5-minute motor and proprioceptive performance test aided by a smartphone with the N-outcome App was also performed. Motor performance in rapid alternating movements and finger tapping improved in correlation with improvements in standard grading scale scores. Clinical improvements were seen in maximum reflex acceleration and in Romberg testing which showed less closed/open eyes variation, suggesting pyramidal and proprioceptive function recovery. We demonstrate that using the N-Outcome App as an adjunct to clinical evaluation of compressive myelopathy is feasible and potentially useful. The results correlate with the results of clinical assessment obtained by standard validated myelopathy scores.</p>","PeriodicalId":49305,"journal":{"name":"Journal of Medical Devices-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8822463/pdf/med-20-1212_044503.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4052609","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/10/22 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 1
Abstract
Degenerative cervical myelopathy (DCM) is characterized by a progressive deterioration in spinal cord function. Its evaluation requires subjective clinical examination with wide interobserver variability. Objective quantification of spinal cord function remains imprecise, even though validated myelopathy-grading scales have emerged and are now widely used. We created a Smartphone Application, the N-Outcome App, with the aim of quantifying accurately and reliably spinal cord dysfunction using a 5-minute Test. A patient suffering from DCM was clinically evaluated before surgery, at 3 and 6 months follow-up after surgical decompression of the cervical spinal cord. Standard scores (Nurick grade, modified Japanese Orthopedic Association (mJOA) score) were documented at these time points. A 5-minute motor and proprioceptive performance test aided by a smartphone with the N-outcome App was also performed. Motor performance in rapid alternating movements and finger tapping improved in correlation with improvements in standard grading scale scores. Clinical improvements were seen in maximum reflex acceleration and in Romberg testing which showed less closed/open eyes variation, suggesting pyramidal and proprioceptive function recovery. We demonstrate that using the N-Outcome App as an adjunct to clinical evaluation of compressive myelopathy is feasible and potentially useful. The results correlate with the results of clinical assessment obtained by standard validated myelopathy scores.
期刊介绍:
The Journal of Medical Devices presents papers on medical devices that improve diagnostic, interventional and therapeutic treatments focusing on applied research and the development of new medical devices or instrumentation. It provides special coverage of novel devices that allow new surgical strategies, new methods of drug delivery, or possible reductions in the complexity, cost, or adverse results of health care. The Design Innovation category features papers focusing on novel devices, including papers with limited clinical or engineering results. The Medical Device News section provides coverage of advances, trends, and events.