Benny Johansson, Espen Fengsrud, Fredrik Lundin, Leif Bojö, Dritan Poci
{"title":"The a' velocity by tissue-Doppler echocardiography correlates to invasive mean left atrial pressure in patients with normal ejection fraction.","authors":"Benny Johansson, Espen Fengsrud, Fredrik Lundin, Leif Bojö, Dritan Poci","doi":"10.1080/14017431.2022.2032317","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the correlation of a' velocity by tissue-Doppler measurements with invasively measured mean left atrial pressure in patients with normal ejection fraction.</p><p><strong>Design: </strong>In this retrospective study, we evaluated the septal a', lateral a' and average a' velocity by tissue-Doppler echocardiography, in 125 in-hospital patients, 1-12 h before an elective pulmonary vein isolation due to intermittent atrial fibrillation, and compared to invasively measured mean left atrial pressure (LAP) during the invasive procedure. The patients, aged 35-81 years, had to be in sinus rhythm at both examinations, no atrial fibrillation during two procedures, no or mild valve disease and normal ejection fraction (>50%).</p><p><strong>Results: </strong>Invasively measured mean LAP correlated well to septal a' (<i>r</i> = -0.435), lateral a' (<i>r</i> = -0.473) and average a' velocity (<i>r</i> = -0.491). Normal mean LAP (≤12 mmHg) was found in 95 patients and elevated mean LAP (>12 mmHg) in 30 patients. The patients with elevated mean LAP had a lower septal a' velocity (6.5 ± 2.7 vs 8.6 ± 2.3 cm/s; <i>p</i> < .01), lateral a' velocity (5.9 ± 2.3 vs 8.6 ± 2.1 cm/s; <i>p</i> < .01) and average a' velocity (6.2 ± 2.4 vs 8.8 ± 2.1 cm/s; <i>p</i> < .01) compared to patients with normal mean LAP. Septal a', lateral a' and average a' velocity were good predictors of elevated mean LAP with AUC of 0.78, 0.83 and 0.82. Average a' velocity with cut-off < 7.25 cm/s had a sensitivity of 83% and a specificity of 77% to predict elevated mean LAP.</p><p><strong>Conclusion: </strong>The a' velocity is a good indicator of mean LAP and might be considered in the evaluation of left ventricle filling pressure in patients with normal ejection fraction.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/14017431.2022.2032317","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/2/9 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 1
Abstract
Objectives: To evaluate the correlation of a' velocity by tissue-Doppler measurements with invasively measured mean left atrial pressure in patients with normal ejection fraction.
Design: In this retrospective study, we evaluated the septal a', lateral a' and average a' velocity by tissue-Doppler echocardiography, in 125 in-hospital patients, 1-12 h before an elective pulmonary vein isolation due to intermittent atrial fibrillation, and compared to invasively measured mean left atrial pressure (LAP) during the invasive procedure. The patients, aged 35-81 years, had to be in sinus rhythm at both examinations, no atrial fibrillation during two procedures, no or mild valve disease and normal ejection fraction (>50%).
Results: Invasively measured mean LAP correlated well to septal a' (r = -0.435), lateral a' (r = -0.473) and average a' velocity (r = -0.491). Normal mean LAP (≤12 mmHg) was found in 95 patients and elevated mean LAP (>12 mmHg) in 30 patients. The patients with elevated mean LAP had a lower septal a' velocity (6.5 ± 2.7 vs 8.6 ± 2.3 cm/s; p < .01), lateral a' velocity (5.9 ± 2.3 vs 8.6 ± 2.1 cm/s; p < .01) and average a' velocity (6.2 ± 2.4 vs 8.8 ± 2.1 cm/s; p < .01) compared to patients with normal mean LAP. Septal a', lateral a' and average a' velocity were good predictors of elevated mean LAP with AUC of 0.78, 0.83 and 0.82. Average a' velocity with cut-off < 7.25 cm/s had a sensitivity of 83% and a specificity of 77% to predict elevated mean LAP.
Conclusion: The a' velocity is a good indicator of mean LAP and might be considered in the evaluation of left ventricle filling pressure in patients with normal ejection fraction.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.