Radiographic union score for tibia (RUST) scoring system in adult diaphyseal femoral fractures treated with intramedullary nailing: an assessment of interobserver and intraobserver reliability.

IF 1.5
Pravesh Panchoo, Maritz Laubscher, Michael Held, Sithombo Maqungo, Nando Ferreira, Hamish Simpson, Simon Matthew Graham
{"title":"Radiographic union score for tibia (RUST) scoring system in adult diaphyseal femoral fractures treated with intramedullary nailing: an assessment of interobserver and intraobserver reliability.","authors":"Pravesh Panchoo, Maritz Laubscher, Michael Held, Sithombo Maqungo, Nando Ferreira, Hamish Simpson, Simon Matthew Graham","doi":"10.1007/s00590-021-03134-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The Radiographic Union Score for Tibia (RUST) scoring system has been validated in multiple studies assessing the healing of tibial fractures. Our objective was to assess the interobserver and intraobserver reliability for the RUST in diaphyseal femoral fractures treated with intramedullary (IM) nailing.</p><p><strong>Patients and methods: </strong>A total of 60 sets of anteroposterior (AP) and lateral radiographs of diaphyseal femoral fractures treated by reamed IM nailing were randomly selected from a prospectively collected database. The 60 sets of radiographs were then scored by three reviewers using the RUST system. Interobserver reliability was measured at initial scoring. The 60 sets of radiographs were scored again by the three reviewers to calculate the intraobserver reliability.</p><p><strong>Results: </strong>The RUST scores ranged from 4 to 12 with a mean score of 11.3 ± 1.3. The interobserver intraclass correlation coefficient (ICC) was 0.87 (95% CI, 0.81-0.92) and the intraobserver ICC was 0.91 (95% CI, 0.88-0.94), which indicated excellent agreement.</p><p><strong>Conclusion: </strong>This study demonstrated that the RUST system can be used reliably in the assessment of healing in diaphyseal femur fractures treated by reamed intramedullary nailing, with excellent interobserver and intraobserver reliability.</p>","PeriodicalId":520619,"journal":{"name":"European journal of orthopaedic surgery & traumatology : orthopedie traumatologie","volume":" ","pages":"1555-1559"},"PeriodicalIF":1.5000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of orthopaedic surgery & traumatology : orthopedie traumatologie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00590-021-03134-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/10/1 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The Radiographic Union Score for Tibia (RUST) scoring system has been validated in multiple studies assessing the healing of tibial fractures. Our objective was to assess the interobserver and intraobserver reliability for the RUST in diaphyseal femoral fractures treated with intramedullary (IM) nailing.

Patients and methods: A total of 60 sets of anteroposterior (AP) and lateral radiographs of diaphyseal femoral fractures treated by reamed IM nailing were randomly selected from a prospectively collected database. The 60 sets of radiographs were then scored by three reviewers using the RUST system. Interobserver reliability was measured at initial scoring. The 60 sets of radiographs were scored again by the three reviewers to calculate the intraobserver reliability.

Results: The RUST scores ranged from 4 to 12 with a mean score of 11.3 ± 1.3. The interobserver intraclass correlation coefficient (ICC) was 0.87 (95% CI, 0.81-0.92) and the intraobserver ICC was 0.91 (95% CI, 0.88-0.94), which indicated excellent agreement.

Conclusion: This study demonstrated that the RUST system can be used reliably in the assessment of healing in diaphyseal femur fractures treated by reamed intramedullary nailing, with excellent interobserver and intraobserver reliability.

成人股骨骨干骨折髓内钉治疗的胫骨放射学愈合评分(RUST)评分系统:观察者间和观察者内可靠性的评估。
目的:胫骨放射联合评分(RUST)评分系统已在评估胫骨骨折愈合的多项研究中得到验证。我们的目的是评估用髓内钉治疗股骨骨干骨折的RUST在观察者间和观察者内的可靠性。患者和方法:从前瞻性收集的数据库中随机选择经扩孔内钉治疗股骨骨干骨折的60组正位和侧位x线片。然后由三名评论者使用RUST系统对60套x线片进行评分。在初始评分时测量观察者间信度。这60组x线片再次由三位评论者打分,计算观察者内信度。结果:RUST评分范围为4 ~ 12分,平均11.3±1.3分。观察者间类内相关系数(ICC)为0.87 (95% CI, 0.81-0.92),观察者内相关系数(ICC)为0.91 (95% CI, 0.88-0.94),表明极好的一致性。结论:本研究表明RUST系统可可靠地用于评估扩孔髓内钉治疗骨干股骨骨折的愈合情况,具有良好的观察者间和观察者内可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书