A Density Comparison of Silicon Artifacts Between NML (Australia) and NBS (U.S.).

J B Patterson, R S Davis
{"title":"A Density Comparison of Silicon Artifacts Between NML (Australia) and NBS (U.S.).","authors":"J B Patterson,&nbsp;R S Davis","doi":"10.6028/jres.090.016","DOIUrl":null,"url":null,"abstract":"<p><p>The densities of four silicon artifacts were measured in SI units to 1 × 10<sup>-6</sup> by NML (Australia) and NBS (U.S.). Agreement is within the experimental uncertainty of each laboratory. Two of the artifacts had been used in the determination of the Avogadro constant at NBS. The remaining two objects had been used at NBS to establish silicon density artifacts available as a Standard Reference Material (SRM).</p>","PeriodicalId":93321,"journal":{"name":"Journal of research of the National Bureau of Standards (1977)","volume":"90 4","pages":"285-287"},"PeriodicalIF":0.0000,"publicationDate":"1985-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6692281/pdf/jres-90-285.pdf","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of research of the National Bureau of Standards (1977)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6028/jres.090.016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The densities of four silicon artifacts were measured in SI units to 1 × 10-6 by NML (Australia) and NBS (U.S.). Agreement is within the experimental uncertainty of each laboratory. Two of the artifacts had been used in the determination of the Avogadro constant at NBS. The remaining two objects had been used at NBS to establish silicon density artifacts available as a Standard Reference Material (SRM).

NML(澳大利亚)和NBS(美国)之间硅伪影的密度比较。
NML(澳大利亚)和NBS(美国)测量了四种硅伪影的密度,单位为1×10-6。协议在每个实验室的实验不确定性范围内。其中两个伪像已用于NBS的阿伏伽德罗常数的测定。剩下的两个物体已在国家统计局用于建立可用作标准参考材料(SRM)的硅密度伪影。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信