Comparing the Efficacy of Radiation Free Machine-Vision Image-Guided Surgery With Traditional 2-Dimensional Fluoroscopy: A Randomized, Single-Center Study.

Jessica Dorilio, Nicole Utah, Christina Dowe, Fedan Avrumova, Daniel Alicea, Antonio Brecevich, Tucker Callanan, Andrew Sama, Darren R Lebl, Celeste Abjornson, Frank P Cammisa
{"title":"Comparing the Efficacy of Radiation Free Machine-Vision Image-Guided Surgery With Traditional 2-Dimensional Fluoroscopy: A Randomized, Single-Center Study.","authors":"Jessica Dorilio,&nbsp;Nicole Utah,&nbsp;Christina Dowe,&nbsp;Fedan Avrumova,&nbsp;Daniel Alicea,&nbsp;Antonio Brecevich,&nbsp;Tucker Callanan,&nbsp;Andrew Sama,&nbsp;Darren R Lebl,&nbsp;Celeste Abjornson,&nbsp;Frank P Cammisa","doi":"10.1177/15563316211029837","DOIUrl":null,"url":null,"abstract":"<p><p><i>Background:</i> Three-dimensional (3D) computer-assisted navigation (CAN) has emerged as a potential alternative to 2-dimensional (2D) fluoroscopy in the surgical placement of spinal instrumentation. Recently, 3D-CAN systems have improved significantly in their ability to provide real-time anatomical referencing while shortening the registration and set-up time. A novel system in navigation, Machine-Vision Image-Guided Surgery (MvIGS; 7D Surgical, Toronto, Canada) was cleared by the US Food and Drug Administration, but its potential benefits in reducing intra-operative radiation exposure to patients and enhancing surgical accuracy of pedicle screw placement are not fully known. <i>Purpose</i>: We sought to conduct a prospective, randomized, clinical study comparing the 3D-MvIGS spinal navigation system and 2D-fluoroscopy for pedicle screw insertion up to 3 levels (T10-S1) and for various measures of surgical efficacy. <i>Methods</i>: Sixty-two eligible patients were randomized to receive spine surgery using either the 3D-MvIGS group or the conventional 2D-fluoroscopy for pedicle screw fixation for the treatment of spinal stenosis and degenerative spondylolisthesis. Intra-operative parameters and procedure-related unintended protocol violations were recorded. <i>Results</i>: Operative time and estimated blood loss were not significantly different between groups. Radiation time and exposure to patients were significantly reduced in the 3D-MvIGS group. There was no difference between groups in pedicle screw placement accuracy (2D-fluoroscopy group, 96.6%; 3D-MvIGS group, 94.2%). There were no major complications or cases that required revision surgery. <i>Conclusion</i>: The 3D-MvIGS navigation system performed comparably with 2D-fluoroscopy in terms of pedicle screw placement accuracy and operative time. The 3D-MvIGS showed a significant reduction in radiation exposure to patients. In more complex cases or larger cohorts, the true value of greater anatomical visualization can be elucidated.</p>","PeriodicalId":253125,"journal":{"name":"HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery","volume":"17 3","pages":"274-280"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/15563316211029837","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15563316211029837","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/7/14 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Background: Three-dimensional (3D) computer-assisted navigation (CAN) has emerged as a potential alternative to 2-dimensional (2D) fluoroscopy in the surgical placement of spinal instrumentation. Recently, 3D-CAN systems have improved significantly in their ability to provide real-time anatomical referencing while shortening the registration and set-up time. A novel system in navigation, Machine-Vision Image-Guided Surgery (MvIGS; 7D Surgical, Toronto, Canada) was cleared by the US Food and Drug Administration, but its potential benefits in reducing intra-operative radiation exposure to patients and enhancing surgical accuracy of pedicle screw placement are not fully known. Purpose: We sought to conduct a prospective, randomized, clinical study comparing the 3D-MvIGS spinal navigation system and 2D-fluoroscopy for pedicle screw insertion up to 3 levels (T10-S1) and for various measures of surgical efficacy. Methods: Sixty-two eligible patients were randomized to receive spine surgery using either the 3D-MvIGS group or the conventional 2D-fluoroscopy for pedicle screw fixation for the treatment of spinal stenosis and degenerative spondylolisthesis. Intra-operative parameters and procedure-related unintended protocol violations were recorded. Results: Operative time and estimated blood loss were not significantly different between groups. Radiation time and exposure to patients were significantly reduced in the 3D-MvIGS group. There was no difference between groups in pedicle screw placement accuracy (2D-fluoroscopy group, 96.6%; 3D-MvIGS group, 94.2%). There were no major complications or cases that required revision surgery. Conclusion: The 3D-MvIGS navigation system performed comparably with 2D-fluoroscopy in terms of pedicle screw placement accuracy and operative time. The 3D-MvIGS showed a significant reduction in radiation exposure to patients. In more complex cases or larger cohorts, the true value of greater anatomical visualization can be elucidated.

Abstract Image

Abstract Image

比较无辐射机器视觉图像引导手术与传统二维透视术的疗效:一项随机、单中心研究。
背景:三维(3D)计算机辅助导航(CAN)已成为脊柱内固定手术中二维(2D)透视的潜在替代方案。最近,3D-CAN系统在提供实时解剖参考的能力方面有了显着提高,同时缩短了注册和设置时间。一种新的导航系统,机器视觉图像引导手术(MvIGS);7D Surgical, Toronto, Canada)已获得美国食品和药物管理局的批准,但其在减少术中对患者的辐射暴露和提高椎弓根螺钉置入的手术准确性方面的潜在益处尚不完全清楚。目的:我们试图进行一项前瞻性、随机、临床研究,比较3D-MvIGS脊柱导航系统和2d -透视技术在3节段(T10-S1)椎弓根螺钉置入和各种手术疗效的测量。方法:将62例符合条件的患者随机分为两组,一组采用3D-MvIGS组,另一组采用传统的2d透视椎弓根螺钉固定治疗椎管狭窄和退行性椎体滑脱。记录术中参数和与程序相关的意外协议违反。结果:两组间手术时间及估计失血量无显著差异。3D-MvIGS组患者的辐射时间和暴露量显著减少。两组间椎弓根螺钉置入准确率无差异(2d透视组为96.6%;3D-MvIGS组,94.2%)。没有重大并发症,也没有需要翻修手术的病例。结论:3D-MvIGS导航系统在椎弓根螺钉放置精度和手术时间方面与2d -透视具有可比性。3D-MvIGS显示患者的辐射暴露显著减少。在更复杂的病例或更大的队列中,更大的解剖可视化的真正价值可以阐明。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书