Workflow and Efficiency of Robotic-Assisted Navigation in Spine Surgery.

Fedan Avrumova, Ahilan Sivaganesan, Ram Kiran Alluri, Avani Vaishnav, Sheeraz Qureshi, Darren R Lebl
{"title":"Workflow and Efficiency of Robotic-Assisted Navigation in Spine Surgery.","authors":"Fedan Avrumova, Ahilan Sivaganesan, Ram Kiran Alluri, Avani Vaishnav, Sheeraz Qureshi, Darren R Lebl","doi":"10.1177/15563316211026658","DOIUrl":null,"url":null,"abstract":"The increasing interest in improving intraoperative workflow and efficiency is evident from the growing body of literature on spinal robotics. The first robotic-assisted system for adult spine surgery received US Food and Drug Administration (FDA) clearance in 2004 [4]. Newer robotic systems with integrated surgical navigation have shown the potential for improved accuracy, shorter time-per-screw placement, less fluoroscopy/radiation time, and shorter hospital stays over freehand techniques [8,9]. One early iteration, the Mazor SpineAssist system, provided 6° of freedom of mobility for surgical instrumentation in addition to close to optimal screw positioning and placement [5]. Mazor Robotics released the second generation (Renaissance Guidance System) in 2011, which was followed by the third generation (Mazor X) in 2016. (Mazor Robotics was purchased by Medtronic in 2018.) The most recent version is the Mazor X Stealth Edition; first used in 2019, it combines navigation and robotics in a single platform [5]. Recent competitors include ExcelsiusGPS (Globus Medical, Inc., Audubon, PA, USA), ROSA Spine (Zimmer Biomet Robotics, formerly Medtech SA, Montpellier, France), and Cirq (BrainLab, Munich, Germany) [12]. While multiple studies have examined the operative metrics of robotic-assisted surgery, few have offered a practical understanding of the types of surgeries that can be performed using various systems and the intraoperative workflows required. Here we review these issues, with the aim of providing a foundation for surgeons seeking to incorporate robotics into their practice in an efficient manner. We focus on the Mazor X Robotic Guidance System and the ExcelsiusGPS Robotic Navigation Platform; each has a different physical relationship to the operating room table. The Mazor X is a table-mounted system while the ExcelsiusGPS is a freestanding system with optical arrays. The Mazor X has an inherent stability due to its physical connection to the patient but, due to the weight of the bedmounted arm, it cannot maintain that stability if the patient’s position changes. In addition, a 2 to 3 mm incision must be made on the patient’s right side for posterior superior iliac spine (PSIS) pin placement. In contrast, the ExcelsiusGPS is a freestanding system that does not attach to either the bed or the patient. This allows the patient to change positions without interfering with robotic arm stability. The ROSA Spine received FDA clearance in 2016, and BrainLab’s Cirq received FDA clearance in 2019. Similar to the ExcelsiusGPS, ROSA is a freestanding system that uses a robotic arm and navigation camera, each mounted to mobile bases. BrainLab Cirq is similar to the Mazor X, as it is table-mounted.","PeriodicalId":253125,"journal":{"name":"HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery","volume":"17 3","pages":"302-307"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/15563316211026658","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15563316211026658","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/6/29 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

The increasing interest in improving intraoperative workflow and efficiency is evident from the growing body of literature on spinal robotics. The first robotic-assisted system for adult spine surgery received US Food and Drug Administration (FDA) clearance in 2004 [4]. Newer robotic systems with integrated surgical navigation have shown the potential for improved accuracy, shorter time-per-screw placement, less fluoroscopy/radiation time, and shorter hospital stays over freehand techniques [8,9]. One early iteration, the Mazor SpineAssist system, provided 6° of freedom of mobility for surgical instrumentation in addition to close to optimal screw positioning and placement [5]. Mazor Robotics released the second generation (Renaissance Guidance System) in 2011, which was followed by the third generation (Mazor X) in 2016. (Mazor Robotics was purchased by Medtronic in 2018.) The most recent version is the Mazor X Stealth Edition; first used in 2019, it combines navigation and robotics in a single platform [5]. Recent competitors include ExcelsiusGPS (Globus Medical, Inc., Audubon, PA, USA), ROSA Spine (Zimmer Biomet Robotics, formerly Medtech SA, Montpellier, France), and Cirq (BrainLab, Munich, Germany) [12]. While multiple studies have examined the operative metrics of robotic-assisted surgery, few have offered a practical understanding of the types of surgeries that can be performed using various systems and the intraoperative workflows required. Here we review these issues, with the aim of providing a foundation for surgeons seeking to incorporate robotics into their practice in an efficient manner. We focus on the Mazor X Robotic Guidance System and the ExcelsiusGPS Robotic Navigation Platform; each has a different physical relationship to the operating room table. The Mazor X is a table-mounted system while the ExcelsiusGPS is a freestanding system with optical arrays. The Mazor X has an inherent stability due to its physical connection to the patient but, due to the weight of the bedmounted arm, it cannot maintain that stability if the patient’s position changes. In addition, a 2 to 3 mm incision must be made on the patient’s right side for posterior superior iliac spine (PSIS) pin placement. In contrast, the ExcelsiusGPS is a freestanding system that does not attach to either the bed or the patient. This allows the patient to change positions without interfering with robotic arm stability. The ROSA Spine received FDA clearance in 2016, and BrainLab’s Cirq received FDA clearance in 2019. Similar to the ExcelsiusGPS, ROSA is a freestanding system that uses a robotic arm and navigation camera, each mounted to mobile bases. BrainLab Cirq is similar to the Mazor X, as it is table-mounted.
脊柱外科中机器人辅助导航的工作流程和效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书