Diagnostic Performances of Three Rapid Diagnostic Tests for Detecting HIV Infections in Mali.

Infectious diseases diagnosis & treatment Pub Date : 2019-01-01 Epub Date: 2019-12-18
Bourahima Kone, Yeya S Sarro, Bocar Baya, Djeneba Dabitao, Nadie Coulibaly, Mamadou Wague, Bassirou Diarra, Oumar Guindo, Moumine Sanogo, Antieme Cg Togo, Amadou Kone, Drissa Goita, Seydou Diabate, Ousmane Kodio, Michael Belson, Sounkalo Dao, Susan Orsega, Robert L Murphy, Souleymane Diallo, Seydou Doumbia, Sophia Siddiqui, Mamoudou Maiga
{"title":"Diagnostic Performances of Three Rapid Diagnostic Tests for Detecting HIV Infections in Mali.","authors":"Bourahima Kone, Yeya S Sarro, Bocar Baya, Djeneba Dabitao, Nadie Coulibaly, Mamadou Wague, Bassirou Diarra, Oumar Guindo, Moumine Sanogo, Antieme Cg Togo, Amadou Kone, Drissa Goita, Seydou Diabate, Ousmane Kodio, Michael Belson, Sounkalo Dao, Susan Orsega, Robert L Murphy, Souleymane Diallo, Seydou Doumbia, Sophia Siddiqui, Mamoudou Maiga","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Diagnosis of HIV infections in resource-limited countries like Mali is based on Rapid Diagnostic Tests (RDTs). The RDTs are diagnostic assays designed for use at the Point-Of-Care (POC), which is quick, cost-effective and easy to perform. However, in these countries, the tests are commonly used without any initial evaluation or monitoring of their performance despite high levels of HIV strain diversity and rapid evolution of the virus. In this study, the reliability and accuracy of HIV RDTs (Determine<sup>™</sup>, Multispot<sup>™</sup>, SD Bioline<sup>™</sup>) used in Mali, where HIV-1 and HIV-2 co-exist, were evaluated from August 2004 to November 2017. A total of 1303 samples from new HIV-suspect patients in Bamako were tested for HIV-1 and HIV-2 using the RDT Determine<sup>™</sup>, followed by ELISA and Western Blot (WB). The Determine<sup>™</sup> test showed a robust diagnostic sensitivity of 98.7% [CI 95: 97.59-99.37] and a diagnostic specificity of 99.2% [CI 95: 98.22-99.67]. The Multispot<sup>™</sup> assay showed a diagnostic sensitivity of 98.77% [CI 95: 97.59-99.37] and a diagnostic specificity of 99.2% [CI 95: 98.22-99.67]. The diagnostic sensitivity and specificity of SD Bioline<sup>™</sup> HIV-1/2 were 100% [CI 95:72.25-100] and 88.89% [CI 95: 56.50- 98.71], respectively. These data indicate excellent performance for HIV RDTs in Mali and we recommend the use of Determine<sup>™</sup> HIV-1/2 for HIV screening and Multispot™ for discriminating HIV-2 from HIV-1 infections.</p>","PeriodicalId":93299,"journal":{"name":"Infectious diseases diagnosis & treatment","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8336946/pdf/nihms-1565194.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infectious diseases diagnosis & treatment","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/12/18 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Diagnosis of HIV infections in resource-limited countries like Mali is based on Rapid Diagnostic Tests (RDTs). The RDTs are diagnostic assays designed for use at the Point-Of-Care (POC), which is quick, cost-effective and easy to perform. However, in these countries, the tests are commonly used without any initial evaluation or monitoring of their performance despite high levels of HIV strain diversity and rapid evolution of the virus. In this study, the reliability and accuracy of HIV RDTs (Determine, Multispot, SD Bioline) used in Mali, where HIV-1 and HIV-2 co-exist, were evaluated from August 2004 to November 2017. A total of 1303 samples from new HIV-suspect patients in Bamako were tested for HIV-1 and HIV-2 using the RDT Determine, followed by ELISA and Western Blot (WB). The Determine test showed a robust diagnostic sensitivity of 98.7% [CI 95: 97.59-99.37] and a diagnostic specificity of 99.2% [CI 95: 98.22-99.67]. The Multispot assay showed a diagnostic sensitivity of 98.77% [CI 95: 97.59-99.37] and a diagnostic specificity of 99.2% [CI 95: 98.22-99.67]. The diagnostic sensitivity and specificity of SD Bioline HIV-1/2 were 100% [CI 95:72.25-100] and 88.89% [CI 95: 56.50- 98.71], respectively. These data indicate excellent performance for HIV RDTs in Mali and we recommend the use of Determine HIV-1/2 for HIV screening and Multispot™ for discriminating HIV-2 from HIV-1 infections.

Abstract Image

Abstract Image

马里检测艾滋病毒感染的三种快速诊断测试的诊断性能。
在马里等资源有限的国家,艾滋病毒感染的诊断主要依靠快速诊断检测(RDTs)。RDT 是专为在护理点 (POC) 使用而设计的诊断检测方法,具有快速、成本效益高和操作简便的特点。然而,在这些国家,尽管艾滋病毒菌株种类繁多,病毒演变迅速,但这些检测方法仍被普遍使用,没有对其性能进行任何初步评估或监测。本研究评估了 2004 年 8 月至 2017 年 11 月期间在马里(HIV-1 和 HIV-2 共存)使用的 HIV RDT(Determine™、Multispot™、SD Bioline™)的可靠性和准确性。使用RDT Determine™对来自巴马科新疑似艾滋病患者的1303份样本进行了HIV-1和HIV-2检测,随后进行了ELISA和Western Blot(WB)检测。Determine™ 检测的诊断灵敏度为 98.7% [CI 95:97.59-99.37],诊断特异性为 99.2% [CI 95:98.22-99.67]。Multispot™ 检测法的诊断灵敏度为 98.77% [CI 95:97.59-99.37],诊断特异性为 99.2% [CI 95:98.22-99.67]。SD Bioline™ HIV-1/2 的诊断灵敏度和特异性分别为 100% [CI 95:72.25-100] 和 88.89% [CI 95:56.50-98.71]。这些数据表明,马里的艾滋病毒快速检测试剂盒性能优异,我们建议使用 Determine™ HIV-1/2 进行艾滋病毒筛查,使用 Multispot™ 区分 HIV-2 和 HIV-1 感染。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信