DeGIR Quality Report 2019: Report on the treatment quality of minimally invasive methods - Interventional therapy (EVAR) of abdominal aortic aneurysms.

IF 1.7
Felix Frenzel, Arno Bücker, Philipp Paprottka, Jonathan Nadjiri, Andreas H Mahnken, Alexander Massmann, Peter Minko, Lothar J Heuser
{"title":"DeGIR Quality Report 2019: Report on the treatment quality of minimally invasive methods - Interventional therapy (EVAR) of abdominal aortic aneurysms.","authors":"Felix Frenzel,&nbsp;Arno Bücker,&nbsp;Philipp Paprottka,&nbsp;Jonathan Nadjiri,&nbsp;Andreas H Mahnken,&nbsp;Alexander Massmann,&nbsp;Peter Minko,&nbsp;Lothar J Heuser","doi":"10.1055/a-1541-8872","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To analyze the quality of endovascular aortic aneurysm repair using the data of the DeGIR quality management system. Comparison of data between 2011 and 2019.</p><p><strong>Materials and methods: </strong>A retrospective analysis of all data registered in the DeGIR quality management system of the year 2019 was performed regarding the treatment quality for endovascular aortic aneurysm repair. Registration of data was voluntary. As quality parameters indication, treatment process data and quality of results were examined. The latter was judged by treatment success, complication rates and radiation exposure.</p><p><strong>Results: </strong>Out of 189 590 data sets overall 1639 cases of EVAR were registered; compared to 2011 this was an increase of 472 cases. 5.9 % of these cases encompassed emergency treatments. The most frequent indication was an abdominal aneurysm with 72 % of cases. In 54 % of cases, the aortic diameter ranged 50-70 mm. The rates for technical success, over all complications and major complications were 92.8 %, 6.7 % and 6.0 % respectively for all EVAR including emergency indications. In general, EVAR yielded a mortality rate of 1.2 % while emergency procedures had a mortality rate of 7.3 %. Median dose area product and fluoroscopy time were 10 503 cGy × cm2 and 20 minutes respectively at a mean procedure time of 114 minutes.</p><p><strong>Conclusion: </strong>Data analysis of the DeGIR quality management system persistently showed a very high technical success rate for endovascular aortic aneurysm repair performed by interventional radiologists accompanied by a low complication rate.</p><p><strong>Key points: </strong>· The voluntary DeGIR quality assurance-system has reached high acceptance among interventional radiologists.. · The database has nearly 200 000 submissions on record for 2019.. · EVAR by interventional radiologists has shown very high technical success as well as a low complication rate..</p><p><strong>Citation format: </strong>· Frenzel F, Bücker A, Paprottka P et al. DeGIR Quality Report 2019: Report on the treatment quality of minimally invasive methods - Interventional therapy (EVAR) of abdominal aortic aneurysms. Fortschr Röntgenstr 2022; 194: 49 - 61.</p>","PeriodicalId":520772,"journal":{"name":"RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin","volume":" ","pages":"49-61"},"PeriodicalIF":1.7000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1055/a-1541-8872","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-1541-8872","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/8/5 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To analyze the quality of endovascular aortic aneurysm repair using the data of the DeGIR quality management system. Comparison of data between 2011 and 2019.

Materials and methods: A retrospective analysis of all data registered in the DeGIR quality management system of the year 2019 was performed regarding the treatment quality for endovascular aortic aneurysm repair. Registration of data was voluntary. As quality parameters indication, treatment process data and quality of results were examined. The latter was judged by treatment success, complication rates and radiation exposure.

Results: Out of 189 590 data sets overall 1639 cases of EVAR were registered; compared to 2011 this was an increase of 472 cases. 5.9 % of these cases encompassed emergency treatments. The most frequent indication was an abdominal aneurysm with 72 % of cases. In 54 % of cases, the aortic diameter ranged 50-70 mm. The rates for technical success, over all complications and major complications were 92.8 %, 6.7 % and 6.0 % respectively for all EVAR including emergency indications. In general, EVAR yielded a mortality rate of 1.2 % while emergency procedures had a mortality rate of 7.3 %. Median dose area product and fluoroscopy time were 10 503 cGy × cm2 and 20 minutes respectively at a mean procedure time of 114 minutes.

Conclusion: Data analysis of the DeGIR quality management system persistently showed a very high technical success rate for endovascular aortic aneurysm repair performed by interventional radiologists accompanied by a low complication rate.

Key points: · The voluntary DeGIR quality assurance-system has reached high acceptance among interventional radiologists.. · The database has nearly 200 000 submissions on record for 2019.. · EVAR by interventional radiologists has shown very high technical success as well as a low complication rate..

Citation format: · Frenzel F, Bücker A, Paprottka P et al. DeGIR Quality Report 2019: Report on the treatment quality of minimally invasive methods - Interventional therapy (EVAR) of abdominal aortic aneurysms. Fortschr Röntgenstr 2022; 194: 49 - 61.

DeGIR质量报告2019:微创方法-介入治疗(EVAR)腹主动脉瘤治疗质量报告。
目的:利用DeGIR质量管理系统的数据分析血管内动脉瘤修复的质量。2011年和2019年的数据比较。材料和方法:回顾性分析2019年DeGIR质量管理体系中关于血管内动脉瘤修复治疗质量的所有数据。数据登记是自愿的。作为质量参数指标,对处理过程数据和结果质量进行了检验。后者是通过治疗成功率、并发症发生率和辐射暴露来判断的。结果:在189 590个数据集中,共登记了1639例EVAR;与2011年相比,增加了472例。这些病例中有5.9%接受了紧急治疗。最常见的适应症是腹部动脉瘤,占72%。在54%的病例中,主动脉直径在50-70毫米之间。包括急诊指征在内的所有EVAR的技术成功率、总并发症和主要并发症分别为92.8%、6.7%和6.0%。一般来说,急诊手术的死亡率为1.2%,而急诊手术的死亡率为7.3%。中位剂量面积积和透视时间分别为10 503 cGy × cm2和20分钟,平均手术时间为114分钟。结论:DeGIR质量管理体系持续数据分析显示,介入放射科医师介入修复血管内动脉瘤的技术成功率非常高,并发症发生率低。·自愿性DeGIR质量保证体系在介入放射科医师中获得了很高的接受度。·该数据库在2019年有近20万份提交记录。·介入放射科医师的EVAR显示出很高的技术成功率和较低的并发症发生率。引文格式:·Frenzel F, b cker a, Paprottka P等。DeGIR质量报告2019:微创方法-介入治疗(EVAR)腹主动脉瘤治疗质量报告。Fortschr Röntgenstr 2022;[194]: 49 - 61。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书