[Biomechanics of mini-implants : analysis of the adverse effects of four clinical situations and proposed resolutions].

Q4 Medicine
Baptiste Turrel, Vanessa Valran, Sarah Gebeile-Chauty
{"title":"[Biomechanics of mini-implants : analysis of the adverse effects of four clinical situations and proposed resolutions].","authors":"Baptiste Turrel,&nbsp;Vanessa Valran,&nbsp;Sarah Gebeile-Chauty","doi":"10.1684/orthodfr.2021.32","DOIUrl":null,"url":null,"abstract":"<p><p>The biomechanical adverse effects generated by our treatments must be considered among the failures of mini-implants, certainly excellent means of anchorage. The aim of this article was to illustrate and comment on mechanical adverse effects and to propose solutions. Four common clinical situations in vestibular technique are analyzed, decomposed three-dimensionally and solved. Maxillary incisor intrusion in direct traction (mini-implant between lateral incisors and canines in direct anchorage) can lead to a disto-labial rotation of the supporting teeth and an incisor flaring. Maxillary incisivo-canine retraction (mini-implant between 5 and 6 in direct anchorage) leads to a canine rotation, a clockwise rotation of the occlusal plane and a version of the adjacent teeth. The maxillary molar two-steps distalization (mini-implant between 5 and 6 with metal ligation to the canine) causes a rotation of the adjacent to the spring teeth, an incisor flaring and a molar disto-version. The protraction of a mandibular molar (mini-implant between 3 and 4 in direct anchorage) causes a disto-labial rotation, a lingual torque and a mesio-version of the molar as well as an incisor flaring and a clockwise rotation of the occlusal plan. The compensation bends on the adjacent teeth, the choice of the location and the type of mini-implant, the use of a power arms to get closer to the center of resistance are among the means of resolution. If mini-implants anchorage allows a significant quantitative effect, adverse effects should be considered individually with a three-dimensional biomechanical analysis.</p>","PeriodicalId":35927,"journal":{"name":"L'' Orthodontie française","volume":"92 2","pages":"195-214"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"L'' Orthodontie française","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1684/orthodfr.2021.32","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 1

Abstract

The biomechanical adverse effects generated by our treatments must be considered among the failures of mini-implants, certainly excellent means of anchorage. The aim of this article was to illustrate and comment on mechanical adverse effects and to propose solutions. Four common clinical situations in vestibular technique are analyzed, decomposed three-dimensionally and solved. Maxillary incisor intrusion in direct traction (mini-implant between lateral incisors and canines in direct anchorage) can lead to a disto-labial rotation of the supporting teeth and an incisor flaring. Maxillary incisivo-canine retraction (mini-implant between 5 and 6 in direct anchorage) leads to a canine rotation, a clockwise rotation of the occlusal plane and a version of the adjacent teeth. The maxillary molar two-steps distalization (mini-implant between 5 and 6 with metal ligation to the canine) causes a rotation of the adjacent to the spring teeth, an incisor flaring and a molar disto-version. The protraction of a mandibular molar (mini-implant between 3 and 4 in direct anchorage) causes a disto-labial rotation, a lingual torque and a mesio-version of the molar as well as an incisor flaring and a clockwise rotation of the occlusal plan. The compensation bends on the adjacent teeth, the choice of the location and the type of mini-implant, the use of a power arms to get closer to the center of resistance are among the means of resolution. If mini-implants anchorage allows a significant quantitative effect, adverse effects should be considered individually with a three-dimensional biomechanical analysis.

[微型植入物的生物力学:四种临床情况的不良反应分析及建议解决方案]。
我们的治疗所产生的生物力学不良反应必须考虑到微型种植体的失败,当然微型种植体是一种优秀的锚固手段。本文的目的是说明和评论机械的不利影响,并提出解决方案。对前庭技术的四种常见临床情况进行了分析,并进行了三维分解和解决。直接牵引中上颌切牙的侵入(侧切牙与直接锚固的犬齿之间的微型种植体)可导致支撑牙的唇侧旋转和切牙的张开。上颌切牙-犬齿内收(直接锚固5 - 6之间的微型种植体)导致犬齿旋转,顺时针旋转咬合平面和相邻牙齿的一个版本。上颌磨牙两步远端(5和6之间的微型种植体与犬齿金属结扎)引起邻近弹簧牙的旋转,门牙外展和磨牙外展。下颌磨牙的拉伸(直接锚固时的3 - 4个微型种植体)引起唇侧旋转、舌侧扭矩和磨牙的中位旋转,以及门牙的扩张和咬合平面的顺时针旋转。在邻牙上补偿弯曲,选择微型种植体的位置和类型,使用动力臂接近阻力中心等都是解决方法。如果微型种植体锚固可以产生显著的定量效应,则应通过三维生物力学分析单独考虑不良影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
L'' Orthodontie française
L'' Orthodontie française Medicine-Medicine (all)
CiteScore
0.30
自引率
0.00%
发文量
23
期刊介绍: L’Orthodontie Française, organe officiel de communication de la Société Française d’Orthopédie Dento-Faciale, est un journal scientifique de référence depuis 1921, de diffusion internationale, indexé à Medline et référencé à l’Index Medicus et à Bibliodent. Le journal a pour vocation d’accueillir les travaux des membres de la SFODF, des conférenciers ayant communiqué lors des congrès de la Société, ou de tout travail soumis à l’approbation de son comité de rédaction, traitant de l’orthopédie dento-faciale ou de tout sujet en rapport avec cette discipline.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信