Lumbar myofascial physical properties in healthy adults: myotonometry vs. shear wave elastography measurements.

IF 1 4区 医学 Q4 RHEUMATOLOGY
Acta reumatologica portuguesa Pub Date : 2021-04-01
Fernando Pimentel-Santos, Santiago Rodrigues Manica, Alfonse T Masi, João Lagoas-Gomes, Mariana Baptista Santos, Sofia Ramiro, Alexandre Sepriano, Kalyani Nair, Patrícia Gomes-Alves, Júlia Costa, Jaime C Branco
{"title":"Lumbar myofascial physical properties in healthy adults: myotonometry vs. shear wave elastography measurements.","authors":"Fernando Pimentel-Santos,&nbsp;Santiago Rodrigues Manica,&nbsp;Alfonse T Masi,&nbsp;João Lagoas-Gomes,&nbsp;Mariana Baptista Santos,&nbsp;Sofia Ramiro,&nbsp;Alexandre Sepriano,&nbsp;Kalyani Nair,&nbsp;Patrícia Gomes-Alves,&nbsp;Júlia Costa,&nbsp;Jaime C Branco","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The human resting myofascial tone maintains the body tone in a neutral posture, the assessment of this and other muscle physical properties (MPP) is relevant, since, it is altered in many pathological states.</p><p><strong>Patients and methods: </strong>Seventeen healthy subjects (8 males), between 18-50 years old, were assessed. The MPP of lower lumbar muscles was evaluated on right and left sides during prone resting position using two devices; myotonometry (stiffness, elasticity and tone) and ultrasound-based shear-wave elastography (SWE) (shear modulus). MTM measurements were performed at two anatomic points (ANp), selected by an experienced reader and at an adjacent ultra-sound determined point (USp). Myotonometry measurements of the erector spinae and SWE measurements of multifidus muscles at the L3-4 level were compared between genders and sides. The intra-reader reliability (IRR) for each device and correlations between techniques were analysed. MTM measurements performed at ANp and USp were compared. The intraclass correlation coefficient (ICC) was assessed for both devices. Correlations between stiffness (myotonometry) and shear modulus (SWE) at the respective muscle depths were assessed with Spearman correlation.</p><p><strong>Results: </strong>Males had greater stiffness and tone than females, particularly on the dominant side. MPP assessed by myotonometry were not different between ANp and USp. Good/Excellent IRR was documented for measurements by MTM (ICC≥0.90) and SWE (ICC≥0.85). No correlation in myotonometry stiffness and SWE shear modulus was found. For myotonometry assessments, the addition of ultrasonography was not different from anatomic localizations. No correlation of measurements was found between devices assessing respective L3-4 level muscles.</p><p><strong>Conclusions: </strong>Gender and side differences must be considered when assessing MPP in axial muscles. For MTM assessments, the addition of ultrasonography was not different to anatomic references. No correlation was found between devices.</p>","PeriodicalId":7229,"journal":{"name":"Acta reumatologica portuguesa","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2021-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta reumatologica portuguesa","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RHEUMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The human resting myofascial tone maintains the body tone in a neutral posture, the assessment of this and other muscle physical properties (MPP) is relevant, since, it is altered in many pathological states.

Patients and methods: Seventeen healthy subjects (8 males), between 18-50 years old, were assessed. The MPP of lower lumbar muscles was evaluated on right and left sides during prone resting position using two devices; myotonometry (stiffness, elasticity and tone) and ultrasound-based shear-wave elastography (SWE) (shear modulus). MTM measurements were performed at two anatomic points (ANp), selected by an experienced reader and at an adjacent ultra-sound determined point (USp). Myotonometry measurements of the erector spinae and SWE measurements of multifidus muscles at the L3-4 level were compared between genders and sides. The intra-reader reliability (IRR) for each device and correlations between techniques were analysed. MTM measurements performed at ANp and USp were compared. The intraclass correlation coefficient (ICC) was assessed for both devices. Correlations between stiffness (myotonometry) and shear modulus (SWE) at the respective muscle depths were assessed with Spearman correlation.

Results: Males had greater stiffness and tone than females, particularly on the dominant side. MPP assessed by myotonometry were not different between ANp and USp. Good/Excellent IRR was documented for measurements by MTM (ICC≥0.90) and SWE (ICC≥0.85). No correlation in myotonometry stiffness and SWE shear modulus was found. For myotonometry assessments, the addition of ultrasonography was not different from anatomic localizations. No correlation of measurements was found between devices assessing respective L3-4 level muscles.

Conclusions: Gender and side differences must be considered when assessing MPP in axial muscles. For MTM assessments, the addition of ultrasonography was not different to anatomic references. No correlation was found between devices.

健康成人腰肌筋膜物理特性:肌张力测量与剪切波弹性成像测量。
目的:人体静息肌筋膜张力维持身体张力处于中性姿势,这和其他肌肉物理特性(MPP)的评估是相关的,因为它在许多病理状态下都发生了改变。患者与方法:17例健康受试者(男性8例),年龄18-50岁。采用两种装置分别评估俯卧位时左右两侧下腰肌的MPP;肌肉测量(刚度、弹性和张力)和基于超声波的剪切波弹性学(SWE)(剪切模量)。MTM测量在两个解剖点(ANp)进行,由经验丰富的读者选择,并在相邻的超声波确定点(USp)进行。在性别和侧面之间比较竖脊肌的肌测测量和L3-4水平多裂肌的SWE测量。分析了每个设备的阅读器内可靠性(IRR)和技术之间的相关性。比较了在ANp和USp下进行的MTM测量。评估两种设备的类内相关系数(ICC)。在各自的肌肉深度刚度(肌张力测量)和剪切模量(SWE)之间的相关性评估Spearman相关。结果:男性比女性有更大的僵硬和张力,特别是在优势侧。ANp与USp的MPP值无明显差异。MTM (ICC≥0.90)和SWE (ICC≥0.85)测量的IRR记录为良/优。肌测刚度与SWE剪切模量无相关性。对于肌张力测量评估,超声检查与解剖定位没有什么不同。在评估各自L3-4水平肌肉的设备之间没有发现测量结果的相关性。结论:在评估轴向肌MPP时,必须考虑性别和侧面差异。对于MTM的评估,超声检查的加入与解剖参考没有什么不同。设备之间没有发现相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta reumatologica portuguesa
Acta reumatologica portuguesa 医学-风湿病学
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊介绍: Acta Reumatólogica Portuguesa is a scientific peer reviewed journal covering all aspects of rheumatic diseases and related to Rheumatology. The journal publishes original articles, reviews, clinical cases, images in rheumatology, letters to the editor and clinical teaching (e.g. guidelines and clinical protocols). Published since 1973, Acta Reumatológica Portuguesa is the official scientific publication of the Portuguese Society of Rheumatology, a non-profit organization that promotes the knowledge and investigation of rheumatic diseases and the development of Rheumatology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信