Wearable Patch Heart Rate Variability Is an Early Marker of Systemic Inflammation During Experimental Human Endotoxemia.

Mats Koeneman, Rebecca Koch, Harry van Goor, Peter Pickkers, Matthijs Kox, Sebastian Bredie
{"title":"Wearable Patch Heart Rate Variability Is an Early Marker of Systemic Inflammation During Experimental Human Endotoxemia.","authors":"Mats Koeneman,&nbsp;Rebecca Koch,&nbsp;Harry van Goor,&nbsp;Peter Pickkers,&nbsp;Matthijs Kox,&nbsp;Sebastian Bredie","doi":"10.1097/SHK.0000000000001827","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Early diagnosis and treatment can reduce the risk of organ failure and mortality in systemic inflammatory conditions. Heart rate variability (HRV) has potential for early identification of the onset of systemic inflammation, as it may detect changes in sympathetic nervous system activity resulting from the developing inflammatory response before clinical signs appear. With the use of new methodologies, we investigated the onset and kinetics of HRV changes as well as several inflammatory parameters and symptoms during experimental human endotoxemia, a model of systemic inflammation in humans in vivo.</p><p><strong>Patients and methods: </strong>Healthy volunteers were intravenously administered LPS (n = 15) or placebo (n = 15). HRV was determined using a wireless wearable device, and parameters low to high frequency (LF:HF) ratio, root mean square of the successive differences (RMSSD), and standard deviation of normal-to-normal R-R intervals (SDNN)were calculated through 1-min-rolling 6-min windows. Plasma cytokine levels and flu-like symptoms and vital signs were serially assessed.</p><p><strong>Results: </strong>The increase in LF:HF ratio, reflecting sympathetic predominance, was more pronounced in the LPS group compared to the placebo group, with the difference becoming statistically significant 65 min following LPS administration (1.63 [1.42-1.83] vs. 1.28 [1.11-1.44], P = 0.005). Significant between-group differences in RMSSD and SDNN were observed from 127 to 140 min post-LPS administration onwards, respectively. Plasma cytokine levels showed significant between-group differences staring 60 min post-LPS. For symptom score, heart rate, temperature, and diastolic blood pressure, significant differences compared with the placebo group were observed at 90, 118, 120, and 124 min post-LPS, respectively.</p><p><strong>Conclusion: </strong>In a controlled human model of systemic inflammation, elevations in the LF:HF ratio followed very shortly after elevations in plasma cytokine levels and preceded onset of flu-like symptoms and alterations in vital signs. HRV may represent a promising non-invasive tool for early detection of a developing systemic inflammatory response.</p>","PeriodicalId":238832,"journal":{"name":"Shock (Augusta, Ga.)","volume":" ","pages":"537-543"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Shock (Augusta, Ga.)","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/SHK.0000000000001827","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Introduction: Early diagnosis and treatment can reduce the risk of organ failure and mortality in systemic inflammatory conditions. Heart rate variability (HRV) has potential for early identification of the onset of systemic inflammation, as it may detect changes in sympathetic nervous system activity resulting from the developing inflammatory response before clinical signs appear. With the use of new methodologies, we investigated the onset and kinetics of HRV changes as well as several inflammatory parameters and symptoms during experimental human endotoxemia, a model of systemic inflammation in humans in vivo.

Patients and methods: Healthy volunteers were intravenously administered LPS (n = 15) or placebo (n = 15). HRV was determined using a wireless wearable device, and parameters low to high frequency (LF:HF) ratio, root mean square of the successive differences (RMSSD), and standard deviation of normal-to-normal R-R intervals (SDNN)were calculated through 1-min-rolling 6-min windows. Plasma cytokine levels and flu-like symptoms and vital signs were serially assessed.

Results: The increase in LF:HF ratio, reflecting sympathetic predominance, was more pronounced in the LPS group compared to the placebo group, with the difference becoming statistically significant 65 min following LPS administration (1.63 [1.42-1.83] vs. 1.28 [1.11-1.44], P = 0.005). Significant between-group differences in RMSSD and SDNN were observed from 127 to 140 min post-LPS administration onwards, respectively. Plasma cytokine levels showed significant between-group differences staring 60 min post-LPS. For symptom score, heart rate, temperature, and diastolic blood pressure, significant differences compared with the placebo group were observed at 90, 118, 120, and 124 min post-LPS, respectively.

Conclusion: In a controlled human model of systemic inflammation, elevations in the LF:HF ratio followed very shortly after elevations in plasma cytokine levels and preceded onset of flu-like symptoms and alterations in vital signs. HRV may represent a promising non-invasive tool for early detection of a developing systemic inflammatory response.

可穿戴贴片心率变异性是实验性人类内毒素血症期间全身性炎症的早期标志。
简介:早期诊断和治疗可以降低全身性炎症的器官衰竭和死亡率。心率变异性(HRV)具有早期识别全身性炎症发作的潜力,因为它可以在临床症状出现之前检测到由炎症反应引起的交感神经系统活动的变化。通过使用新的方法,我们研究了实验人类内毒素血症(一种人体体内全身性炎症模型)期间HRV变化的发生和动力学以及几种炎症参数和症状。患者和方法:健康志愿者静脉注射LPS (n = 15)或安慰剂(n = 15)。采用无线可穿戴设备测定HRV,通过1 min滚动6 min窗口计算低高频(LF:HF)比、连续差均方根(RMSSD)和正态R-R区间标准差(SDNN)等参数。连续评估血浆细胞因子水平和流感样症状及生命体征。结果:与安慰剂组相比,LPS组LF:HF比值的升高更为明显,反映交感优势,且LPS给药65 min后差异具有统计学意义(1.63[1.42-1.83]比1.28 [1.11-1.44],P = 0.005)。lps给药后127 - 140分钟,RMSSD和SDNN组间差异显著。血浆细胞因子水平在lps后60分钟开始出现显著差异。在症状评分、心率、体温和舒张压方面,分别在lps后90、118、120和124分钟观察到与安慰剂组相比有显著差异。结论:在受控的人类全身性炎症模型中,血浆细胞因子水平升高后不久,LF:HF比值升高,并先于流感样症状和生命体征的改变出现。HRV可能是一种有前途的非侵入性工具,用于早期发现正在发生的全身炎症反应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书