Decision support system through automatic algorithms and electronic request in diagnosis of anaemia for primary care patients.

IF 3.8 3区 医学 Q1 MEDICAL LABORATORY TECHNOLOGY
Biochemia Medica Pub Date : 2021-06-15 Epub Date: 2021-04-15 DOI:10.11613/BM.2021.020702
Enrique Rodriguez-Borja, Adela Pozo-Giraldez, Macarena Díaz-Gimenez, Ausias Hervas-Romero, Africa Corchon-Peyrallo, Inmaculada Vinyals-Bellido, Arturo Carratala Calvo
{"title":"Decision support system through automatic algorithms and electronic request in diagnosis of anaemia for primary care patients.","authors":"Enrique Rodriguez-Borja,&nbsp;Adela Pozo-Giraldez,&nbsp;Macarena Díaz-Gimenez,&nbsp;Ausias Hervas-Romero,&nbsp;Africa Corchon-Peyrallo,&nbsp;Inmaculada Vinyals-Bellido,&nbsp;Arturo Carratala Calvo","doi":"10.11613/BM.2021.020702","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>An appropriate management of anaemia laboratory tests is crucial for a correct diagnosis and treatment. A non-sequential \"shotgun\" approach (where every anaemia related test is ordered) causes workload and cost increases and could be potentially harmful. We have implemented a Decision Support System through our laboratory information system (LIMS) based on reflexive algorithms and automatic generation of interpretative reports specifically in diagnosis of anaemia for primary care patients.</p><p><strong>Materials and methods: </strong>When a request contained an \"Anaemia Suspicion Study\" profile, more than twenty automatic reflexive rules were activated in our LIMS based upon laboratory results. These rules normally involved the addition of reflexive tests. A final report was automatically generated for each interpretation which was always reviewed for their validity by two staff pathologists. We measured the impact of this system in the ordering of most common anaemia related tests and if a proper treatment was established based on the interpretive report.</p><p><strong>Results: </strong>From all the studies performed, only 12% were positive being \"iron deficiency\" and \"anaemia of chronic disease\" the most frequent causes, 62% and 17%, respectively. Proper treatment was established in 88% of these anaemic patients. Total iron, transferrin, ferritin, folate and vitamin B12 demand decreased substantially after implementation representing a cost reduction of 40% only for these five tests.</p><p><strong>Conclusions: </strong>Our system has easily improved patient outcomes, advising on individual clinical cases. We have also noticeably reduced the number of over-requested tests and laboratory costs.</p>","PeriodicalId":9021,"journal":{"name":"Biochemia Medica","volume":"31 2","pages":"020702"},"PeriodicalIF":3.8000,"publicationDate":"2021-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8047786/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biochemia Medica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11613/BM.2021.020702","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/4/15 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: An appropriate management of anaemia laboratory tests is crucial for a correct diagnosis and treatment. A non-sequential "shotgun" approach (where every anaemia related test is ordered) causes workload and cost increases and could be potentially harmful. We have implemented a Decision Support System through our laboratory information system (LIMS) based on reflexive algorithms and automatic generation of interpretative reports specifically in diagnosis of anaemia for primary care patients.

Materials and methods: When a request contained an "Anaemia Suspicion Study" profile, more than twenty automatic reflexive rules were activated in our LIMS based upon laboratory results. These rules normally involved the addition of reflexive tests. A final report was automatically generated for each interpretation which was always reviewed for their validity by two staff pathologists. We measured the impact of this system in the ordering of most common anaemia related tests and if a proper treatment was established based on the interpretive report.

Results: From all the studies performed, only 12% were positive being "iron deficiency" and "anaemia of chronic disease" the most frequent causes, 62% and 17%, respectively. Proper treatment was established in 88% of these anaemic patients. Total iron, transferrin, ferritin, folate and vitamin B12 demand decreased substantially after implementation representing a cost reduction of 40% only for these five tests.

Conclusions: Our system has easily improved patient outcomes, advising on individual clinical cases. We have also noticeably reduced the number of over-requested tests and laboratory costs.

通过自动算法和电子请求的决策支持系统对初级保健患者进行贫血诊断。
导读:贫血实验室检查的适当管理是正确诊断和治疗的关键。非顺序的“散弹枪”方法(将所有与贫血相关的测试都按顺序进行)会导致工作量和成本增加,并且可能有害。我们通过我们的实验室信息系统(LIMS)实现了一个决策支持系统,该系统基于反射算法和自动生成解释性报告,专门用于初级保健患者的贫血诊断。材料和方法:当一个请求包含“贫血怀疑研究”的简介时,我们的LIMS根据实验室结果激活了20多条自动反射规则。这些规则通常包括附加的反身性测试。每次解释都会自动生成一份最终报告,并由两名工作人员病理学家审查其有效性。我们测量了该系统对大多数常见贫血相关测试排序的影响,以及是否根据解释性报告建立了适当的治疗方法。结果:在所有进行的研究中,只有12%呈阳性,其中“缺铁”和“慢性病贫血”是最常见的原因,分别为62%和17%。88%的贫血患者得到了适当的治疗。实施后,对总铁、转铁蛋白、铁蛋白、叶酸和维生素B12的需求大幅下降,仅这五种检测的成本就降低了40%。结论:我们的系统很容易改善患者的治疗效果,对个别临床病例提出建议。我们还显著减少了要求过多的检测次数和实验室费用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biochemia Medica
Biochemia Medica 医学-医学实验技术
CiteScore
5.50
自引率
3.00%
发文量
70
审稿时长
>12 weeks
期刊介绍: Biochemia Medica is the official peer-reviewed journal of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Journal provides a wide coverage of research in all aspects of clinical chemistry and laboratory medicine. Following categories fit into the scope of the Journal: general clinical chemistry, haematology and haemostasis, molecular diagnostics and endocrinology. Development, validation and verification of analytical techniques and methods applicable to clinical chemistry and laboratory medicine are welcome as well as studies dealing with laboratory organization, automation and quality control. Journal publishes on a regular basis educative preanalytical case reports (Preanalytical mysteries), articles dealing with applied biostatistics (Lessons in biostatistics) and research integrity (Research integrity corner).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信