{"title":"A New Parameter, the Smallest Oblique Sagittal Area of the Neural Foramen, as an Index to Diagnose Cervical Neural Foramen Stenosis.","authors":"Yukun Jia, Zhan Peng, Jin Li, Guangye Wang","doi":"10.1177/08465371211005540","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The objective was to reconstruct the cervical neural foramen and accurately measure the minimum oblique sagittal area of the neural foramen. Then, a quantitative diagnostic standard for cervical neural foramen stenosis was proposed and its value as an indication for surgery was evaluated.</p><p><strong>Methods: </strong>(1) CT data were used to reconstruct the neural foramen using Mimics software, and the minimum area was measured. (2) The optimal cut-off value was determined using a receiver operating characteristic (ROC) curve. (3) Patients who underwent single-segment surgery were divided into 2 groups according to the cut-off value. Then the postoperative neurological function improvement rate was analyzed to identify any significant difference between the 2 groups.</p><p><strong>Results: </strong>A total of 1056 neural foramens were measured in 132 patients, of which 495 (46.88%) were diagnosed as radiculopathy by clinical neurological examination. The optimal cut-off value determined by the ROC curve was 25.95 mm<sup>2</sup> (sensitivity 74.1%, specificity 80.9%) and the area under the curve (AUC) was 0.827 (95%CI: 0.803-0.849). There was a significant difference in the neurological function improvement rate between the 2 groups after surgery (<i>P</i> < 0.05). The intraclass correlation coefficient (ICC) was 0.969.</p><p><strong>Conclusion: </strong>Three-dimensional digital simulation reconstruction of CT data is a good measurement method. The optimal cut-off value determined here not only has a certain reference value for the diagnosis of cervical neural foramen bony stenosis, but also helps to select patients suitable for neural foramen decompression and can be used as a reference for surgical indication.</p>","PeriodicalId":444006,"journal":{"name":"Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes","volume":" ","pages":"170-178"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/08465371211005540","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/08465371211005540","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/4/19 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Objective: The objective was to reconstruct the cervical neural foramen and accurately measure the minimum oblique sagittal area of the neural foramen. Then, a quantitative diagnostic standard for cervical neural foramen stenosis was proposed and its value as an indication for surgery was evaluated.
Methods: (1) CT data were used to reconstruct the neural foramen using Mimics software, and the minimum area was measured. (2) The optimal cut-off value was determined using a receiver operating characteristic (ROC) curve. (3) Patients who underwent single-segment surgery were divided into 2 groups according to the cut-off value. Then the postoperative neurological function improvement rate was analyzed to identify any significant difference between the 2 groups.
Results: A total of 1056 neural foramens were measured in 132 patients, of which 495 (46.88%) were diagnosed as radiculopathy by clinical neurological examination. The optimal cut-off value determined by the ROC curve was 25.95 mm2 (sensitivity 74.1%, specificity 80.9%) and the area under the curve (AUC) was 0.827 (95%CI: 0.803-0.849). There was a significant difference in the neurological function improvement rate between the 2 groups after surgery (P < 0.05). The intraclass correlation coefficient (ICC) was 0.969.
Conclusion: Three-dimensional digital simulation reconstruction of CT data is a good measurement method. The optimal cut-off value determined here not only has a certain reference value for the diagnosis of cervical neural foramen bony stenosis, but also helps to select patients suitable for neural foramen decompression and can be used as a reference for surgical indication.