Carolina Rodrigues, Rui Cerejo, Rui Rodrigues, Eugénia Pinto, José Fragata
{"title":"Right Ventricular Outflow Tract Pseudo Aneurysm After Reconstruction With Small Intestinal Submucosal Cormatrix Patch A Word Of Caution.","authors":"Carolina Rodrigues, Rui Cerejo, Rui Rodrigues, Eugénia Pinto, José Fragata","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Tetralogy of Fallot is very prevalent with correction techniques well standardized. Whenever infundibular incisions are needed, patch reconstruction seems mandatory. Recently, the small intestinal submucosal (CorMatrix, MAC's Medical Group,) patch was introduced, with optimal results in pre-clinical studies. However, clinical results do not match its pre-clinical promises, particularly when used in right ventricular outflow tract and pulmonary artery reconstructions. We describe a case of Tetralogy of Fallot for which small intestinal submucosal (CorMatrix) patch was used as a trans-annular patch, with development of a massive pseudo-aneurysm.</p>","PeriodicalId":87136,"journal":{"name":"Revista portuguesa de cirurgia cardio-toracica e vascular : orgao oficial da Sociedade Portuguesa de Cirurgia Cardio-Toracica e Vascular","volume":"27 2","pages":"117-119"},"PeriodicalIF":0.0000,"publicationDate":"2020-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista portuguesa de cirurgia cardio-toracica e vascular : orgao oficial da Sociedade Portuguesa de Cirurgia Cardio-Toracica e Vascular","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Tetralogy of Fallot is very prevalent with correction techniques well standardized. Whenever infundibular incisions are needed, patch reconstruction seems mandatory. Recently, the small intestinal submucosal (CorMatrix, MAC's Medical Group,) patch was introduced, with optimal results in pre-clinical studies. However, clinical results do not match its pre-clinical promises, particularly when used in right ventricular outflow tract and pulmonary artery reconstructions. We describe a case of Tetralogy of Fallot for which small intestinal submucosal (CorMatrix) patch was used as a trans-annular patch, with development of a massive pseudo-aneurysm.
法洛四联症非常普遍,校正技术很标准化。每当需要进行漏斗切口时,补片重建似乎是强制性的。最近,小肠粘膜下贴片(CorMatrix, MAC's Medical Group,)被引入,在临床前研究中取得了最佳效果。然而,临床结果并不符合临床前的承诺,特别是当用于右心室流出道和肺动脉重建时。我们描述了一例法洛四联症,小肠粘膜下(CorMatrix)贴片被用作跨环贴片,发展为巨大的假性动脉瘤。