Domenico Baldi, Jacopo Colombo, Simone Verardi, Alberto Rebaudi, Federico Rebaudi, Christian Makary
{"title":"Clinical osseointegration of bone level implants with conical shape and textured surface with low primary stability.","authors":"Domenico Baldi, Jacopo Colombo, Simone Verardi, Alberto Rebaudi, Federico Rebaudi, Christian Makary","doi":"10.23736/S0026-4970.20.04277-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Evidence shows lower chance for osseointegration of implants without sufficient primary stability. The present retrospective study observed bone level conical screw implants with textured surface without primary stability.</p><p><strong>Methods: </strong>Twenty-six Stark conical screw implants, with V-Blast (Vanish Blast) surface treatment were placed with low primary stability, (insertion torque lower than 10 N/cm and visible mobility at lateral load of 250 g). A soft diet was prescribed. osseointegration was assessed applying 30 Ncm of reverse torque 6 months after placement.</p><p><strong>Results: </strong>The 26 implants that did not achieve primary stability still had a survival rate of 96% after the observation period and were classified as successful according with ICOI Pisa consensus conference success, survival, failure classification .96% of the implants showed clinical osteointegration and were successfully restored. After 12 months, all implants remained functional.</p><p><strong>Conclusions: </strong>It can be concluded that bone-level implants with V-Blast surface in absence of functional loading are able to achieve osteointegration, even with low primary stability.</p>","PeriodicalId":18742,"journal":{"name":"Minerva stomatologica","volume":"69 1","pages":"8-13"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minerva stomatologica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23736/S0026-4970.20.04277-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2
Abstract
Background: Evidence shows lower chance for osseointegration of implants without sufficient primary stability. The present retrospective study observed bone level conical screw implants with textured surface without primary stability.
Methods: Twenty-six Stark conical screw implants, with V-Blast (Vanish Blast) surface treatment were placed with low primary stability, (insertion torque lower than 10 N/cm and visible mobility at lateral load of 250 g). A soft diet was prescribed. osseointegration was assessed applying 30 Ncm of reverse torque 6 months after placement.
Results: The 26 implants that did not achieve primary stability still had a survival rate of 96% after the observation period and were classified as successful according with ICOI Pisa consensus conference success, survival, failure classification .96% of the implants showed clinical osteointegration and were successfully restored. After 12 months, all implants remained functional.
Conclusions: It can be concluded that bone-level implants with V-Blast surface in absence of functional loading are able to achieve osteointegration, even with low primary stability.
期刊介绍:
The journal Minerva Stomatologica publishes scientific papers on dentistry and maxillo-facial surgery. Manuscripts may be submitted in the form of editorials, original articles, review articles, case reports, therapeutical notes, special articles and letters to the Editor. Manuscripts are expected to comply with the instructions to authors which conform to the Uniform Requirements for Manuscripts Submitted to Biomedical Editors by the International Committee of Medical Journal Editors (www.icmje.org). Articles not conforming to international standards will not be considered for acceptance.