Oscillator Strengths for Lines of Ionized Uranium (U II).

Charles H Corliss
{"title":"Oscillator Strengths for Lines of Ionized Uranium (U II).","authors":"Charles H Corliss","doi":"10.6028/jres.080A.045","DOIUrl":null,"url":null,"abstract":"<p><p>Oscillator strengths for 49 lines of U II recently measured by Voight can be used to calibrate the intensity scale of the U II lines in the NBS Tables of Spectral-Line Intensities and derive a larger set of oscillator strengths of lower precision but consistent with the new measurements. The standard deviation of the differences between the two sets of <i>gf</i>-values for the 49 lines is 29 percent. Oscillator strengths of that precision are given for 776 additional lines from the NBS Intensity Tables. The uncertainty in absolute value is 67 percent.</p>","PeriodicalId":17018,"journal":{"name":"Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry","volume":"80A 3","pages":"429-438"},"PeriodicalIF":0.0000,"publicationDate":"1976-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5293350/pdf/","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Research of the National Bureau of Standards. Section A, Physics and Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6028/jres.080A.045","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"1976/6/1 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

Abstract

Oscillator strengths for 49 lines of U II recently measured by Voight can be used to calibrate the intensity scale of the U II lines in the NBS Tables of Spectral-Line Intensities and derive a larger set of oscillator strengths of lower precision but consistent with the new measurements. The standard deviation of the differences between the two sets of gf-values for the 49 lines is 29 percent. Oscillator strengths of that precision are given for 776 additional lines from the NBS Intensity Tables. The uncertainty in absolute value is 67 percent.

Abstract Image

Abstract Image

电离铀(uii)谱线的振子强度。
Voight最近测量的49条U II线的振荡强度可用于校准NBS谱线强度表中的U II线的强度尺度,并得出精度较低但与新测量结果一致的更大的振荡强度集。49条线的两组gf值之差的标准差为29%。从NBS强度表中给出了776条额外线的振荡器强度。绝对值的不确定度是67%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信