Different modes of diode laser irradiation: effects on enamel surface and intrapulpal temperature at debonding.

Q2 Medicine
Soghra Yassaei, Hosseinagha Aghili, Zahra Ebrahimi-Nik
{"title":"Different modes of diode laser irradiation: effects on enamel surface and intrapulpal temperature at debonding.","authors":"Soghra Yassaei,&nbsp;Hosseinagha Aghili,&nbsp;Zahra Ebrahimi-Nik","doi":"10.5978/islsm.27_18-OR-20","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>laser aided debonding of ceramic brackets has been proved to be effective in reducing enamel surface damages, though the optimal parameters of laser to be chose is in question. The aim of this study was to investigate the six different regimens of diode laser irradiation on enamel surface characteristics and intrapulpal temperature changes while debonding.</p><p><strong>Materials and methods: </strong>90 polycrystalline brackets were bonded to 90 intact extracted premolars. At debonding, teeth were divided into 6 groups (n = 15) and were subjected to the following regimen of diode laser irradiation; G1 = 2 W, continuous wave, G2 = 2.5 W, continuous wave, G3 = 3 W, continuous wave, G4 = 2 W, pulsed mode, G5 = 2.5 W, pulsed mode, G6 = 3 W, pulsed mode. After debonding, the adhesive remnant index, the lengths and frequency of enamel cracks were compared among the groups. 5 teeth out of 15 were randomly selected from each group to assess the intrapulpal temperature changes.</p><p><strong>Results: </strong>The number of enamel cracks increased significantly in all the specimens after debonding. Enamel crack length increased significantly in all the study groups except G3 and G6. The increase in intrapulpal temperature was significantly below the benchmark of 5.5 C for all the specimens. Significant difference was observed in adhesive remnant index scores among the groups and more than half of the teeth showed a score of 2.</p><p><strong>Conclusion: </strong>Diode-laser irradiation in pulsed mode or continuous wave at given outputs (2, 2.5, 3 W) were not statistically different in regard to producing enamel surface damages or increasing intrapulpal temperature.</p>","PeriodicalId":17981,"journal":{"name":"Laser therapy","volume":"27 3","pages":"214-218"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5978/islsm.27_18-OR-20","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laser therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5978/islsm.27_18-OR-20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 3

Abstract

Background: laser aided debonding of ceramic brackets has been proved to be effective in reducing enamel surface damages, though the optimal parameters of laser to be chose is in question. The aim of this study was to investigate the six different regimens of diode laser irradiation on enamel surface characteristics and intrapulpal temperature changes while debonding.

Materials and methods: 90 polycrystalline brackets were bonded to 90 intact extracted premolars. At debonding, teeth were divided into 6 groups (n = 15) and were subjected to the following regimen of diode laser irradiation; G1 = 2 W, continuous wave, G2 = 2.5 W, continuous wave, G3 = 3 W, continuous wave, G4 = 2 W, pulsed mode, G5 = 2.5 W, pulsed mode, G6 = 3 W, pulsed mode. After debonding, the adhesive remnant index, the lengths and frequency of enamel cracks were compared among the groups. 5 teeth out of 15 were randomly selected from each group to assess the intrapulpal temperature changes.

Results: The number of enamel cracks increased significantly in all the specimens after debonding. Enamel crack length increased significantly in all the study groups except G3 and G6. The increase in intrapulpal temperature was significantly below the benchmark of 5.5 C for all the specimens. Significant difference was observed in adhesive remnant index scores among the groups and more than half of the teeth showed a score of 2.

Conclusion: Diode-laser irradiation in pulsed mode or continuous wave at given outputs (2, 2.5, 3 W) were not statistically different in regard to producing enamel surface damages or increasing intrapulpal temperature.

不同二极管激光照射方式对脱粘牙釉质表面及牙髓内温度的影响。
背景:激光辅助陶瓷托槽脱粘术已被证明能有效减少牙釉质表面损伤,但激光的最佳选择参数尚不明确。本研究的目的是探讨六种不同的二极管激光照射方案对牙釉质表面特征和脱粘时牙髓内温度的变化。材料和方法:将90个多晶托槽粘接在90个完整的拔牙前磨牙上。在脱粘时,将牙齿分为6组(n = 15),进行以下方案的二极管激光照射;G1 = 2w,连续波,G2 = 2.5 W,连续波,G3 = 3w,连续波,G4 = 2w,脉冲模式,G5 = 2.5 W,脉冲模式,G6 = 3w,脉冲模式。比较脱粘后各组牙釉质残粘指数、牙釉质裂纹长度和出现频率。每组15颗牙中随机抽取5颗评估牙髓内温度变化。结果:所有标本脱粘后牙釉质裂纹数量均明显增加。除G3、G6组外,其余各组牙釉质裂纹长度均显著增加。所有标本的髓内温度升高幅度均明显低于5.5℃的基准值。两组间粘接剂残留指数得分差异有统计学意义,超过半数牙的粘接剂残留指数得分为2分。结论:脉冲激光照射与连续激光照射(2、2.5、3w)对牙釉质表面损伤及牙髓内温度升高的影响无统计学差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Laser therapy
Laser therapy Medicine-Surgery
CiteScore
2.80
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信