{"title":"Prosthetic solution for fixed full-arch maxillary prosthesis with implant divergent parallelism greater than 45°. A case report.","authors":"Gustavo Frainer Barbosa, Daniele Pereira Dotto","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A non-ideal implant position and angulation may bring about some technical concerns because the abutment prosthetic possibilities may fail to correct the implant angulation or its consequent prosthetic restoration insertion plane. This case report describes a prosthetic solution for fixed full-arch maxillary prosthesis with six implants (Bone-Level Regular CrossFit®, Straumann AG, Basel, Switzerland) non-satisfactory position in maxilla; one of the implants showed buccal angulation and a divergent parallelism greater than 45° in relation to the other five implants. To correct the implant angulation and the insertion bar plane, a screw-retained RC non-engaging gold abutment for bridge was used in five out of six implants, and a combination of a screw-retained RC CrossFit™ gold abutment for crown and a Screw Bloc System (CNG Soluções Protéticas, São Paulo, Brazil) was used for the right-hand-side anterior implant that showed a greater buccal implant angulation (>45°). A satisfactory outcome was obtained, which totally met the patient's expectations. Hence, the case was successfully solved with the avoidance of buccal insertion of the prosthetic screw and the consequent esthetic appearance loss of the fixed full-arch prosthesis.</p>","PeriodicalId":35508,"journal":{"name":"Stomatologija","volume":"21 2","pages":"62-64"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Stomatologija","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
Abstract
A non-ideal implant position and angulation may bring about some technical concerns because the abutment prosthetic possibilities may fail to correct the implant angulation or its consequent prosthetic restoration insertion plane. This case report describes a prosthetic solution for fixed full-arch maxillary prosthesis with six implants (Bone-Level Regular CrossFit®, Straumann AG, Basel, Switzerland) non-satisfactory position in maxilla; one of the implants showed buccal angulation and a divergent parallelism greater than 45° in relation to the other five implants. To correct the implant angulation and the insertion bar plane, a screw-retained RC non-engaging gold abutment for bridge was used in five out of six implants, and a combination of a screw-retained RC CrossFit™ gold abutment for crown and a Screw Bloc System (CNG Soluções Protéticas, São Paulo, Brazil) was used for the right-hand-side anterior implant that showed a greater buccal implant angulation (>45°). A satisfactory outcome was obtained, which totally met the patient's expectations. Hence, the case was successfully solved with the avoidance of buccal insertion of the prosthetic screw and the consequent esthetic appearance loss of the fixed full-arch prosthesis.
不理想的种植体位置和角度可能会带来一些技术问题,因为基台假体可能无法纠正种植体角度或随之而来的假体修复插入平面。本病例报告描述了一种固定全弓上颌假体的修复方案,该假体采用六个种植体(Bone-Level Regular CrossFit®,Straumann AG, Basel, Switzerland)在上颌不满意的位置;其中一个种植体显示颊角和发散平行度大于45°相对于其他五个种植体。为了矫正种植体的角度和插入杆平面,6个种植体中有5个使用了螺钉保留的RC无接合金基台用于桥,并且在右侧前牙种植体中使用了螺钉保留的RC CrossFit™金基台用于冠和螺钉块系统(CNG Soluções protticas, s o Paulo, Brazil)的组合,显示出更大的颊种植体角度(>45°)。结果令人满意,完全达到了患者的预期。因此,该病例成功解决,避免了假体螺钉的颊部插入,并避免了固定全弓假体的美观损失。