Primary stability of self-tapping dual etched implants.

Q3 Medicine
Zethy H Kassim, Nor D Nor Hisham, Nur A Dardiri, Khor Goot Heah, Izyan Hazwani Baharuddin, Nicola De Angelis
{"title":"Primary stability of self-tapping dual etched implants.","authors":"Zethy H Kassim,&nbsp;Nor D Nor Hisham,&nbsp;Nur A Dardiri,&nbsp;Khor Goot Heah,&nbsp;Izyan Hazwani Baharuddin,&nbsp;Nicola De Angelis","doi":"10.23736/S0026-4970.19.04242-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The aims of this study were to enumerate the primary implant stability quotient (ISQ) value of self-tapping dual etched implants and to explore the influence of parameters such as implant length, implant diameter, age, gender, implant location and osteotomy preparation on the ISQ value.</p><p><strong>Methods: </strong>Retrospective data from clinical worksheets given to participants during two implant courses held between the periods of 2013 to 2014 were evaluated. A total of 61 implants were considered based on the inclusion criteria. The effects of parameters such as implant diameter, implant length, age, gender, implant location and osteotomy protocol on ISQ values were analyzed.</p><p><strong>Results: </strong>Mean ISQ value for all implants was 67.21±9.13. Age of patients (P=0.016) and location of implants (P=0.041) had a significant linear relationship with the ISQ values. Within the age limit of the patients in this study, it was found that an increase in one year of patient's age results in 0.20 decrease in ISQ value (95% CI: -0.36, -0.04). However, placing an implant in the posterior maxilla may negatively affect the ISQ with a likely decrease in primary stability by 6.76 ISQ value (95% CI: -13.22, -0.30).</p><p><strong>Conclusions: </strong>The results suggest that the mean ISQ achieved by the participants were comparable with the range reported for this particular type of implants. The patient's age and location of implants were elucidated as the determinant factors of primary implant stability.</p>","PeriodicalId":18742,"journal":{"name":"Minerva stomatologica","volume":"68 6","pages":"291-296"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minerva stomatologica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23736/S0026-4970.19.04242-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The aims of this study were to enumerate the primary implant stability quotient (ISQ) value of self-tapping dual etched implants and to explore the influence of parameters such as implant length, implant diameter, age, gender, implant location and osteotomy preparation on the ISQ value.

Methods: Retrospective data from clinical worksheets given to participants during two implant courses held between the periods of 2013 to 2014 were evaluated. A total of 61 implants were considered based on the inclusion criteria. The effects of parameters such as implant diameter, implant length, age, gender, implant location and osteotomy protocol on ISQ values were analyzed.

Results: Mean ISQ value for all implants was 67.21±9.13. Age of patients (P=0.016) and location of implants (P=0.041) had a significant linear relationship with the ISQ values. Within the age limit of the patients in this study, it was found that an increase in one year of patient's age results in 0.20 decrease in ISQ value (95% CI: -0.36, -0.04). However, placing an implant in the posterior maxilla may negatively affect the ISQ with a likely decrease in primary stability by 6.76 ISQ value (95% CI: -13.22, -0.30).

Conclusions: The results suggest that the mean ISQ achieved by the participants were comparable with the range reported for this particular type of implants. The patient's age and location of implants were elucidated as the determinant factors of primary implant stability.

自攻双蚀刻植入物的初步稳定性。
背景:本研究的目的是枚举自攻双蚀刻种植体的一段种植体稳定商(ISQ)值,并探讨种植体长度、种植体直径、年龄、性别、种植体位置和截骨准备等参数对ISQ值的影响。方法:回顾性分析2013年至2014年期间两次种植课程参与者的临床工作表数据。根据纳入标准,共考虑61个种植体。分析种植体直径、种植体长度、年龄、性别、种植体位置、截骨方式等参数对ISQ值的影响。结果:种植体的平均ISQ值为67.21±9.13。患者年龄(P=0.016)和种植体位置(P=0.041)与ISQ值有显著的线性关系。在本研究患者的年龄限制范围内,发现患者年龄每增加一岁,ISQ值降低0.20 (95% CI: -0.36, -0.04)。然而,在后上颌骨放置种植体可能会对ISQ产生负面影响,可能会使初级稳定性降低6.76 ISQ值(95% CI: -13.22, -0.30)。结论:结果表明,参与者获得的平均ISQ与报道的这种特定类型植入物的范围相当。患者的年龄和种植体的位置被阐明为初级种植体稳定性的决定因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Minerva stomatologica
Minerva stomatologica DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.50
自引率
0.00%
发文量
0
期刊介绍: The journal Minerva Stomatologica publishes scientific papers on dentistry and maxillo-facial surgery. Manuscripts may be submitted in the form of editorials, original articles, review articles, case reports, therapeutical notes, special articles and letters to the Editor. Manuscripts are expected to comply with the instructions to authors which conform to the Uniform Requirements for Manuscripts Submitted to Biomedical Editors by the International Committee of Medical Journal Editors (www.icmje.org). Articles not conforming to international standards will not be considered for acceptance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信