Influence of Solvent Composition and Surface Tension on the Signal Intensity of Amino Acids in Electrospray Ionization Mass Spectrometry.

Q3 Physics and Astronomy
Mass spectrometry Pub Date : 2019-01-01 Epub Date: 2019-11-30 DOI:10.5702/massspectrometry.A0077
Ami Kageyama Kaneshima, Akira Motoyama, Mitsuo Takayama
{"title":"Influence of Solvent Composition and Surface Tension on the Signal Intensity of Amino Acids in Electrospray Ionization Mass Spectrometry.","authors":"Ami Kageyama Kaneshima,&nbsp;Akira Motoyama,&nbsp;Mitsuo Takayama","doi":"10.5702/massspectrometry.A0077","DOIUrl":null,"url":null,"abstract":"<p><p>The influence of solvent composition and surface tension on the signal intensity of deprotonated molecules [M-H]<sup>-</sup> in electrospray ionization mass spectrometry (ESI MS) was evaluated using alanine (Ala), threonine (Thr) and phenylalanine (Phe), which have differing levels of hydrophobicity. The surface tension of the ESI solution was varied by changing the ratio of the organic solvents methanol (MeOH) and acetonitrile (MeCN) in water (H<sub>2</sub>O). In ESI MS, the signal intensity of all the amino acids was increased with decreasing surface tension for the two solutions, H<sub>2</sub>O/MeOH and H<sub>2</sub>O/MeCN. The use of H<sub>2</sub>O/MeCN was more favorable for achieving a strong signal for the analytes compared to H<sub>2</sub>O/MeOH. The smaller vaporization enthalpy of MeCN compared to MeOH was proposed as one of the most plausible explanation for this. The order of the signal intensity of amino acids was Phe>Thr>Ala, the same order as their hydrophobicity. It can be practically concluded that the use of solutions with lower surface tensions and lower vaporization enthalpies would result in higher signal intensities in ESI MS.</p>","PeriodicalId":18243,"journal":{"name":"Mass spectrometry","volume":"8 1","pages":"A0077"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5702/massspectrometry.A0077","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mass spectrometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5702/massspectrometry.A0077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/11/30 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Physics and Astronomy","Score":null,"Total":0}
引用次数: 5

Abstract

The influence of solvent composition and surface tension on the signal intensity of deprotonated molecules [M-H]- in electrospray ionization mass spectrometry (ESI MS) was evaluated using alanine (Ala), threonine (Thr) and phenylalanine (Phe), which have differing levels of hydrophobicity. The surface tension of the ESI solution was varied by changing the ratio of the organic solvents methanol (MeOH) and acetonitrile (MeCN) in water (H2O). In ESI MS, the signal intensity of all the amino acids was increased with decreasing surface tension for the two solutions, H2O/MeOH and H2O/MeCN. The use of H2O/MeCN was more favorable for achieving a strong signal for the analytes compared to H2O/MeOH. The smaller vaporization enthalpy of MeCN compared to MeOH was proposed as one of the most plausible explanation for this. The order of the signal intensity of amino acids was Phe>Thr>Ala, the same order as their hydrophobicity. It can be practically concluded that the use of solutions with lower surface tensions and lower vaporization enthalpies would result in higher signal intensities in ESI MS.

Abstract Image

Abstract Image

Abstract Image

溶剂组成和表面张力对电喷雾质谱分析中氨基酸信号强度的影响。
采用不同疏水性的丙氨酸(Ala)、苏氨酸(Thr)和苯丙氨酸(Phe),研究了溶剂组成和表面张力对电喷雾电离质谱(ESI MS)中去质子化分子[M-H]-信号强度的影响。通过改变有机溶剂甲醇(MeOH)和乙腈(MeCN)在水中的比例,改变ESI溶液的表面张力。在ESI质谱中,随着H2O/MeOH和H2O/MeCN两种溶液表面张力的降低,所有氨基酸的信号强度都增加。与H2O/MeOH相比,H2O/MeCN更有利于获得强信号。与MeOH相比,men的蒸发焓更小,这是最合理的解释之一。氨基酸的信号强度顺序为丙氨酸>苏氨酸>丙氨酸,与其疏水性顺序相同。实际上可以得出结论,在ESI MS中,使用低表面张力和低汽化焓的溶液会产生更高的信号强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Mass spectrometry
Mass spectrometry Physics and Astronomy-Instrumentation
CiteScore
1.90
自引率
0.00%
发文量
3
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信