The effectiveness of home-use photobiomodulation toothbrush for treating dentin hypersensitivity: A pilot study.

Q2 Medicine
Maziar Mir, Seyed Masoud Mojahedi, Jan Tunér, Masoud Shabani, Fatemeh Darabi, Alireza Rohban
{"title":"The effectiveness of home-use photobiomodulation toothbrush for treating dentin hypersensitivity: A pilot study.","authors":"Maziar Mir,&nbsp;Seyed Masoud Mojahedi,&nbsp;Jan Tunér,&nbsp;Masoud Shabani,&nbsp;Fatemeh Darabi,&nbsp;Alireza Rohban","doi":"10.5978/islsm.28_19-OR-16","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>Dentin hypersensitivity is a frequent oral condition among patients suffering from gingival recession. Recent studies have suggested that photobiomodulation has the potential to reduce inflammation and relieve pain. The present study aims to assess the effectiveness of a new design of photobiomodulation toothbrush with specific irradiation parameters as a homecare device in treating dentin hypersensitivity and to compare its therapeutic effect with that of fluoride varnish.</p><p><strong>Materials and methods: </strong>Thirty patients with gingival recession and dentin hypersensitivity were selected and randomly assigned to three groups of equal size: fluoride varnish, photobiomodulation, and the combination. Dentin pain and hypersensitivity were measured using visual analog scale (VAS) by two distinct tests: the contact test with a periodontal probe and the air blast test on the areas of gingival recession and denuded root; once at baseline and again one month after the initial application of treatments. Laser irradiation was carried out at the wavelength of 660 nm in CW with an output power of 40 mW for 30 seconds per spot (1.2 J per spot, 6 J/cm<sup>2</sup> energy density, and 200 mW/cm<sup>2</sup> power density), perpendicularly to denuded root surfaces in non-contact mode.</p><p><strong>Results: </strong>A significant reduction in dentin pain and hypersensitivity was observed in all three groups. However, the reduction was significantly greater in the combination group.</p><p><strong>Conclusion: </strong>At-home treatment of dentin hypersensitivity with photobiomodulation toothbrush is a convenient, safe, and effective method for the management of dentin hypersensitivity.</p>","PeriodicalId":17981,"journal":{"name":"Laser therapy","volume":"28 3","pages":"193-198"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6923343/pdf/islsm-28-193.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laser therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5978/islsm.28_19-OR-16","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 1

Abstract

Background and aims: Dentin hypersensitivity is a frequent oral condition among patients suffering from gingival recession. Recent studies have suggested that photobiomodulation has the potential to reduce inflammation and relieve pain. The present study aims to assess the effectiveness of a new design of photobiomodulation toothbrush with specific irradiation parameters as a homecare device in treating dentin hypersensitivity and to compare its therapeutic effect with that of fluoride varnish.

Materials and methods: Thirty patients with gingival recession and dentin hypersensitivity were selected and randomly assigned to three groups of equal size: fluoride varnish, photobiomodulation, and the combination. Dentin pain and hypersensitivity were measured using visual analog scale (VAS) by two distinct tests: the contact test with a periodontal probe and the air blast test on the areas of gingival recession and denuded root; once at baseline and again one month after the initial application of treatments. Laser irradiation was carried out at the wavelength of 660 nm in CW with an output power of 40 mW for 30 seconds per spot (1.2 J per spot, 6 J/cm2 energy density, and 200 mW/cm2 power density), perpendicularly to denuded root surfaces in non-contact mode.

Results: A significant reduction in dentin pain and hypersensitivity was observed in all three groups. However, the reduction was significantly greater in the combination group.

Conclusion: At-home treatment of dentin hypersensitivity with photobiomodulation toothbrush is a convenient, safe, and effective method for the management of dentin hypersensitivity.

家用光生物调节牙刷治疗牙本质过敏的有效性:一项初步研究。
背景与目的:牙本质过敏是牙龈萎缩患者常见的口腔疾病。最近的研究表明,光生物调节具有减少炎症和缓解疼痛的潜力。本研究旨在评估一种具有特定辐照参数的光生物调节牙刷作为家庭护理装置治疗牙本质过敏的效果,并将其与氟化物清漆的治疗效果进行比较。材料和方法:选择30例牙龈萎缩和牙本质过敏患者,随机分为三组,大小相同:氟化物清漆组、光生物调节剂组和联合组。采用视觉模拟量表(visual analogue scale, VAS)对牙本质疼痛和超敏反应进行测量,采用牙周探针接触试验和龈退缩区和脱牙根区空气爆破试验两种不同的试验方法;一次是在基线,一次是在治疗开始一个月后。激光照射波长为660 nm,输出功率为40 mW,每光斑照射30秒(1.2 J/光斑,6 J/cm2能量密度,200 mW/cm2功率密度),垂直于剥落的根表面,以非接触方式照射。结果:三组患者牙本质疼痛和过敏症状均明显减轻。然而,联合用药组的降幅明显更大。结论:光生物调节牙刷在家中治疗牙本质过敏是一种方便、安全、有效的治疗牙本质过敏的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Laser therapy
Laser therapy Medicine-Surgery
CiteScore
2.80
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信