The Dependence of Water Heater Energy Factor on Deviations from Nominal Conditions.

ASHRAE transactions Pub Date : 2017-01-01
William M Healy
{"title":"The Dependence of Water Heater Energy Factor on Deviations from Nominal Conditions.","authors":"William M Healy","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>An analytical study is carried out to assess the impact of corrections to nominal test conditions on the measured energy factor for residential water heaters. While test conditions are specified in the method of test, the difficulty in exactly achieiving these test conditions in the laboratory necessitates a computational approach to correct the results to nominal conditions. This paper examines the magnitude of those corrections for a range of water heaters of various fuel type, heating method, and size across a number of potential draw volumes during a 24 hour simulated use test. In making these corrections, a recovery efficiency and a standby heat loss coefficient are determined during the test; the effects of variations in those measured values on the resultant energy factor are discussed. Finally, the impact of tighter test tolerances on the variability of the energy factor is investigated to assist in evaluating the benefits of changing test conditions.</p>","PeriodicalId":91206,"journal":{"name":"ASHRAE transactions","volume":"123 Pt 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6506833/pdf/nihms923338.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASHRAE transactions","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An analytical study is carried out to assess the impact of corrections to nominal test conditions on the measured energy factor for residential water heaters. While test conditions are specified in the method of test, the difficulty in exactly achieiving these test conditions in the laboratory necessitates a computational approach to correct the results to nominal conditions. This paper examines the magnitude of those corrections for a range of water heaters of various fuel type, heating method, and size across a number of potential draw volumes during a 24 hour simulated use test. In making these corrections, a recovery efficiency and a standby heat loss coefficient are determined during the test; the effects of variations in those measured values on the resultant energy factor are discussed. Finally, the impact of tighter test tolerances on the variability of the energy factor is investigated to assist in evaluating the benefits of changing test conditions.

Abstract Image

Abstract Image

Abstract Image

热水器能量因数与标称工况偏差的关系。
进行了一项分析研究,以评估对标称测试条件的修正对住宅热水器测量能量因子的影响。虽然测试方法中规定了测试条件,但在实验室中精确达到这些测试条件的困难需要采用计算方法将结果修正为标称条件。本文考察了在24小时模拟使用测试中,各种燃料类型、加热方法和尺寸的热水器的修正幅度。在进行这些修正时,在测试期间确定了回收效率和备用热损失系数;讨论了这些测量值的变化对所得能量因子的影响。最后,研究了更严格的测试公差对能量因子变异性的影响,以帮助评估改变测试条件的好处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信