A retrospective study comparing the ultrathin versus conventional bronchoscope for performing radial endobronchial ultrasound in the evaluation of peripheral pulmonary lesions.
{"title":"A retrospective study comparing the ultrathin versus conventional bronchoscope for performing radial endobronchial ultrasound in the evaluation of peripheral pulmonary lesions.","authors":"Inderpaul Singh Sehgal, Sahajal Dhooria, Amanjit Bal, Nalini Gupta, Babu Ram, Ashutosh N Aggarwal, Ritesh Agarwal","doi":"10.4103/lungindia.lungindia_115_18","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Few studies have reported on the utility of ultrathin bronchoscopes (UTBs) for performing radial probe endobronchial ultrasound (EBUS). Herein, we describe our experience with UTB and conventional bronchoscope (CB) for performing radial EBUS.</p><p><strong>Materials and methods: </strong>This was a retrospective study comparing the diagnostic yield of a prototype UTB (external diameter 3 mm, working channel diameter 1.7 mm) versus CBs (external diameter ≥4.9 mm) in performing radial EBUS for the evaluation of peripheral pulmonary lesions (PPLs). Fluoroscopic guidance was not available.</p><p><strong>Results: </strong>A total of 121 subjects (34, UTB; 87, CB; 69.4% males) with a mean (standard deviation [SD]) age of 55.2 (14.8) years underwent radial EBUS. The mean (SD) size of PPLs on computed tomography of the thorax was 22.2 (13.7) mm. The lesions were significantly smaller in the UTB group (16.4 vs 24.7 mm, P = 0.006). Eight lesions could be visualized within the lumen of the peripheral smaller bronchi with the UTB. The overall yield of radial EBUS was 52.9% and was similar in the two groups (UTB vs. CB, 55.9% vs. 51.7%; P = 0.7). The procedure time was significantly shorter in the UTB group. On multivariate logistic regression, the yield was similar in the two groups after adjusting for the size and location of the lesion and position of the radial probe in relation to the lesion.</p><p><strong>Conclusion: </strong>Despite smaller lesions, radial EBUS performed with the UTB was found to have similar efficacy to that performed with the CB. More lesions could be visualized endobronchially using the UTB making it an attractive alternative for performing radial EBUS.</p>","PeriodicalId":520705,"journal":{"name":"Lung India : official organ of Indian Chest Society","volume":" ","pages":"102-107"},"PeriodicalIF":1.2000,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/5f/2a/LI-36-102.PMC6410583.pdf","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lung India : official organ of Indian Chest Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/lungindia.lungindia_115_18","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
Abstract
Background: Few studies have reported on the utility of ultrathin bronchoscopes (UTBs) for performing radial probe endobronchial ultrasound (EBUS). Herein, we describe our experience with UTB and conventional bronchoscope (CB) for performing radial EBUS.
Materials and methods: This was a retrospective study comparing the diagnostic yield of a prototype UTB (external diameter 3 mm, working channel diameter 1.7 mm) versus CBs (external diameter ≥4.9 mm) in performing radial EBUS for the evaluation of peripheral pulmonary lesions (PPLs). Fluoroscopic guidance was not available.
Results: A total of 121 subjects (34, UTB; 87, CB; 69.4% males) with a mean (standard deviation [SD]) age of 55.2 (14.8) years underwent radial EBUS. The mean (SD) size of PPLs on computed tomography of the thorax was 22.2 (13.7) mm. The lesions were significantly smaller in the UTB group (16.4 vs 24.7 mm, P = 0.006). Eight lesions could be visualized within the lumen of the peripheral smaller bronchi with the UTB. The overall yield of radial EBUS was 52.9% and was similar in the two groups (UTB vs. CB, 55.9% vs. 51.7%; P = 0.7). The procedure time was significantly shorter in the UTB group. On multivariate logistic regression, the yield was similar in the two groups after adjusting for the size and location of the lesion and position of the radial probe in relation to the lesion.
Conclusion: Despite smaller lesions, radial EBUS performed with the UTB was found to have similar efficacy to that performed with the CB. More lesions could be visualized endobronchially using the UTB making it an attractive alternative for performing radial EBUS.
背景:很少有研究报道超薄支气管镜(UTBs)用于桡骨探头支气管超声(EBUS)的应用。在此,我们描述了我们使用UTB和传统支气管镜(CB)进行桡骨EBUS的经验。材料和方法:这是一项回顾性研究,比较了原型UTB(外径3mm,工作通道直径1.7 mm)和CBs(外径≥4.9 mm)在桡骨EBUS中评估周围性肺病变(ppl)的诊断率。没有透视指导。结果:共121例受试者(34例,UTB;87年,CB;69.4%男性),平均(标准差[SD])年龄为55.2(14.8)岁,行桡骨EBUS。胸部计算机断层扫描显示PPLs的平均(SD)大小为22.2 (13.7)mm, UTB组的病变明显较小(16.4 vs 24.7 mm, P = 0.006)。UTB在周围小支气管管腔内可见8个病灶。放射状EBUS总产率为52.9%,两组相似(UTB vs. CB, 55.9% vs. 51.7%;P = 0.7)。UTB组手术时间明显缩短。在多元逻辑回归中,在调整病变的大小和位置以及桡骨探头相对于病变的位置后,两组的产量相似。结论:尽管病灶较小,但采用UTB进行桡骨EBUS的疗效与采用CB相似。使用UTB可以在支气管内看到更多病变,使其成为桡骨EBUS的一个有吸引力的选择。