M Andreasi Bassi, S Lico, C Andrisani, Z Ormanier, F Carinci
{"title":"Diffusion of light through quartz fiber-reinforced epoxy resin double taper posts.","authors":"M Andreasi Bassi, S Lico, C Andrisani, Z Ormanier, F Carinci","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to evaluate the progression of the light through a series of translucent posts available on the market (D.T. Light-post, R.T.D.).</p><p><strong>Materials & methods: </strong>nine D.T. Light-posts (DTLPs) were analyzed, 3 for each available measure. Each post was trans-illuminated both in vertical trans-ilumination (VTI) and oblique trans-illumination (OTI), via a light curing unit (LCU) (V.I.P., Bisco), in complete darkness conditions, and the resulting image of the post, was digitally acquired with a 1:1 ratio. The images were then analyzed using digital image analysis software (Image Pro plus 4.1, Media Cybernetics) previously performing the light intensity calibration, of the LCU, by means a radiometer (Curing Radiometer model 100, Demetron Corp.). The evaluation of the progression of the light through the posts was conducted for each post along its longitudinal axis.</p><p><strong>Results: </strong>no significant differences concerning VTI vs OTI for DTLP n.1 (p = 0.341) and DTLP n. 3 (p = 0.115), while for DTLP n.2 a significant difference was observed (p = 0.041); Conclusion: The results demonstrate that the greater the section of the post, the greater its ability to transmit light at a distance; also the vertical Trans-illumination of the post is to be preferred to the oblique one.</p>","PeriodicalId":82453,"journal":{"name":"Refu'at ha-peh veha-shinayim (1993)","volume":"34 1","pages":"6-12, 70"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Refu'at ha-peh veha-shinayim (1993)","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: The aim of this study was to evaluate the progression of the light through a series of translucent posts available on the market (D.T. Light-post, R.T.D.).
Materials & methods: nine D.T. Light-posts (DTLPs) were analyzed, 3 for each available measure. Each post was trans-illuminated both in vertical trans-ilumination (VTI) and oblique trans-illumination (OTI), via a light curing unit (LCU) (V.I.P., Bisco), in complete darkness conditions, and the resulting image of the post, was digitally acquired with a 1:1 ratio. The images were then analyzed using digital image analysis software (Image Pro plus 4.1, Media Cybernetics) previously performing the light intensity calibration, of the LCU, by means a radiometer (Curing Radiometer model 100, Demetron Corp.). The evaluation of the progression of the light through the posts was conducted for each post along its longitudinal axis.
Results: no significant differences concerning VTI vs OTI for DTLP n.1 (p = 0.341) and DTLP n. 3 (p = 0.115), while for DTLP n.2 a significant difference was observed (p = 0.041); Conclusion: The results demonstrate that the greater the section of the post, the greater its ability to transmit light at a distance; also the vertical Trans-illumination of the post is to be preferred to the oblique one.