Evaluation of NU-FlexSIV Socket Performance for Military Service Members with Transfemoral Amputation.

U.S. Army Medical Department journal Pub Date : 2018-07-01
Starr E Brown, Elizabeth Russell Esposito, Andrea J Ikeda, Jason M Wilken, Stefania Fatone
{"title":"Evaluation of NU-FlexSIV Socket Performance for Military Service Members with Transfemoral Amputation.","authors":"Starr E Brown,&nbsp;Elizabeth Russell Esposito,&nbsp;Andrea J Ikeda,&nbsp;Jason M Wilken,&nbsp;Stefania Fatone","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Ischial containment sockets are the current standard of care for military service members with transfemoral amputation. However, they fit intimately with the ischium, which may limit hip motion and contribute to proximal socket discomfort, a common complaint among prosthesis users. Subischial sockets, such as the newly described Northwestern University Flexible Subischial Vacuum (NU-FlexSIV) Socket technique, do not interact with the ischium, potentially increasing hip motion and improving comfort.</p><p><strong>Purpose: </strong>To transfer the NU-FlexSIV Socket technique to military prosthetists and evaluate performance among military service members with transfemoral amputation.</p><p><strong>Study design: </strong>case series.</p><p><strong>Methods: </strong>Four of the 11 enrolled subjects completed the study protocol comparing the NU-FlexSIV Socket to the ischial containment socket. Gait kinematics (over ground and on stairs), physical performance measures (Four-Square Step Test, T-test of Agility, and an obstacle course), limb-socket motion, and socket comfort were assessed after accommodation time in each socket.</p><p><strong>Results: </strong>While wearing the NU-FlexSIV Socket, sagittal plane hip motion generally increased while coronal plane trunk motion and walking speed remained largely unaffected during over ground walking. During stair ascent, sagittal plane hip motion increased while wearing the NU-FlexSIV Socket, with minimal changes in walking speed for all subjects. Pre- and post-walking fluoroscopy measures suggest fit of the NU-FlexSIV Socket was less affected by activity. Most subjects reported that the NU-FlexSIV Socket was more comfortable for sitting but some found it less comfortable for walking and running. Performance measure results were mixed. Although attempts were made to consistently implement the NU-FlexSIV Socket technique, some challenges were experienced.</p><p><strong>Conclusions: </strong>The NU-FlexSIV Socket provided greater hip motion across a variety of tasks without adversely affecting other movement mechanics but did not consistently improve socket comfort. Variability in the liners and socket materials used may have contributed to variability in results. Overall, the design was a viable alternative to traditional ischial containment sockets for some individuals with transfemoral amputation.</p>","PeriodicalId":88789,"journal":{"name":"U.S. Army Medical Department journal","volume":" 2-18","pages":"38-47"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"U.S. Army Medical Department journal","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Ischial containment sockets are the current standard of care for military service members with transfemoral amputation. However, they fit intimately with the ischium, which may limit hip motion and contribute to proximal socket discomfort, a common complaint among prosthesis users. Subischial sockets, such as the newly described Northwestern University Flexible Subischial Vacuum (NU-FlexSIV) Socket technique, do not interact with the ischium, potentially increasing hip motion and improving comfort.

Purpose: To transfer the NU-FlexSIV Socket technique to military prosthetists and evaluate performance among military service members with transfemoral amputation.

Study design: case series.

Methods: Four of the 11 enrolled subjects completed the study protocol comparing the NU-FlexSIV Socket to the ischial containment socket. Gait kinematics (over ground and on stairs), physical performance measures (Four-Square Step Test, T-test of Agility, and an obstacle course), limb-socket motion, and socket comfort were assessed after accommodation time in each socket.

Results: While wearing the NU-FlexSIV Socket, sagittal plane hip motion generally increased while coronal plane trunk motion and walking speed remained largely unaffected during over ground walking. During stair ascent, sagittal plane hip motion increased while wearing the NU-FlexSIV Socket, with minimal changes in walking speed for all subjects. Pre- and post-walking fluoroscopy measures suggest fit of the NU-FlexSIV Socket was less affected by activity. Most subjects reported that the NU-FlexSIV Socket was more comfortable for sitting but some found it less comfortable for walking and running. Performance measure results were mixed. Although attempts were made to consistently implement the NU-FlexSIV Socket technique, some challenges were experienced.

Conclusions: The NU-FlexSIV Socket provided greater hip motion across a variety of tasks without adversely affecting other movement mechanics but did not consistently improve socket comfort. Variability in the liners and socket materials used may have contributed to variability in results. Overall, the design was a viable alternative to traditional ischial containment sockets for some individuals with transfemoral amputation.

经股骨截肢军人NU-FlexSIV套接器性能评价。
坐骨收容套是目前的标准护理军人与经股截肢。然而,它们与坐骨非常贴合,这可能会限制髋关节的活动,并导致近端窝不适,这是假体使用者常见的抱怨。坐骨下窝,如西北大学新近描述的柔性坐骨下真空(NU-FlexSIV)坐骨窝技术,不与坐骨相互作用,潜在地增加髋关节运动和改善舒适度。目的:将NU-FlexSIV套接技术应用于军事义肢,并评价其在经股骨截肢军人中的应用效果。研究设计:病例系列。方法:11名入组受试者中有4名完成了比较NU-FlexSIV套接器与坐骨收容套接器的研究方案。步态运动学(在地面上和楼梯上)、物理性能测量(四方步测试、敏捷性t检验和障碍训练)、肢体-窝运动和窝舒适在每个窝的适应时间后进行评估。结果:当佩戴NU-FlexSIV Socket时,在地上行走时,矢状面髋关节运动普遍增加,而冠状面躯干运动和行走速度基本未受影响。在上楼梯过程中,佩戴NU-FlexSIV套接器后,所有受试者的髋关节矢状面运动增加,行走速度变化最小。行走前和行走后的透视检查显示NU-FlexSIV插槽的配合度受活动的影响较小。大多数受试者报告说,NU-FlexSIV插座坐着更舒服,但有些人发现它在走路和跑步时不太舒服。绩效评估结果喜忧参半。虽然尝试一致地实现NU-FlexSIV插座技术,但遇到了一些挑战。结论:NU-FlexSIV关节套在各种任务中提供了更大的髋关节运动,而不会对其他运动力学产生不利影响,但并没有持续改善关节套的舒适度。所使用的衬垫和套筒材料的可变性可能导致结果的可变性。总的来说,对于一些经股截肢患者,该设计是传统坐骨包容套的可行替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信