Multiple Stent Delivery System "Multi-LOC": Focal self-expanding nitinol stenting of complex femoropopliteal lesions-A monocenter feasibility pilot study.

IF 1.4 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
JRSM Cardiovascular Disease Pub Date : 2019-01-03 eCollection Date: 2019-01-01 DOI:10.1177/2048004018822618
Martin Sigl, Johannes Jung, Heinz Kölble, Klaus Amendt
{"title":"Multiple Stent Delivery System \"Multi-LOC\": Focal self-expanding nitinol stenting of complex femoropopliteal lesions-A monocenter feasibility pilot study.","authors":"Martin Sigl,&nbsp;Johannes Jung,&nbsp;Heinz Kölble,&nbsp;Klaus Amendt","doi":"10.1177/2048004018822618","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>The Multiple Stent Delivery System (VascuFlex® Multi-LOC) is a novel stent delivery system with six short stents (13 mm long each) mounted on one wire-guided catheter, designed for the treatment of femoropopliteal arteries. The aim of the present study is to evaluate the safety and the feasibility of the VascuFlex® \"Multi-LOC\" stent delivery system, which enables spot stenting without changing the delivery system.</p><p><strong>Methods and results: </strong>After proof of concept in a porcine model and after <i><i>European Conformity</i></i> marking, first clinical experiences were gathered in 20 patients with severe intermittent claudication or critical limb ischemia. First-in-human data are presented. The study included 20 limbs that underwent femoropopliteal revascularization for claudication (n = 14) or critical limb ischemia (n = 6). \"Multi-LOC\" provisional spot stenting resulted in acute technical success in all lesions with resolution of flow-limiting dissection and elastic recoil after balloon dilatation of the femoropopliteal artery. There were no device-related complications. Follow-up examinations after 30 to 40 days revealed no major adverse events, and six months' results were encouraging.</p><p><strong>Conclusions: </strong>First clinical use of the novel Multiple Stent Delivery System (Multi-LOC) after balloon dilatation of the femoropopliteal artery was safe and feasible in this early study.</p>","PeriodicalId":30457,"journal":{"name":"JRSM Cardiovascular Disease","volume":"8 ","pages":"2048004018822618"},"PeriodicalIF":1.4000,"publicationDate":"2019-01-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/2048004018822618","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JRSM Cardiovascular Disease","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/2048004018822618","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 2

Abstract

Aims: The Multiple Stent Delivery System (VascuFlex® Multi-LOC) is a novel stent delivery system with six short stents (13 mm long each) mounted on one wire-guided catheter, designed for the treatment of femoropopliteal arteries. The aim of the present study is to evaluate the safety and the feasibility of the VascuFlex® "Multi-LOC" stent delivery system, which enables spot stenting without changing the delivery system.

Methods and results: After proof of concept in a porcine model and after European Conformity marking, first clinical experiences were gathered in 20 patients with severe intermittent claudication or critical limb ischemia. First-in-human data are presented. The study included 20 limbs that underwent femoropopliteal revascularization for claudication (n = 14) or critical limb ischemia (n = 6). "Multi-LOC" provisional spot stenting resulted in acute technical success in all lesions with resolution of flow-limiting dissection and elastic recoil after balloon dilatation of the femoropopliteal artery. There were no device-related complications. Follow-up examinations after 30 to 40 days revealed no major adverse events, and six months' results were encouraging.

Conclusions: First clinical use of the novel Multiple Stent Delivery System (Multi-LOC) after balloon dilatation of the femoropopliteal artery was safe and feasible in this early study.

Abstract Image

Abstract Image

Abstract Image

多支架输送系统“Multi-LOC”:复杂股腘病变的局部自膨胀镍钛合金支架置入-单中心可行性试点研究。
目的:多支架输送系统(VascuFlex®Multi-LOC)是一种新型支架输送系统,6个短支架(每个13毫米长)安装在一根导线引导导管上,设计用于治疗股腘动脉。本研究的目的是评估VascuFlex®“Multi-LOC”支架输送系统的安全性和可行性,该系统可以在不改变输送系统的情况下进行定点支架植入。方法和结果:在猪模型中验证概念并获得欧洲符合性标志后,收集了20例严重间歇性跛行或严重肢体缺血患者的首次临床经验。提出了首次人体试验数据。该研究包括20例因跛行或严重肢体缺血而行股腘血管重建术的肢体(n = 14)或危重肢体(n = 6)。“多loc”临时点支架术在所有病变中均取得了技术上的成功,并解决了股腘动脉球囊扩张后的受限夹层和弹性后坐力问题。无器械相关并发症。30 ~ 40天后的随访检查未发现重大不良事件,6个月的结果令人鼓舞。结论:在这项早期研究中,新型多支架输送系统(Multi-LOC)在股腘动脉球囊扩张后首次临床应用是安全可行的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
JRSM Cardiovascular Disease
JRSM Cardiovascular Disease CARDIAC & CARDIOVASCULAR SYSTEMS-
自引率
6.20%
发文量
12
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信