{"title":"CT-guided procedures: an initial experience.","authors":"Andrei Roman,&nbsp;Patriciu Achimas-Cadariu,&nbsp;Bogdan Fetica,&nbsp;Vlad Gata,&nbsp;Andrada Seicean","doi":"10.15386/cjmed-1145","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>Despite their usefulness, CT-guided procedures have a low profile in Romania. The current study has the purpose of describing a first experience in performing these procedures.</p><p><strong>Methods: </strong>Tumors and fluid collections that were inaccessible for biopsy or drainage by ultrasound or endoscopic guidance were included. The procedures were performed using a 64-slice GE Optima CT660 CT scanner. The biopsies were carried out using the coaxial technique with an 18 G semiautomatic needle. The drainages were performed using 10 F pig-tail drains that were inserted using the Seldinger technique. Data regarding the size and location of the target lesion, puncture technique, success and complication rates were recorded.</p><p><strong>Results: </strong>Between May 2017 and April 2018, 30 procedures were performed, of which 26 biopsies and 4 drainage insertions. Of the biopsies 3 were mediastinal, 8 pulmonary, 6 retroperitoneal, 4 pelvic, and 5 of the bone. The drainages were performed for pelvic lymphoceles. The average lesion size was 3.2 cm (0.7-9 cm), with a depth from the skin of 9.1 cm (0.6-15.2 cm). The average procedure duration was 58 minutes (31-93 minutes). A conclusive histopathological diagnosis was set after 92.3% of biopsies. Three procedures resulted in complications, two being minor (hemothorax, soft tissue hematoma) and one severe (tension pneumothorax requiring drainage).</p><p><strong>Conclusions: </strong>CT guidance offers safe access to lesions that cannot be biopsied or drained under ultrasound or endoscopic guidance.</p>","PeriodicalId":91233,"journal":{"name":"Clujul medical (1957)","volume":"91 4","pages":"427-434"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/64/8b/cm-91-427.PMC6296730.pdf","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clujul medical (1957)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15386/cjmed-1145","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/10/30 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Background and aims: Despite their usefulness, CT-guided procedures have a low profile in Romania. The current study has the purpose of describing a first experience in performing these procedures.

Methods: Tumors and fluid collections that were inaccessible for biopsy or drainage by ultrasound or endoscopic guidance were included. The procedures were performed using a 64-slice GE Optima CT660 CT scanner. The biopsies were carried out using the coaxial technique with an 18 G semiautomatic needle. The drainages were performed using 10 F pig-tail drains that were inserted using the Seldinger technique. Data regarding the size and location of the target lesion, puncture technique, success and complication rates were recorded.

Results: Between May 2017 and April 2018, 30 procedures were performed, of which 26 biopsies and 4 drainage insertions. Of the biopsies 3 were mediastinal, 8 pulmonary, 6 retroperitoneal, 4 pelvic, and 5 of the bone. The drainages were performed for pelvic lymphoceles. The average lesion size was 3.2 cm (0.7-9 cm), with a depth from the skin of 9.1 cm (0.6-15.2 cm). The average procedure duration was 58 minutes (31-93 minutes). A conclusive histopathological diagnosis was set after 92.3% of biopsies. Three procedures resulted in complications, two being minor (hemothorax, soft tissue hematoma) and one severe (tension pneumothorax requiring drainage).

Conclusions: CT guidance offers safe access to lesions that cannot be biopsied or drained under ultrasound or endoscopic guidance.

Abstract Image

Abstract Image

Abstract Image

ct引导手术:初步经验。
背景和目的:尽管ct引导的手术很有用,但在罗马尼亚却很低调。当前研究的目的是描述执行这些程序的第一次经验。方法:包括超声或内镜引导下无法进行活检或引流的肿瘤和积液。手术采用64层GE Optima CT660 CT扫描仪。活检采用同轴技术,采用18g半自动针。采用Seldinger技术插入10f猪尾引流管进行引流。记录目标病灶的大小和位置、穿刺技术、成功率和并发症发生率等数据。结果:2017年5月至2018年4月,共进行30例手术,其中活检26例,引流插入4例。纵隔活检3例,肺活检8例,腹膜后活检6例,盆腔活检4例,骨活检5例。盆腔淋巴囊肿行引流术。病灶平均大小为3.2 cm (0.7 ~ 9 cm),距皮肤深度为9.1 cm (0.6 ~ 15.2 cm)。平均手术时间为58分钟(31-93分钟)。92.3%的活组织检查后确定结论性组织病理学诊断。三个手术导致并发症,两个是轻微的(血胸,软组织血肿)和一个严重的(张力性气胸需要引流)。结论:CT引导为超声或内窥镜引导下无法活检或引流的病变提供了安全的通道。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信