Thermal Changes of Root Surface of Anterior Primary Teeth in Pulpectomy with Er:YAG Laser.

Zahra Bahrololoomi, Reza Birang, Nasim Chiniforush, Hazhir Yousefshahi, Elnaz Foroughi
{"title":"Thermal Changes of Root Surface of Anterior Primary Teeth in Pulpectomy with Er:YAG Laser.","authors":"Zahra Bahrololoomi,&nbsp;Reza Birang,&nbsp;Nasim Chiniforush,&nbsp;Hazhir Yousefshahi,&nbsp;Elnaz Foroughi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Successful root treatment depends on elimination of microorganisms from the root canal. Considering incomplete removal of bacteria from the canal by usual methods, lasers have been suggested as a new modality. Despite their anti-bacterial properties, lasers can cause thermal changes. This study assessed the thermal changes of root surface in pulpectomy of primary teeth following the use of Er:YAG laser.</p><p><strong>Materials and methods: </strong>Sixty primary anterior teeth were collected and prepared by K-file up to number 50. Then, they were randomly divided into two groups and were irradiated with Er:YAG laser. The first group was irradiated with 1 W laser and the second group with 1.5 W laser. The laser irradiation time was two 10-second cycles with a 2-second interval in both groups. Thermal changes were measured by a thermometer in the apical and coronal areas per second. The results were analyzed by repeated measures ANOVA considering the laser power as between-subject variable.</p><p><strong>Results: </strong>There was a temperature increase in the coronal and apical areas in use of 1 W power. There was a temperature rise in the coronal and apical areas in use of 1.5 W power. The temperature rise in the apical third was more than that in the coronal third; also, the average temperature rise was more in use of 1.5 W power than 1 W power.</p><p><strong>Conclusions: </strong>As the average temperature increase was not more than 7°C in any group, this type of laser seems to be suitable for root treatment of primary anterior teeth.</p>","PeriodicalId":30286,"journal":{"name":"Journal of Dentistry of Tehran University of Medical Sciences","volume":"15 3","pages":"178-186"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6079182/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dentistry of Tehran University of Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Successful root treatment depends on elimination of microorganisms from the root canal. Considering incomplete removal of bacteria from the canal by usual methods, lasers have been suggested as a new modality. Despite their anti-bacterial properties, lasers can cause thermal changes. This study assessed the thermal changes of root surface in pulpectomy of primary teeth following the use of Er:YAG laser.

Materials and methods: Sixty primary anterior teeth were collected and prepared by K-file up to number 50. Then, they were randomly divided into two groups and were irradiated with Er:YAG laser. The first group was irradiated with 1 W laser and the second group with 1.5 W laser. The laser irradiation time was two 10-second cycles with a 2-second interval in both groups. Thermal changes were measured by a thermometer in the apical and coronal areas per second. The results were analyzed by repeated measures ANOVA considering the laser power as between-subject variable.

Results: There was a temperature increase in the coronal and apical areas in use of 1 W power. There was a temperature rise in the coronal and apical areas in use of 1.5 W power. The temperature rise in the apical third was more than that in the coronal third; also, the average temperature rise was more in use of 1.5 W power than 1 W power.

Conclusions: As the average temperature increase was not more than 7°C in any group, this type of laser seems to be suitable for root treatment of primary anterior teeth.

Abstract Image

Abstract Image

Abstract Image

Er:YAG激光除牙术中前乳牙根面热变化的研究。
目的:根管治疗的成功与否取决于根管内微生物的清除。考虑到常规方法不能完全去除根管中的细菌,激光被认为是一种新的方法。尽管激光具有抗菌特性,但它也会引起热变化。本研究评估了Er:YAG激光在乳牙除牙术中根表面的热变化。材料与方法:收集60颗乳牙,用k锉制备50颗乳牙。然后随机分为两组,用Er:YAG激光照射。第一组用1w激光照射,第二组用1.5 W激光照射。两组激光照射时间均为两个10秒周期,间隔2秒。热的变化是由温度计在根尖和冠状区域每秒测量。将激光功率作为受试者间变量,采用重复测量方差分析方法对结果进行分析。结果:使用1w功率时,冠状区和根尖区温度升高。在1.5 W的功率下,冠状区和根尖区温度升高。顶端三分之一的温升大于冠状三分之一;使用1.5 W功率时的平均温升高于使用1 W功率时的平均温升。结论:各组平均温升均不超过7°C,适合于前牙根部治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
24 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信