{"title":"Effect of a Novel Photoelectrochemical Oxidation Air Purifier on Nasal and Ocular Allergy Symptoms.","authors":"Nikhil G Rao, Ambuj Kumar, Jenny S Wong, Ravi Shridhar, Dharendra Y Goswami","doi":"10.1177/2152656718781609","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Photoelectrochemical oxidation (PECO) is a new air purification technology developed to reduce circulating indoor allergens. PECO removes particles as small as 0.1 nm with the destruction of organic matter otherwise not trapped by a traditional filter and removes volatile organic compounds.</p><p><strong>Objective: </strong>We hypothesized that with daily use, the device would reduce user nasal and ocular allergy total symptom scores (TSS) within 4 weeks.</p><p><strong>Methods: </strong>The study was performed among 46 individuals with self-reported allergies using a portable PECO air purifier. Self-reported TSS were calculated at baseline and weekly for 4 weeks following initiation of continuous use of the system. TSS was the sum of total nasal symptom scores (TNSS) and total ocular symptom scores (TOSS) for the week.</p><p><strong>Results: </strong>There was a statistically significant change in overall TSS from baseline to 4 weeks (10.1 at baseline and 4.35 postintervention) resulting in a mean difference of 5.75 (95% confidence interval [CI] 4.32-7.18; <i>P</i> < .0001). There was a statistically significant change in TNSS from baseline to 4 weeks (6.3 at baseline and 3.04 postintervention) resulting in a mean difference of 3.26 (95% CI 2.33-3.19; <i>P</i> < .0001). There was a statistically significant change in TOSS from baseline to 4 weeks (3.82 at baseline and 1.3 postintervention) resulting in a mean difference of 2.52 (95% CI 1.74-3.3; <i>P</i> < .0001).</p><p><strong>Conclusion: </strong>With the use of PECO air purification technology, TSS, TNSS, and TOSS decreased significantly. These improvements were consistent over the 4-week course of device use.</p>","PeriodicalId":45192,"journal":{"name":"Allergy & Rhinology","volume":"9 ","pages":"2152656718781609"},"PeriodicalIF":2.3000,"publicationDate":"2018-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/2152656718781609","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Allergy & Rhinology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/2152656718781609","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 8
Abstract
Background: Photoelectrochemical oxidation (PECO) is a new air purification technology developed to reduce circulating indoor allergens. PECO removes particles as small as 0.1 nm with the destruction of organic matter otherwise not trapped by a traditional filter and removes volatile organic compounds.
Objective: We hypothesized that with daily use, the device would reduce user nasal and ocular allergy total symptom scores (TSS) within 4 weeks.
Methods: The study was performed among 46 individuals with self-reported allergies using a portable PECO air purifier. Self-reported TSS were calculated at baseline and weekly for 4 weeks following initiation of continuous use of the system. TSS was the sum of total nasal symptom scores (TNSS) and total ocular symptom scores (TOSS) for the week.
Results: There was a statistically significant change in overall TSS from baseline to 4 weeks (10.1 at baseline and 4.35 postintervention) resulting in a mean difference of 5.75 (95% confidence interval [CI] 4.32-7.18; P < .0001). There was a statistically significant change in TNSS from baseline to 4 weeks (6.3 at baseline and 3.04 postintervention) resulting in a mean difference of 3.26 (95% CI 2.33-3.19; P < .0001). There was a statistically significant change in TOSS from baseline to 4 weeks (3.82 at baseline and 1.3 postintervention) resulting in a mean difference of 2.52 (95% CI 1.74-3.3; P < .0001).
Conclusion: With the use of PECO air purification technology, TSS, TNSS, and TOSS decreased significantly. These improvements were consistent over the 4-week course of device use.