LVIS Jr Device for Y-Stent-Assisted Coil Embolization of Wide-Neck Intracranial Aneurysms: A Multicenter Experience.

Q1 Medicine
Interventional Neurology Pub Date : 2018-04-01 Epub Date: 2018-04-03 DOI:10.1159/000487545
Edgar A Samaniego, Aldo A Mendez, Thanh N Nguyen, Vladimir Kalousek, Waldo R Guerrero, Sudeepta Dandapat, Guilherme Dabus, Italo Linfante, Ameer E Hassan, Alexander Drofa, Evgueni Kouznetsov, David Leedahl, David Hasan, Alberto Maud, Santiago Ortega-Gutierrez
{"title":"LVIS Jr Device for Y-Stent-Assisted Coil Embolization of Wide-Neck Intracranial Aneurysms: A Multicenter Experience.","authors":"Edgar A Samaniego,&nbsp;Aldo A Mendez,&nbsp;Thanh N Nguyen,&nbsp;Vladimir Kalousek,&nbsp;Waldo R Guerrero,&nbsp;Sudeepta Dandapat,&nbsp;Guilherme Dabus,&nbsp;Italo Linfante,&nbsp;Ameer E Hassan,&nbsp;Alexander Drofa,&nbsp;Evgueni Kouznetsov,&nbsp;David Leedahl,&nbsp;David Hasan,&nbsp;Alberto Maud,&nbsp;Santiago Ortega-Gutierrez","doi":"10.1159/000487545","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong>Complex wide-neck intracranial aneurysms are challenging to treat. We report a multicenter experience using the LVIS Jr stent for \"Y-stent\"-assisted coiling embolization of wide-neck bifurcation aneurysms.</p><p><strong>Methods: </strong>Seven centers provided retrospective data on patients who underwent Y-stenting. Technical complications, immediate posttreatment angiographic results, clinical outcomes, and imaging follow-up were assessed.</p><p><strong>Results: </strong>Thirty patients/aneurysms were treated: 15 basilar tip, 8 middle cerebral artery, 4 anterior communicating artery, 1 pericallosal, and 2 posterior inferior cerebellar artery aneurysms. The mean aneurysm size was 11 mm and the mean dome-to-neck ratio was 1.3 mm. Twenty-four aneurysms were unruptured and treated electively, and 6 were acutely ruptured. Fifty-eight LVIS Jr stents were successfully deployed without any technical issue. One pro-cedural and transient in-stent thrombosis resolved with the intravenous infusion of a glycoprotein IIb/IIIa inhibitor. Five periprocedural complications (within 30 days) occurred: 2 periprocedural neurological complications (1 small temporal stroke that presented with transient aphasia and 1 posterior cerebral artery infarct) and 3 nonneurological periprocedural complications (2 retroperitoneal hematomas, and 1 patient developed a disseminated intravascular coagulopathy). One permanent complication (3.3%) directly related to Y-stenting was reported in the patient who suffered the posterior cerebral artery infarct. Immediate complete obliteration (Raymond-Roy Occlusion Classification [RROC] I-II) was achieved in 26 cases (89.6%). Twenty-four patients had clinical and imaging follow-up (mean 5.2 months). Complete angiographic occlusion (RROC I-II) was observed in 23 patients (96%). A good functional outcome with a modified Rankin Scale score ≤2 was achieved in 26 cases.</p><p><strong>Conclusions: </strong>In this multicenter case series, Y-stent-assisted coiling of wide-neck aneurysms with the LVIS Jr device was feasible and relatively safe. Follow-up imaging demonstrated very low recanalization rates.</p>","PeriodicalId":46280,"journal":{"name":"Interventional Neurology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000487545","citationCount":"37","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neurology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000487545","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/4/3 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 37

Abstract

Background and purpose: Complex wide-neck intracranial aneurysms are challenging to treat. We report a multicenter experience using the LVIS Jr stent for "Y-stent"-assisted coiling embolization of wide-neck bifurcation aneurysms.

Methods: Seven centers provided retrospective data on patients who underwent Y-stenting. Technical complications, immediate posttreatment angiographic results, clinical outcomes, and imaging follow-up were assessed.

Results: Thirty patients/aneurysms were treated: 15 basilar tip, 8 middle cerebral artery, 4 anterior communicating artery, 1 pericallosal, and 2 posterior inferior cerebellar artery aneurysms. The mean aneurysm size was 11 mm and the mean dome-to-neck ratio was 1.3 mm. Twenty-four aneurysms were unruptured and treated electively, and 6 were acutely ruptured. Fifty-eight LVIS Jr stents were successfully deployed without any technical issue. One pro-cedural and transient in-stent thrombosis resolved with the intravenous infusion of a glycoprotein IIb/IIIa inhibitor. Five periprocedural complications (within 30 days) occurred: 2 periprocedural neurological complications (1 small temporal stroke that presented with transient aphasia and 1 posterior cerebral artery infarct) and 3 nonneurological periprocedural complications (2 retroperitoneal hematomas, and 1 patient developed a disseminated intravascular coagulopathy). One permanent complication (3.3%) directly related to Y-stenting was reported in the patient who suffered the posterior cerebral artery infarct. Immediate complete obliteration (Raymond-Roy Occlusion Classification [RROC] I-II) was achieved in 26 cases (89.6%). Twenty-four patients had clinical and imaging follow-up (mean 5.2 months). Complete angiographic occlusion (RROC I-II) was observed in 23 patients (96%). A good functional outcome with a modified Rankin Scale score ≤2 was achieved in 26 cases.

Conclusions: In this multicenter case series, Y-stent-assisted coiling of wide-neck aneurysms with the LVIS Jr device was feasible and relatively safe. Follow-up imaging demonstrated very low recanalization rates.

Abstract Image

Abstract Image

Abstract Image

LVIS Jr装置用于y型支架辅助线圈栓塞治疗宽颈颅内动脉瘤:多中心经验。
背景与目的:复杂的宽颈颅内动脉瘤治疗具有挑战性。我们报告使用LVIS Jr支架进行“y支架”辅助的宽颈分叉动脉瘤的多中心栓塞治疗的经验。方法:7个中心提供了接受y型支架植入术患者的回顾性资料。评估技术并发症、治疗后立即血管造影结果、临床结果和影像学随访。结果:共治疗30例动脉瘤,其中颅底尖端动脉瘤15例,大脑中动脉动脉瘤8例,前交通动脉动脉瘤4例,胼胝体周围动脉瘤1例,小脑后下动脉动脉瘤2例。动脉瘤的平均大小为11mm,平均穹颈比为1.3 mm。24例动脉瘤未破裂,选择性治疗,6例急性破裂。58个LVIS Jr支架成功部署,没有任何技术问题。一例硬膜前和支架内短暂血栓通过静脉输注糖蛋白IIb/IIIa抑制剂得以缓解。发生5例围手术期并发症(30天内):2例围手术期神经系统并发症(1例小颞叶卒中伴一过性失语,1例脑后动脉梗死),3例非神经系统围手术期并发症(2例腹膜后血肿,1例发生弥散性血管内凝血病)。脑后动脉梗死患者报告了1例与y型支架直接相关的永久性并发症(3.3%)。即刻完全闭塞(Raymond-Roy Occlusion Classification [RROC] I-II) 26例(89.6%)。24例患者接受临床及影像学随访(平均5.2个月)。23例患者(96%)出现完全血管造影闭塞(RROC I-II)。26例功能预后良好,改良Rankin量表评分≤2分。结论:在本多中心病例系列中,使用LVIS Jr装置进行y型支架辅助的宽颈动脉瘤卷取是可行且相对安全的。随访影像显示再通率非常低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Interventional Neurology
Interventional Neurology CLINICAL NEUROLOGY-
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信