An update work of pulse oximetry screening for detecting critical congenital heart disease in the newborn.

Images in paediatric cardiology Pub Date : 2017-07-01
A Taksande, R Meshram, A Lohakare, S Purandare, U Biyani, J Vagha
{"title":"An update work of pulse oximetry screening for detecting critical congenital heart disease in the newborn.","authors":"A Taksande,&nbsp;R Meshram,&nbsp;A Lohakare,&nbsp;S Purandare,&nbsp;U Biyani,&nbsp;J Vagha","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Congenital Heart Disease (CHD) is the commonest group of congenital malformations and affects 7-8 per 1000 live born newborns. Nevertheless, it is estimated that more than 50% of babies with undiagnosed CHD are not detected by routine neonatal cardiac examination.</p><p><strong>Aim: </strong>To find the incidence of CHD in newborns and to determine the accuracy of pulse oximetry for detecting clinically unrecognized critical congenital heart disease (CCHD) in the newborns.</p><p><strong>Methods: </strong>Pulse oximetry was performed on clinically normal newborns within 4 hours of first day of life. Inclusion criteria: All newborns who were admitted in postnatal ward & Neonatal Intensive care unit (NICU). Exclusion criteria: babies and neonates with a prenatal diagnosis of duct dependent circulation. If oxygen saturation (SpO<sub>2</sub>) was below 90%, then echocardiography was performed.</p><p><strong>Results: </strong>During the study period, 4926 live born neonates were examined. Nine out of 12 neonates with SpO2<90% had CCHD. Four neonates had tetralogy of Fallot (TOF), two had tricuspid atresia, two had transposition of great arteries (TGA) and one had truncus arteriosus. The incidence of CHD was 33.49 per 1000 live births and CCHD was 1.82 per 1000.  A pulse oximetry cut-off value of below 90% for detecting CCHD showed 90% sensitivity, 99.94% specificity, 75% positive predictive value (PPV) and 99.98% negative predictive value (NPV).</p><p><strong>Conclusion: </strong>Pulse oximetry is safe, feasible and noninvasive and also used to screen for CCHD. It is the nice method to detect the CHD along with the physical examination of neonates by medical personal.</p>","PeriodicalId":89564,"journal":{"name":"Images in paediatric cardiology","volume":"19 3","pages":"12-18"},"PeriodicalIF":0.0000,"publicationDate":"2017-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5917867/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Images in paediatric cardiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Congenital Heart Disease (CHD) is the commonest group of congenital malformations and affects 7-8 per 1000 live born newborns. Nevertheless, it is estimated that more than 50% of babies with undiagnosed CHD are not detected by routine neonatal cardiac examination.

Aim: To find the incidence of CHD in newborns and to determine the accuracy of pulse oximetry for detecting clinically unrecognized critical congenital heart disease (CCHD) in the newborns.

Methods: Pulse oximetry was performed on clinically normal newborns within 4 hours of first day of life. Inclusion criteria: All newborns who were admitted in postnatal ward & Neonatal Intensive care unit (NICU). Exclusion criteria: babies and neonates with a prenatal diagnosis of duct dependent circulation. If oxygen saturation (SpO2) was below 90%, then echocardiography was performed.

Results: During the study period, 4926 live born neonates were examined. Nine out of 12 neonates with SpO2<90% had CCHD. Four neonates had tetralogy of Fallot (TOF), two had tricuspid atresia, two had transposition of great arteries (TGA) and one had truncus arteriosus. The incidence of CHD was 33.49 per 1000 live births and CCHD was 1.82 per 1000.  A pulse oximetry cut-off value of below 90% for detecting CCHD showed 90% sensitivity, 99.94% specificity, 75% positive predictive value (PPV) and 99.98% negative predictive value (NPV).

Conclusion: Pulse oximetry is safe, feasible and noninvasive and also used to screen for CCHD. It is the nice method to detect the CHD along with the physical examination of neonates by medical personal.

Abstract Image

Abstract Image

脉搏血氧仪筛查新生儿危重先天性心脏病的最新进展。
背景:先天性心脏病(CHD)是最常见的先天性畸形,每1000名活产新生儿中有7-8例。然而,据估计,超过50%的未确诊冠心病的婴儿未被常规新生儿心脏检查发现。目的:了解新生儿冠心病的发病率,探讨脉搏血氧仪检测新生儿临床未识别的危重型先天性心脏病(CCHD)的准确性。方法:对临床正常新生儿在出生第一天4小时内进行脉搏血氧测定。纳入标准:所有在产后病房和新生儿重症监护病房(NICU)住院的新生儿。排除标准:产前诊断为导管依赖循环的婴儿和新生儿。若血氧饱和度(SpO2)低于90%,则行超声心动图检查。结果:研究期间共检查4926例活产新生儿。结论:脉搏血氧仪安全、可行、无创,可用于CCHD筛查。医务人员对新生儿进行体格检查,是一种较好的检测冠心病的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书