{"title":"The first case of the Reveal LINQ™ Insertable Cardiac Monitor implanted in a child in Malta.","authors":"A Aquilina,&nbsp;O Aquilina,&nbsp;M Sammut,&nbsp;V Grech","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The Reveal LINQ™Insertable Cardiac Monitor (ICM) or Implantable Loop recorder (ILR), is a miniaturized, subcutaneous, single lead, electrocardiographic monitoring device which has been extensively used in the differential diagnosis of unexplained syncope and palpitations in adults.</p><p><strong>Patient description: </strong>We describe an asymptomatic 20-month-old boy, noted to have incidental bradycardia on routine examination and in whom Holter monitoring revealed complete heart block (CHB). Over 1 year, the longest recorded pause lengthened from 1.8 seconds to 3.6 seconds.</p><p><strong>Results: </strong>The Reveal LINQ™ ICM was inserted for long-term monitoring of the CHB. The device will record the electrocardiogram (ECG) continuously for up to 3 years, freezing in its memory any significant arrhythmic events. This will enable the diagnosis of the longest pauses, confirm whether they are lengthening over time and assist with the decision of pacemaker implantation.</p><p><strong>Conclusion: </strong>The Reveal LINQ™ ICM is much smaller than the conventional loop recorder and has been shown to be ideal for close monitoring of asymptomatic yet potentially dangerous arrhythmias in young children.</p>","PeriodicalId":89564,"journal":{"name":"Images in paediatric cardiology","volume":"19 4","pages":"10-21"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5917869/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Images in paediatric cardiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The Reveal LINQ™Insertable Cardiac Monitor (ICM) or Implantable Loop recorder (ILR), is a miniaturized, subcutaneous, single lead, electrocardiographic monitoring device which has been extensively used in the differential diagnosis of unexplained syncope and palpitations in adults.

Patient description: We describe an asymptomatic 20-month-old boy, noted to have incidental bradycardia on routine examination and in whom Holter monitoring revealed complete heart block (CHB). Over 1 year, the longest recorded pause lengthened from 1.8 seconds to 3.6 seconds.

Results: The Reveal LINQ™ ICM was inserted for long-term monitoring of the CHB. The device will record the electrocardiogram (ECG) continuously for up to 3 years, freezing in its memory any significant arrhythmic events. This will enable the diagnosis of the longest pauses, confirm whether they are lengthening over time and assist with the decision of pacemaker implantation.

Conclusion: The Reveal LINQ™ ICM is much smaller than the conventional loop recorder and has been shown to be ideal for close monitoring of asymptomatic yet potentially dangerous arrhythmias in young children.

Abstract Image

Abstract Image

Abstract Image

首例Reveal LINQ™可插入式心脏监护仪植入马耳他儿童体内。
背景:Reveal LINQ™可插入心脏监测器(ICM)或植入式环路记录仪(ILR)是一种小型化的皮下单导联心电图监测设备,已广泛用于成人不明原因晕厥和心悸的鉴别诊断。患者描述:我们描述了一个无症状的20个月大的男孩,在常规检查中注意到偶然的心动过缓,霍尔特监测显示完全心脏传导阻滞(CHB)。在1年的时间里,记录的最长停顿从1.8秒延长到3.6秒。结果:插入Reveal LINQ™ICM用于长期监测CHB。该设备将连续记录心电图(ECG)长达3年,并将任何显著的心律失常事件冻结在其记忆中。这将有助于诊断最长的停顿,确认它们是否随着时间的推移而延长,并有助于决定是否植入起搏器。结论:Reveal LINQ™ICM比传统的循环记录仪小得多,已被证明是密切监测幼儿无症状但有潜在危险的心律失常的理想选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书