Immediate, early (6 weeks) and delayed loading (3 months) of single, partial and full fixed implant supported prostheses: 1-year post-loading data from a multicentre randomised controlled trial.
Miltiadis Mitsias, Konstantinos Siormpas, Valeria Pistilli, Anna Trullenque-Eriksson, Marco Esposito
{"title":"Immediate, early (6 weeks) and delayed loading (3 months) of single, partial and full fixed implant supported prostheses: 1-year post-loading data from a multicentre randomised controlled trial.","authors":"Miltiadis Mitsias, Konstantinos Siormpas, Valeria Pistilli, Anna Trullenque-Eriksson, Marco Esposito","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the clinical outcome of single, partial and complete fixed implant supported prostheses immediately loaded (within 48 h), early loaded at 6 weeks, and conventionally loaded at 3 months (delayed loading).</p><p><strong>Materials and methods: </strong>A total of 54 patients (18 requiring single implants, 18 partial fixed prostheses, and 18 total fixed cross-arch prostheses) were randomised in equal numbers at two private practices to immediate loading (18 patients), early loading (18 patients), and conventional loading (18 patients) according to a parallel group design with three arms. To be immediately or early loaded, implants had to be inserted with a torque superior to 40 Ncm. Implants were initially loaded with provisional prostheses, replaced after 4 months by definitive ones. Outcome measures were prosthesis and implant failures, complications and peri-implant marginal bone levels.</p><p><strong>Results: </strong>Two conventionally loaded patients rehabilitated with cross-arch fixed total prostheses dropped-out up to 1 year post-loading. No implant or prosthesis failed and three complications occurred, one in each loading group. Peri-implant marginal bone loss was 0.19 ± 0.44 mm at immediately loaded implants, 0.18 ± 0.66 mm at early loaded implants and 0.25 ± 0.28 mm at conventional loaded implants. There were no statistically significant differences in complications (P = 1.000) and bone loss (P = 0.806) between the three loading strategies.</p><p><strong>Conclusions: </strong>All loading strategies were highly successful and no differences could be observed for implant survival and complications when loading implants immediately, early or conventionally.</p>","PeriodicalId":49259,"journal":{"name":"European Journal of Oral Implantology","volume":"11 1","pages":"63-75"},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Oral Implantology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To compare the clinical outcome of single, partial and complete fixed implant supported prostheses immediately loaded (within 48 h), early loaded at 6 weeks, and conventionally loaded at 3 months (delayed loading).
Materials and methods: A total of 54 patients (18 requiring single implants, 18 partial fixed prostheses, and 18 total fixed cross-arch prostheses) were randomised in equal numbers at two private practices to immediate loading (18 patients), early loading (18 patients), and conventional loading (18 patients) according to a parallel group design with three arms. To be immediately or early loaded, implants had to be inserted with a torque superior to 40 Ncm. Implants were initially loaded with provisional prostheses, replaced after 4 months by definitive ones. Outcome measures were prosthesis and implant failures, complications and peri-implant marginal bone levels.
Results: Two conventionally loaded patients rehabilitated with cross-arch fixed total prostheses dropped-out up to 1 year post-loading. No implant or prosthesis failed and three complications occurred, one in each loading group. Peri-implant marginal bone loss was 0.19 ± 0.44 mm at immediately loaded implants, 0.18 ± 0.66 mm at early loaded implants and 0.25 ± 0.28 mm at conventional loaded implants. There were no statistically significant differences in complications (P = 1.000) and bone loss (P = 0.806) between the three loading strategies.
Conclusions: All loading strategies were highly successful and no differences could be observed for implant survival and complications when loading implants immediately, early or conventionally.