Rozaliia F Solodova, Vladimir V Galatenko, Eldar R Nakashidze, Sergey G Shapovalyants, Igor L Andreytsev, Mikhail E Sokolov, Vladimir E Podolskii
{"title":"Instrumental Mechanoreceptoric Palpation in Gastrointestinal Surgery.","authors":"Rozaliia F Solodova, Vladimir V Galatenko, Eldar R Nakashidze, Sergey G Shapovalyants, Igor L Andreytsev, Mikhail E Sokolov, Vladimir E Podolskii","doi":"10.1155/2017/6481856","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>Small gastric or colorectal tumours can be visually undetectable during laparoscopic surgeries, and available methods still do not provide a 100% localisation rate. Thus, new methods for further improvements in tumour localisation are highly desirable. In this study, we evaluated the usage of the Medical Tactile Endosurgical Complex (MTEC) in gastrointestinal surgery for localisation of tumours. The MTEC provides the possibility of instrumental mechanoreceptoric palpation, which serves as an analogue of conventional manual palpation.</p><p><strong>Methods: </strong>Ninety-six elective surgeries were performed, including 48 open surgeries, 43 laparoscopies, and 5 robot-assisted surgeries. The 20 mm version of the MTEC tactile mechanoreceptor was used in open surgeries, and the 10 mm version in laparoscopic and robot-assisted surgeries.</p><p><strong>Results: </strong>The mean time of instrumental mechanoreceptoric palpation was 3 minutes 12 seconds for open surgeries, which constituted the early stage of the learning curve, and 3 minutes 34 seconds for laparoscopic surgeries. No side effects or postoperative complications related to instrumental mechanoreceptoric palpation were observed, and this procedure provided data sufficient for tumour localisation in more than 95% of cases.</p><p><strong>Conclusion: </strong>Instrumental mechanoreceptoric palpation performed using MTEC is a simple, safe, and reliable method for tumour localisation in gastrointestinal laparoscopic surgery.</p>","PeriodicalId":45110,"journal":{"name":"Minimally Invasive Surgery","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2017/6481856","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minimally Invasive Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2017/6481856","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/12/31 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 7
Abstract
Background and aims: Small gastric or colorectal tumours can be visually undetectable during laparoscopic surgeries, and available methods still do not provide a 100% localisation rate. Thus, new methods for further improvements in tumour localisation are highly desirable. In this study, we evaluated the usage of the Medical Tactile Endosurgical Complex (MTEC) in gastrointestinal surgery for localisation of tumours. The MTEC provides the possibility of instrumental mechanoreceptoric palpation, which serves as an analogue of conventional manual palpation.
Methods: Ninety-six elective surgeries were performed, including 48 open surgeries, 43 laparoscopies, and 5 robot-assisted surgeries. The 20 mm version of the MTEC tactile mechanoreceptor was used in open surgeries, and the 10 mm version in laparoscopic and robot-assisted surgeries.
Results: The mean time of instrumental mechanoreceptoric palpation was 3 minutes 12 seconds for open surgeries, which constituted the early stage of the learning curve, and 3 minutes 34 seconds for laparoscopic surgeries. No side effects or postoperative complications related to instrumental mechanoreceptoric palpation were observed, and this procedure provided data sufficient for tumour localisation in more than 95% of cases.
Conclusion: Instrumental mechanoreceptoric palpation performed using MTEC is a simple, safe, and reliable method for tumour localisation in gastrointestinal laparoscopic surgery.