Motion-Robust Spatially Constrained Parameter Estimation in Renal Diffusion-Weighted MRI by 3D Motion Tracking and Correction of Sequential Slices.

Sila Kurugol, Bahram Marami, Onur Afacan, Simon K Warfield, Ali Gholipour
{"title":"Motion-Robust Spatially Constrained Parameter Estimation in Renal Diffusion-Weighted MRI by 3D Motion Tracking and Correction of Sequential Slices.","authors":"Sila Kurugol,&nbsp;Bahram Marami,&nbsp;Onur Afacan,&nbsp;Simon K Warfield,&nbsp;Ali Gholipour","doi":"10.1007/978-3-319-67564-0_8","DOIUrl":null,"url":null,"abstract":"<p><p>In this work, we introduce a novel motion-robust spatially constrained parameter estimation (MOSCOPE) technique for kidney diffusion-weighted MRI. The proposed motion compensation technique does not require a navigator, trigger, or breath-hold but only uses the intrinsic features of the acquired data to track and compensate for motion to reconstruct precise models of the renal diffusion signal. We have developed a technique for physiological motion tracking based on robust state estimation and sequential registration of diffusion sensitized slices acquired within 200ms. This allows a sampling rate of 5Hz for state estimation in motion tracking that is sufficiently faster than both respiratory and cardiac motion rates in children and adults, which range between 0.8 to 0.2Hz, and 2.5 to 1Hz, respectively. We then apply the estimated motion parameters to data from each slice and use motion-compensated data for 1) robust intra-voxel incoherent motion (IVIM) model estimation in the kidney using a spatially constrained model fitting approach, and 2) robust weighted least squares estimation of the diffusion tensor model. Experimental results, including precision of IVIM model parameters using bootstrap-sampling and <i>in-vivo</i> whole kidney tractography, showed significant improvement in precision and accuracy of these models using the proposed method compared to models based on the original data and volumetric registration.</p>","PeriodicalId":92268,"journal":{"name":"Molecular imaging, reconstruction and analysis of moving body organs, and stroke imaging and treatment : Fifth International Workshop, CMMI 2017, Second International Workshop, RAMBO 2017, and First International Workshop, SWITCH 2017, ...","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/978-3-319-67564-0_8","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Molecular imaging, reconstruction and analysis of moving body organs, and stroke imaging and treatment : Fifth International Workshop, CMMI 2017, Second International Workshop, RAMBO 2017, and First International Workshop, SWITCH 2017, ...","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/978-3-319-67564-0_8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/9/9 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

In this work, we introduce a novel motion-robust spatially constrained parameter estimation (MOSCOPE) technique for kidney diffusion-weighted MRI. The proposed motion compensation technique does not require a navigator, trigger, or breath-hold but only uses the intrinsic features of the acquired data to track and compensate for motion to reconstruct precise models of the renal diffusion signal. We have developed a technique for physiological motion tracking based on robust state estimation and sequential registration of diffusion sensitized slices acquired within 200ms. This allows a sampling rate of 5Hz for state estimation in motion tracking that is sufficiently faster than both respiratory and cardiac motion rates in children and adults, which range between 0.8 to 0.2Hz, and 2.5 to 1Hz, respectively. We then apply the estimated motion parameters to data from each slice and use motion-compensated data for 1) robust intra-voxel incoherent motion (IVIM) model estimation in the kidney using a spatially constrained model fitting approach, and 2) robust weighted least squares estimation of the diffusion tensor model. Experimental results, including precision of IVIM model parameters using bootstrap-sampling and in-vivo whole kidney tractography, showed significant improvement in precision and accuracy of these models using the proposed method compared to models based on the original data and volumetric registration.

Abstract Image

Abstract Image

Abstract Image

基于三维运动跟踪和序列切片校正的肾弥散加权MRI运动鲁棒空间约束参数估计。
在这项工作中,我们介绍了一种新的运动鲁棒空间约束参数估计(MOSCOPE)技术,用于肾脏弥散加权MRI。所提出的运动补偿技术不需要导航器、触发器或屏气,而是仅使用所获取数据的固有特征来跟踪和补偿运动,以重建肾脏弥散信号的精确模型。我们已经开发了一种基于鲁棒状态估计和在200ms内获得的扩散敏化切片的顺序配准的生理运动跟踪技术。这允许5Hz的采样率用于运动跟踪中的状态估计,这比儿童和成人的呼吸和心脏运动速率(分别在0.8至0.2Hz和2.5至1Hz之间)快得多。然后,我们将估计的运动参数应用于来自每个切片的数据,并使用运动补偿数据进行1)使用空间约束模型拟合方法对肾脏的体素内非相干运动(IVIM)模型进行鲁棒估计,以及2)对扩散张量模型进行鲁棒加权最小二乘估计。实验结果显示,与基于原始数据和体积配准的模型相比,采用该方法获得的IVIM模型参数精度有了显著提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信