Comparison of the Dentin Bond Strength of Two Self-Etch Adhesives After Prolonged Air-Drying and Additional Light-Curing.

Pouran Samimi, Masoud Ghodrati, Farinaz Shirban, Maryam Khoroushi
{"title":"Comparison of the Dentin Bond Strength of Two Self-Etch Adhesives After Prolonged Air-Drying and Additional Light-Curing.","authors":"Pouran Samimi,&nbsp;Masoud Ghodrati,&nbsp;Farinaz Shirban,&nbsp;Maryam Khoroushi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>It has been reported that the water, solvents, or the primer incorporated into adhesive resins decrease the polymerization, compromise the mechanical properties, reduce the bond strength, and lead to a poor bonding performance of self-etch adhesives. This article evaluated the effect of air-drying and light-curing duration of self-etch adhesives on the micro-shear bond strength between composite resin and dentin.</p><p><strong>Materials and methods: </strong>A total of 120 extracted sound human third molars were randomly divided into twelve groups (n=10). The occlusal dentin in each tooth was exposed. Clearfil SE Bond (CSEB) and Clearfil S3 Bond (CS3B) were used according to the manufacturer's instructions, followed by air-drying for 3 and 10 seconds in different groups. The adhesives were light-cured for 10, 20 and 40 seconds in different subgroups. Next, the composite resin (Clearfil AP-X) was placed on the dentin surface and was polymerized for 40 seconds. The micro-shear bond strength values were determined using a universal testing machine, and the results were statistically analyzed by three-way ANOVA and Tukey's post-hoc test (α=0.05).</p><p><strong>Results: </strong>CSEB exhibited a significantly higher dentin bond strength than CS3B. Increasing the curing time of CSEB resulted in an increase in the bond strength, whereas an increase in the air-drying time did not affect the bond strength of the two adhesives.</p><p><strong>Conclusions: </strong>Within the limitations of this study, an increase in the curing time improved the bond strength of CSEB, whereas the air-drying time did not affect the bond strength of the evaluated adhesives.</p>","PeriodicalId":30286,"journal":{"name":"Journal of Dentistry of Tehran University of Medical Sciences","volume":" ","pages":"292-298"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5748457/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dentistry of Tehran University of Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: It has been reported that the water, solvents, or the primer incorporated into adhesive resins decrease the polymerization, compromise the mechanical properties, reduce the bond strength, and lead to a poor bonding performance of self-etch adhesives. This article evaluated the effect of air-drying and light-curing duration of self-etch adhesives on the micro-shear bond strength between composite resin and dentin.

Materials and methods: A total of 120 extracted sound human third molars were randomly divided into twelve groups (n=10). The occlusal dentin in each tooth was exposed. Clearfil SE Bond (CSEB) and Clearfil S3 Bond (CS3B) were used according to the manufacturer's instructions, followed by air-drying for 3 and 10 seconds in different groups. The adhesives were light-cured for 10, 20 and 40 seconds in different subgroups. Next, the composite resin (Clearfil AP-X) was placed on the dentin surface and was polymerized for 40 seconds. The micro-shear bond strength values were determined using a universal testing machine, and the results were statistically analyzed by three-way ANOVA and Tukey's post-hoc test (α=0.05).

Results: CSEB exhibited a significantly higher dentin bond strength than CS3B. Increasing the curing time of CSEB resulted in an increase in the bond strength, whereas an increase in the air-drying time did not affect the bond strength of the two adhesives.

Conclusions: Within the limitations of this study, an increase in the curing time improved the bond strength of CSEB, whereas the air-drying time did not affect the bond strength of the evaluated adhesives.

Abstract Image

Abstract Image

两种自蚀刻胶粘剂在长时间风干和额外光固化后牙本质结合强度的比较。
目的:有报道称,自蚀刻胶粘剂中掺入的水、溶剂或底漆会降低自蚀刻胶粘剂的聚合,损害其机械性能,降低粘接强度,导致自蚀刻胶粘剂的粘接性能变差。研究了自蚀胶粘剂的风干时间和光固化时间对复合树脂与牙本质微剪切结合强度的影响。材料与方法:120颗拔除的健全人第三磨牙随机分为12组(n=10)。每颗牙的咬合牙本质暴露。clearfilse Bond (CSEB)和clearfils3 Bond (CS3B)按照制造商的说明使用,然后在不同的组中风干3秒和10秒。不同亚组的胶粘剂分别光固化10、20和40秒。接下来,将复合树脂(Clearfil AP-X)放置在牙本质表面,聚合40秒。采用万能试验机测定微剪切粘结强度值,采用三因素方差分析和Tukey事后检验对结果进行统计学分析(α=0.05)。结果:CSEB的牙本质结合强度明显高于CS3B。增加CSEB的固化时间会导致粘结强度的增加,而增加风干时间对两种胶粘剂的粘结强度没有影响。结论:在本研究的限制范围内,增加固化时间可以提高CSEB的结合强度,而风干时间对评价胶粘剂的结合强度没有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
24 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信